Eaton FJF2CM14 Motor Control Center - UL Listed
Part Number: FJF2CM14
Quick Summary
Eaton FJF2CM14 is a motor control center designed for dual-feeder motor control in industrial facilities. It helps operators overcome wiring complexity, retrofit timelines, and maintenance downtime by consolidating feeders in a single, organized enclosure. UL Listed certification ensures safety and performance, while the HFD circuit breaker and dual feed design support reliable protection across varied loads. This MCC delivers interoperability with Eaton's 11-300 family and supports scalable, maintenance-friendly installation that reduces total cost of ownership. With a 14 inch footprint and 25/125 A trip rating, it aligns with mid-range motor control requirements in manufacturing, packaging, and process industries. End users gain faster commissioning and improved regulatory alignment through documented specifications and a durable, UL Listed solution.
Product Information
Extended Description
FJF2CM14 Eaton: Eaton 11-300 series motor control center, 11-300 Series Dual feeder Motor Control Center 25/125A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 11-300 series motor control center
Catalog Number
FJF2CM14
UPC
786685427348
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
25/125 A
Feature: Dual feeder configuration enables simultaneous protection and control of separate motor circuits. Business Impact: Reduces wiring complexity and allows centralized coordination of motor loads, cutting commissioning time and potential miswiring. Application: Ideal for mid-size manufacturing lines using the Eaton 11-300 series MCC. Long-tail keywords: dual feeder MCC, motor control center, load balancing, centralized protection. Feature: HFD circuit breakers provide precise overcurrent protection and easy coordination with downstream devices. Business Impact: Improves safety margins and minimizes nuisance trips while meeting control reliability targets. Application: Suitable for mixed-duty conveyors and pumps in process facilities. Long-tail keywords: HFD circuit breaker, circuit protection, fault isolation, coordination. Feature: Rotary handle operation supports safe, fast manual switching and maintenance access. Business Impact: Reduces downtime during startup/shutdown and improves operator ergonomics. Application: Critical in shift changes and routine testing in industrial plants. Long-tail keywords: rotary handle MCC, manual operation, maintenance efficiency.Feature: 14 inch unit size and dual feed design offer a compact footprint without sacrificing capacity. Business Impact: Easier panel room planning and faster installation in retrofit projects. Application: Retrofit of legacy MCCs in tight spaces across packaging and material handling lines. Long-tail keywords: 14 inch MCC, compact motor control center, installation efficiency.Feature: UL Listed certification reinforces compliance with safety standards and regulatory requirements. Business Impact: Simplifies audit readiness and supplier qualification for regulated facilities. Application: Data centers, food and beverage processing, and general manufacturing environments. Long-tail keywords: UL Listed MCC, safety certification, regulatory compliance. Feature: 25/125 A trip rating accommodates a range of motor sizes while preserving selective coordination. Business Impact: Optimizes protection without oversizing breakers and controlling total cost of ownership. Application: Medium-duty motor fleets in automation and packaging lines. Long-tail keywords: trip rating 25/125 A, motor protection, selective coordination.
Get a Quick Quote for a Eaton FJF2CM14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FJF2CM14?
Enquire Now
FAQs
To integrate FJF2CM14, verify the enclosure footprint fits the 14 in unit size, connect dual feeders to separately fused circuits, and align the rotary handle operation with the current control scheme. Use the UL Listed MCC documentation for wiring diagrams, ensure proper clearance, and follow Eaton 11-300 series guidelines for sequence and protective coordination.
Key specs to confirm are circuit breaker type HFD, dual feed configuration, 25/125 A trip rating, 14 in unit size, and overall dimensions 22 in L, 16 in H, 25 in W. The product weighs approximately 33 lb and carries a UL Listed certification, supporting safe integration into mid-range industrial loads.
Yes, FJF2CM14 is UL Listed, confirming compliance with safety and performance requirements. It is best suited for dual-feeder motor control needs in manufacturing, packaging, and process industries where compact 14 in MCC footprints, reliable HFD protection, and modular Eaton 11-300 compatibility are advantageous.
Important considerations include ensuring the enclosure fits a 14 in width, providing adequate space for service access, and coordinating with downstream devices for selective protection. Verify mounting alignment with rotary handle operation and verify that wiring conforms to NEC/UL standards. Use the Eaton specification sheet as a reference for exact wiring layouts.
ROI stems from reduced wiring complexity, faster commissioning, and lower maintenance downtime due to modular design and safer, rotary-operated switching. The UL Listed certification supports regulatory compliance, while a compact 14 in footprint minimizes space costs. Long-term cost savings come from predictable lifecycle performance and easier spare parts compatibility within the Eaton 11-300 ecosystem.