Eaton Freedom Unitrol FDF2LM18 motor control center - UL Listed

Manufacturer
Eaton
Part number
FDF2LM18

Quick Summary

Eaton Freedom Unitrol motor control center enables compact, dual-feeder control for 100/125 A applications in industrial facilities. Plant teams face footprint limits, wiring complexity, and retrofit costs when upgrading older MCCs. UL Listed certification supports safety and reliable integration with Eaton design standards. This MCC aligns with standard panels, helping procurement simplify sourcing while reducing installation time. Designed for engineers and technicians, it enables scalable, compliant control for mid-size motors in manufacturing, water, and building automation. Its 18-inch unit size and dual feeder arrangement support compact layouts and faster maintenance planning. Overall, the Eaton Freedom Unitrol reduces total cost of ownership by simplifying inventory, installation, and spares management.

Product Information

Extended Description

FDF2LM18 Eaton: Eaton Freedom Unitrol motor control center, Freedom Unitrol Dual feeder Motor Control Center 100/125A trip rating, HFD circuit breaker, Dual feeder, Slider handle mechanism, 18-inch unit size
Product Name
Eaton Freedom Unitrol motor control center
Catalog Number
FDF2LM18
UPC
786685432434
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Slider handle
Size
18 in
Trip rating
100/125 A
Dual feeder with an HFD circuit breaker enables tailored load distribution and precise fault isolation. This arrangement reduces risk of cascading faults and minimizes downtime during commissioning or maintenance. It is well suited for mid-size motor loads on conveyors, pumps, and fans in manufacturing lines, water treatment, and building automation systems. Slider handle operation provides quick, safe access to internal components while maintaining secure interlocks and mechanical positioning. The ergonomic design reduces maintenance time, minimizes exposure to energized parts, and supports faster troubleshooting during routine servicing. This feature is especially valuable in plants with frequent motor starts, variable-speed drives, or cleanroom environments where access matters. Compact 18-inch unit size with 22 in depth, 25 in width, and 16 in height delivers a space-saving MCC footprint without compromising accessibility or wiring organization. The smaller footprint supports retrofits and panel upgrades in constrained electrical rooms or tight switchgear aisles, while preserving alignment with standard mounting patterns. Operators benefit from a clear, organized layout that improves wiring hygiene and future scalability. UL Listed certification underpins electrical safety and aligns with common industrial codes and commissioning practices. The unit supports a 100/125 A service rating and dual feeder configuration while maintaining reliable performance under load and fault conditions. This compliance simplifies approvals during plant audits and reduces engineering time for safety documentation. Standardization across the Eaton Freedom Unitrol line simplifies sourcing, maintenance planning, and spares management, reducing total cost of ownership across multiple sites. Installation is streamlined by consistent mounting patterns, interconnects, and accessory compatibility within the Freedom Unitrol family. For procurement and maintenance teams, this translates into predictable lead times, reduced vendor fragmentation, and easier long-term service planning.

Get a Quick Quote for a Eaton FDF2LM18

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton FDF2LM18? Enquire Now

FAQs

Begin by verifying the panel opening matches the 18 in unit footprint and confirm mounting clearance for the dual feeder configuration. Ensure proper wiring routing per the Eaton wiring diagram, secure the slider handle interlocks, and connect to the HFD circuit breaker. Verify torque specs and perform a functional test with protective relays coordinated to the system load profile.
Dual feeders provide flexible distribution to separate motor groups, enabling selective motor control and easier fault isolation. The HFD circuit breaker offers fast protection against overloads and short circuits, improving protective coordination and reducing downtime during faults. This setup is ideal for mid-size motor loads on conveyors, pumps, and fans in moderate-scale applications.
Yes, the FDF2LM18 is UL Listed, confirming conformance to recognized electrical safety standards. When installing, follow local electrical codes, plant safety guidelines, and Eaton's installation instructions. Ensure proper clearance, adherence to wiring diagrams, and routine maintenance documentation to support audits and regulatory compliance.
Key specs include a 100/125 A trip rating, HFD circuit breaker type, dual feeder configuration, slider handle operation, and an 18 in unit size. Dimensional footprint is 18 in width with overall panel dimensions of 22 in depth, 16 in height, and a unit weight of 33 lb. UPC: 786685432434 and catalog number FDF2LM18 are provided for ordering.
Upgrading to Freedom Unitrol MCCs standardizes components across sites, reducing spares variety and procurement lead times. Space-saving 18 in units enable denser installations, lowering floor space costs. Maintenance efficiency improves with slider-access panels and predictable installation practices, delivering faster commissioning and reduced downtime over the system's life cycle.