Eaton FJF2BM14 Motor Control Center - UL Listed HFD
Part Number: FJF2BM14
Quick Summary
Eaton 11-300 series motor control center provides dual feeder motor control for industrial facilities. Engineers often face downtime and wiring complexity when configuring power-distribution schemes, leading to longer commissioning and higher maintenance costs. UL Listed safety certification underpins reliable operation, while the rotary handle design and HFD circuit breakers support fast servicing and dependable protection. The FJF2BM14 balances a compact footprint with robust capability, enabling scalable MCCs in mid-size plants. By aligning with Eaton's standard modules, integrators can streamline procurement and improve spare-part availability, while the 14-inch unit size and dual feed configuration support flexible layouts and straightforward upgrades.
Product Information
Extended Description
FJF2BM14 Eaton: Eaton 11-300 series motor control center, 11-300 Series Dual feeder Motor Control Center 20/125A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 11-300 series motor control center
Catalog Number
FJF2BM14
UPC
786685427218
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
20/125 A
Feature -> Business Impact -> Application: The 11-300 series dual feeder design simplifies upstream power distribution, reducing wiring complexity and shortening installation time in new builds or retrofit projects. Result: faster commissioning, lower field labor costs, and improved system reliability for manufacturing lines and process control. Feature -> Business Impact -> Application: Rotary handle operation enhances operator safety and speeds circuit switching during maintenance, minimizing downtime while preserving protection integrity. Result: safer lockout/tagout procedures and quicker response to alarms in assembly, packaging, and material handling environments. Feature -> Business Impact -> Application: HFD circuit breakers provide selective tripping and robust short-circuit protection, supporting precise coordination with downstream devices. Result: improved uptime and reduced risk of cascading outages in high-demand processes. Feature -> Business Impact -> Application: 14-inch unit size with dual feeder capability delivers a compact, scalable MCC footprint suitable for mid-size installations. Result: easier enclosure integration, simpler future expansion, and compatibility with existing 11-300 module families. Feature -> Business Impact -> Application: UL Listed certification and Eaton warranty framework ensure ongoing compliance and predictable support, reducing risk for procurement and maintenance teams. Result: reliable procurement, standardized spare parts, and clear after-sales coverage for long-term ROI.
Get a Quick Quote for a Eaton FJF2BM14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FJF2BM14?
Enquire Now
FAQs
Installation should follow the Eaton 11-300 series guidelines. The FJF2BM14 uses a dual feeder arrangement with an HFD circuit breaker and rotary handle, designed for a 14-inch unit footprint. Ensure proper mounting within an approved enclosure, verify up to 20/125 A trip settings, and confirm UL Listed compliance before energization. Use compatible bus and accessory kit as per the datasheet for a seamless retrofit or new build.
Primary specs include circuit breaker type HFD, feed type Dual, operation Rotary handle, size 14 in, and trip rating 20/125 A. The unit dimensions are 22 in L (depth), 16 in H, and 25 in W with a weight of 33 lb. UPC 786685427218 and UL Listed certification support compliance and traceability.
Yes. The FJF2BM14 is designed as a dual feeder option within the 11-300 series, enabling parallel feeds to different downstream sections. Confirm enclosure depth and mounting clearances, ensure compatible bus kits, and validate that the downstream protection coordinates with the HFD breaker ratings to achieve proper selectivity and safe operation.
The product carries Eaton’s warranty policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. Routine maintenance includes visual inspections, torque checks on mounting hardware and wiring, and verification of rotary handle operation. Keep the UL Listed labeling intact and document any field service actions for future audits.
Prioritize proper enclosure sealing, ensure adequate ventilation, and maintain clean terminations for the HFD circuit breaker. Use the rotary handle mechanism as intended to engage/disengage power safely, and verify dual feeder routing to prevent overloads. Regularly consult the Eaton specification sheet for model-specific installation notes and torque values to preserve protection integrity.