Eaton FJF2FN14 Motor Control Center UL Listed

Part Number: FJF2FN14
Manufacturer
Eaton
Part number
FJF2FN14

Quick Summary

Eaton 11-300 series motor control center streamlines motor protection and control for industrial facilities. Engineers often wrestle with coordinating dual feeders and meeting fast-trip requirements across demanding loads. UL Listed certification ensures electrical safety compliance, while the 50/150 A trip rating supports scalable protection. This MCC's dual feeder design and rotary handle simplify wiring and serviceability, while its compact 14-inch footprint reduces panel space and installation costs. Designed for Eaton ecosystems and compatible with 11-300 modules, it supports efficient maintenance planning and scalable upgrade paths. With UL Listed safety and compact dimensions, installation is straightforward in new builds or retrofits.

Product Information

Extended Description

FJF2FN14 Eaton: Eaton 11-300 series motor control center, 11-300 Series Dual feeder Motor Control Center 50/150A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 11-300 series motor control center
Catalog Number
FJF2FN14
UPC
786685427744
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
50/150 A
Dual feeder architecture paired with an HFD circuit breaker delivers two independent power paths within a single MCC, enabling targeted protection and easier fault isolation. The business impact is greater line uptime, simplified maintenance planning, and minimized cross-feed interference across motors and loads. This approach suits facilities with simultaneous pumps, fans, or conveyors, where reliable separation of circuits reduces system-wide risk. The 50/150 A trip rating provides scalable protection for a range of motor sizes and startup currents, reducing nuisance trips while maintaining safety. In production lines with diverse loads, engineers can tailor protection to each circuit and maintain consistent performance metrics. This capability also supports regulatory reporting and energy management initiatives by aligning trip settings with actual duty cycles. Rotatory handle operation enhances control reliability during commissioning, routine checks, and emergency shutdowns. The design reduces keystrokes and misoperation risks in high-traffic switchgear rooms while delivering tactile feedback for operators. For maintenance crews, this translates to shorter downtime, faster re-configuration, and a smoother transition between manual and automatic control modes across multiple MCC sections. The 14-inch unit width preserves valuable panel space while still accommodating essential protective devices and interlocks. A compact footprint lowers installation costs, simplifies routing, and improves accessibility in constrained electrical rooms or retrofits. The unit's dimensions also support modular expansion within the Eaton 11-300 ecosystem, enabling phased upgrades as plant demands grow. UL Listed certification underpins electrical safety compliance for industrial environments, reducing validation time for audits and customer inspections. In conjunction with Eaton's warranty policy, customers gain confidence in long-term serviceability and parts availability. This assurance is especially important for critical processes where downtime penalties are significant and maintenance planning must be predictable. Designed for the Eaton 11-300 family, the FJF2FN14 ensures compatibility with existing components and future upgrades.

Get a Quick Quote for a Eaton FJF2FN14

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton FJF2FN14? Enquire Now

FAQs

FJF2FN14 requires a 14-inch-wide chassis with 22" depth and 25" width clearance in the panel area. Ensure a compatible mounting footprint for the rotary handle MCC style and dual feeder layout. Verify you have UL Listed compliance and access to standard Eaton MCC fittings. Plan wiring routes to minimize bend radius and maintain safe access for service.
The FJF2FN14 uses a dual feeder configuration with an HFD circuit breaker and a 50/150 A trip rating. This combination provides scalable protection across larger motor loads while meeting coordination requirements for dual-motor drives. Use the 50/150 A settings to match your downstream protection scheme and minimize nuisance disconnections during startup.
Yes. The dual feeder design is intended for plants with multiple motor trains, such as conveyors, pumps, and fans. It offers independent protection paths, reduces cross-feed interference, and simplifies maintenance planning. The rugged HFD breaker and rotary handle construction support frequent operation while preserving quick access to individual circuits during commissioning or fault isolation.
UL Listed certification covers safety performance for typical industrial environments and supports streamlined procurement. This designation helps with audits and customer approvals. For broader regulatory compliance in your region, verify additional requirements such as CE marking or SIL alignment as applicable. Having UL Listed status reduces risk during supplier qualification and installation.
Warranty coverage is defined by Eaton's policy, typically one year from installation or eighteen months from shipment, whichever occurs first. Routine maintenance recommendations include periodic front-panel inspection, contact torque verification, and inspection of interlocks and wiring for signs of wear. Availability of spare parts and service support helps minimize downtime and extend equipment life.