Eaton FDA332PER Lighting & Emergency Systems - 3-lamp 32W

Part Number: FDA332PER
Manufacturer
Eaton
Part number
FDA332PER

Quick Summary

FDA332PER is a rugged marine interior lighting fixture designed for recessed ceiling installations aboard ships and offshore equipment. It delivers reliable 3-lamp, 32W fluorescence across 120–277Vac and both 50 and 60 Hz power, addressing the common challenge of compatibility across international vessels. The unit carries NEC/CEC compliance and is suitable for Ordinary/Non-Hazardous Locations, supporting safe, compliant operation in general marine spaces. With a steel housing and acrylic lens, it resists corrosion and provides diffuse, glare-free illumination. For procurement and maintenance teams, its compatibility with the Pauluhn Meridian FDA family reduces spare-part inventories and speeds retrofits, while delivering consistent light levels and long-term life-cycle value.

Product Information

Extended Description

FDA332PER Eaton: Eaton Crouse-Hinds series Pauluhn Meridian FDA marine interior, 50/60 Hz, Acrylic lens, T8, Steel, Perpendicular, Recessed ceiling mount, 3-lamp, 120-277 Vac, 32W
Product Name
Eaton Crouse-Hinds series Pauluhn Meridian FDA marine interior
Catalog Number
FDA332PER
UPC
662276393813
Product Length/Depth
53.63 in
Product Height
4.13 in
Product Width
19.69 in
Product Weight
31 lb
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
Mounting direction
Perpendicular
Light type
T8
Number of lamps
3-lamp
Wattage
32W
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Mounting Method
Recessed ceiling
Material
Steel
Lens material
Acrylic
Feature: Recessed ceiling mounting with a steel housing and acrylic lens delivers a clean, low-profile installation that minimizes snag hazards in tight marine spaces. Impact: Reduces corrosion risk and simplifies cleaning and inspection, lowering maintenance costs over the life of the fixture. Application: Suited for cabin corridors, galleys, and other vessel interiors where a durable, glare-controlled T8 luminaire is required. Feature: 3-lamp 32W T8 fluorescent configuration provides broad coverage with balanced color and reliable operation. Impact: Delivers consistent lumen output across 50/60 Hz power and 120–277V supply, reducing the need for multiple part numbers. Application: Effective for general lighting in engine rooms and public areas on ships, offshore platforms, and remote fleets. Feature: Acrylic lens provides diffusion and impact resistance while resisting yellowing in humid environments. Impact: Maintains uniform illumination and reduces maintenance cycles related to replaceable lenses. Application: Particularly valuable in dirty or oily environments where glare control matters. Feature: NEC/CEC standard compliance and Ordinary/Non-Hazardous Locations classification. Impact: Ensures regulatory alignment and safe operation across international codes. Application: Purchase decisions for procurement teams needing compliant fixtures for standard shipboard spaces. Feature: Compatibility with Pauluhn Meridian FDA family for quick retrofits and lifecycle cost savings. Impact: Streamlines procurement and maintenance workflows, reducing downtime. Application: Fleet-wide retrofits in medium to large vessels. Feature: Long fixture length and weight support broad coverage and robust mounting. Impact: Simplifies layout planning and reduces the number of fixtures required per deck. Application: General corridor, engine room, and cargo hold lighting where 3-lamp 32W platforms are preferred.

Get a Quick Quote for a Eaton FDA332PER

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton FDA332PER? Enquire Now

FAQs

Install as a recessed ceiling luminaire using the perpendicular mounting method. Ensure a cutout matching the fixture length of 53.63 in and width of 19.69 in. Connect to 120–277Vac supply and verify 50/60 Hz compatibility. The fixture is designed to fit the Pauluhn Meridian FDA family for straightforward retrofits. This approach minimizes field wiring errors and ensures consistent lighting performance after installation.
The FDA332PER is listed with NEC/CEC standards and carries Ordinary/Non-Hazardous Locations classification. It uses a 120–277Vac supply, 50/60 Hz operation, 3-lamp 32W T8 configuration, and a steel housing with an acrylic lens to maintain safe, compliant operation in general marine spaces. This combination reduces procurement complexity and supports consistent performance across diverse fleets.
Yes. The fixture is classified for Ordinary/Non-Hazardous Locations and conforms to NEC/CEC standards, making it appropriate for standard shipboard spaces such as cabins and corridors without requiring hazardous-location approvals. This helps avoid costly rework during dock cycles and simplifies regulatory audits. Procurement teams value the predictable compliance profile for multi-vessel fleets.
53.63 inches in length, 19.69 inches in width, and 4.13 inches in height, with an approximate weight of 31 pounds, enabling predictable spacing and mounting on typical vessel ceilings. These exact measurements assist with ceiling cutouts, deck layout planning, and structural load calculations during vessel design and retrofits.
Downloads include IF LBL1485 installation instructions, the FDA332PER specification sheet, the Crouse-Hinds FDA Marine Interior catalog page, and the Pauluhn literature, all from Eaton's lighting literature library. If you need hard copies or CAD data, contact your Eaton representative for the latest files and formats.