Eaton FJF2CJ14 Motor Control Center - 25/80A HFD, UL Listed
Part Number: FJF2CJ14
Quick Summary
The Eaton 11-300 series motor control center provides compact, dual-feeder motor control for industrial facilities' motor loads. Designed to reduce wiring complexity and service downtime, it helps engineers meet tight installation schedules without compromising safety. UL Listed certification supports safety compliance for electrical assemblies, and the Eaton 11-300 series is optimized for robust control and protection with a 25/80 A trip rating and HFD circuit breaker. This unit's 14-inch size and rotary handle operation deliver reliable access and simple maintenance, while the dual feeder arrangement increases system scalability. For project teams, it translates to faster commissioning, reduced field wiring errors, and predictable lifecycle costs.
Product Information
Extended Description
FJF2CJ14 Eaton: Eaton 11-300 series motor control center, 11-300 Series Dual feeder Motor Control Center 25/80A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 11-300 series motor control center
Catalog Number
FJF2CJ14
UPC
786685427317
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
25/80 A
Dual feeder configuration is a defining feature of the Eaton FJF2CJ14 MCC, enabling independent feeds to two motor circuits from a single cabinet. This reduces panel count and wiring complexity, delivering faster assembly and easier maintenance. In manufacturing lines with multiple conveyors or pumps, it supports modular expansion and streamlined control logic, improving startup reliability while maintaining consistent protection levels. 25/80 A trip rating with an HFD circuit breaker provides precise overload protection for varied motor loads. The business impact is clearer safety margins and reduced nuisance trips, which translates into less downtime and longer motor life. Practically, this pairing suits mixed motor strategies and helps facilities stay within electrical codes for short-circuit and overload protection. Rotary handle operation offers quick manual isolation and clear visual feedback during maintenance or testing. The 14-inch unit size is space-efficient, enabling fit within constrained electrical rooms and existing switchgear footprints. This combination supports faster commissioning and simpler retrofits in aging facilities. UL Listed certification signals compliance with recognized safety standards for MCC assemblies. This helps procurement teams meet corporate and regulatory expectations without custom engineering. It also aligns with Eaton's warranty and service policies, contributing to predictable lifecycle costs. Dimensions and weight support predictable enclosure design and rack alignment: 22 in depth, 25 in width, 16 in height, about 33 lb. The product is designed for reliable operation in standard industrial environments, and its compatibility with the Eaton 11-300 series ensures interoperability with existing feeders and accessories. Warranty and service terms provide baseline protection: one year from installation or eighteen months from shipment, whichever occurs first. This support reduces lifecycle risk for project teams and helps quiet post-installation surprise costs.
Get a Quick Quote for a Eaton FJF2CJ14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FJF2CJ14?
Enquire Now
FAQs
Plan for a 14-inch unit width within a cabinet footprint of approximately 25 in W x 22 in D x 16 in H, with an estimated 33 lb weight. Ensure access for the rotary handle and dual feeder connections, and verify compatibility with your current 11-300 frame. UL Listed certification supports safety, but confirm local codes and panel standards before integration.
The HFD circuit breaker provides a dual trip rating of 25 A and 80 A, enabling protection for both lighter and heavier motor loads. This supports selective coordination with downstream devices and reduces the risk of nuisance trips. Use appropriate motor protection coordination tables to match applications like conveyors and pumps.
Yes. The dual-feeder design enables two motor circuits to be served from a single MCC, improving control and expandability for lines such as conveyors and pumps. This configuration supports easier future upgrades and modular expansion, while maintaining robust protection with the HFD breakers and rotary isolation for maintenance.
The Eaton FJF2CJ14 is UL Listed, indicating compliance with recognized safety standards for electrical equipment. This certification simplifies procurement and helps meet many corporate safety requirements. Always cross-check with local electrical codes and customer-specific standards, as additional certifications may be required for certain industries.
The dual feeder concept reduces panel count and wiring complexity, cutting installation time and commissioning costs. Rotary handle design simplifies maintenance, while UL Listed certification supports ongoing compliance. The warranty offers a baseline: one year from installation or eighteen months from shipment, whichever occurs first, contributing to predictable lifecycle costs and downtime reduction.