Eaton FIG 1001 2 1/2 X 1 FC SWBA PLN - OSHPD Certified
Part Number: FIG 1001 2 1/2 X 1 FC SWBA PLN
Quick Summary
The Eaton B-Line series TOLCO lateral sway brace attachment, FIG 1001, provides reliable lateral support for 2.5 inch pipe runs in seismic-rated installations. This helps prevent sway and misalignment that can jeopardize equipment, cables, and safety during seismic events. UL Listed and OSHPD Certified, the part meets critical code requirements for commercial and healthcare facilities, ensuring traceability and performance under load. By combining a plain steel finish with a compact profile, it simplifies field installs and reduces retrofit time. Designed for compatibility with Eaton’s catalogs and standard support systems, this sway brace brings predictable behavior, minimizes variation on site, and supports faster project delivery with reduced warranty risk.
Product Information
Extended Description
FIG 1001 2 1/2 X 1 FC SWBA PLN Eaton: Eaton B-Line series TOLCO lateral sway brace attachment, Plain, Steel, Fig 1001, 2.5" pipe size with 1" brace pipe, Sway brace attachment
Product Name
Eaton B-Line series TOLCO lateral sway brace attachment
Catalog Number
FIG 1001 2 1/2 X 1 FC SWBA PLN
UPC
782051720174
Product Length/Depth
0 in
Product Height
1 in
Product Width
0 in
Product Diameter
2.5 in
Product Weight
1.6 lb
Certifications
UL Listed OSHPD Certified
Finish
Plain
Material
Steel
Size
2.5 inch pipe size with 1 inch brace pipe
Model
Fig 1001
Type
Sway brace attachment
TOLCO seismic bracing overview brochure
TOLCO seismic bracing overview brochure
Seismic engineering guidelines
Seismic engineering guidelines
Eaton Specification Sheet - FIG 1001 2 1/2 X 1 FC SWBA PLN
Feature: Lateral sway brace attachment for 2.5 inch pipe with a 1 inch brace pipe. Business Impact: Provides robust seismic support with a compact footprint, reducing movement under load and improving system reliability. Application: Ideal for electrical and mechanical installations in constrained spaces. Feature: UL Listed and OSHPD Certified. Business Impact: Accelerates compliance reviews and mitigates regulatory risk for hospitals, data centers, and critical facilities. Application: Use in seismic bracing projects where code adherence is mandatory. Feature: Plain steel finish. Business Impact: Cost-effective material choice with straightforward maintenance and serviceability. Application: Retrofit and new builds requiring durable, plain-finish components. Feature: Fig 1001 designation and 2.5 inch pipe size with 1 inch brace. Business Impact: Standardized hardware supports predictable installation and interchangeability across Eaton catalogs. Application: Projects leveraging B-Line TOLCO seismic bracing systems. Feature: Compatibility with installation resources and engineering guidelines. Business Impact: Reduces design time and on-site errors, improving project throughput. Application: Engage with downloadable brochures and specification sheets for detailing and field assembly. Long-tail keywords integrated: seismic bracing for electrical enclosures, 2.5 inch pipe sway attachment, OSHPD seismic certification, UL listed sway brace, field retrofit of support systems, TOLCO seismic bracing system.
Get a Quick Quote for a Eaton FIG 1001 2 1/2 X 1 FC SWBA PLN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FIG 1001 2 1/2 X 1 FC SWBA PLN?
Enquire Now
FAQs
FIG 1001 SWBA PLN is designed to integrate with Eaton B-Line TOLCO support systems. Begin by verifying pipe size compatibility (2.5 in with a 1 in brace pipe) and ensuring the plain steel finish matches the installation. Secure the sway brace to the supporting structure per the seismic bracing guidelines, then align with adjacent supports to minimize rotation and lateral movement. The process is straightforward for retrofit and new builds, reducing field complexity and commissioning time.
Key specs include 2.5 inch pipe size with a 1 inch brace pipe, finished in plain steel, weight of 1.6 lb, and a height of 1 inch. Catalog number is FIG 1001 2 1/2 X 1 FC SWBA PLN. The part is UL Listed and OSHPD Certified, indicating compliance with major seismic and safety standards. These details guide proper selection and install integrity in critical facilities.
Yes. The FIG 1001 SWBA PLN is UL Listed and OSHPD Certified, making it suitable for seismic bracing in healthcare environments where regulatory compliance and dependable performance are essential. Its 2.5 in pipe size with a 1 in brace supports robust lateral restraint for critical electrical and mechanical distributions, aligning with hospital design and retrofit requirements.
The part carries UL Listed and OSHPD Certified statuses. UL Listing confirms electrical safety performance, while OSHPD certification ensures compliance with California seismic standards for building infrastructure. These certifications reduce design risk, speed approvals, and support reliable performance in seismically active regions.
Eaton provides downloadable assets including seismic bracing brochures, engineering guidelines, and a specification sheet. Access to Seismic engineering guidelines and the Seismic bracing catalog improves design accuracy and reduces change orders. The combination of certified hardware and these resources supports faster installation, lower maintenance, and a clearer path to compliant, cost-effective projects.