Eaton FNF2AC14 Motor Control Center - UL Listed

Part Number: FNF2AC14
Manufacturer
Eaton
Part number
FNF2AC14

Quick Summary

The Eaton FNF2AC14 Motor Control Center is a compact, dual-feeder MCC designed to protect and control motor loads in industrial facilities. For engineers facing tight spaces and complex wiring, the 14-inch unit footprint and rotary handle streamline installation and maintenance. This MCC carries UL Listed safety certification, ensuring compliance with essential electrical standards in demanding environments, while the dual feed design supports scalable power distribution with minimal cabinet depth. The 15/25 A trip rating aligns with common motor sizes, helping prevent nuisance trips without sacrificing protection. By standardizing on this Eaton 9800 series solution, teams can improve installation consistency, reduce commissioning time, and lower lifecycle costs across multiple production lines.

Product Information

Extended Description

FNF2AC14 Eaton: Eaton 9800 series motor control center, 9800 Series Dual feeder Motor Control Center 15/25A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 9800 series motor control center
Catalog Number
FNF2AC14
UPC
786685434964
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
15/25 A
Dual feeder architecture in the FNF2AC14 enables independent power distribution to two motor banks from a single MCC enclosure, reducing wiring complexity while maintaining clear protection boundaries. The HFD circuit breaker provides precise overcurrent protection for each feed, limiting arc-flash risk and enabling fast fault isolation in demanding environments. With a 15/25 A trip rating, the unit suits small to mid-size motor loads and supports scalable automation on mixed-line conveyors and packaging equipment. Rotary handle operation simplifies commissioning and daily maintenance by enabling quick, tool-free cabinet entry and intuitive control of disconnection. This design minimizes training time for maintenance crews and reduces the risk of operator errors during startup. The mechanism works with standard Eaton 9800 accessories, easing field retrofits and ensuring consistent performance across upgrades. At 14 inches in unit size, this MCC delivers space savings in crowded control rooms while still accommodating a dual feeder arrangement. The compact footprint supports closer equipment spacing and front-access wiring, accelerating installation and reducing on-site labor. For retrofit projects, the smaller envelope helps meet existing footprint constraints without sacrificing protection. UL Listed safety certification confirms adherence to recognized electrical standards, supporting compliance in manufacturing, process industries, and automotive applications. This assurance simplifies supplier qualification and audit readiness for sites with strict procurement policies. End users benefit from documented safety performance while integrators can market the Eaton 9800 series as a reliable, standards-aligned MCC. Compatibility with the Eaton 9800 series family means consistent control logic, common spare parts, and a unified maintenance approach across lines. The dual feeder design integrates with typical motor starters and overload protection, enabling scalable expansion without reworking control wiring. Field technicians appreciate standardized connections and predictable fault behavior. From a maintenance and total cost perspective, the FNF2AC14 reduces downtime through modular components and straightforward access, while warranty coverage aligns with industry expectations for critical safety assets. Operators can expect lower lifecycle costs as field upgrades stay aligned with Eaton's MCC roadmap.

Get a Quick Quote for a Eaton FNF2AC14

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton FNF2AC14? Enquire Now

FAQs

The FNF2AC14 shines in manufacturing lines, packaging, processing, and material handling where dual feeders are needed and space is at a premium. Its 14-inch unit size fits compact panels, while the rotary handle and HFD protection streamline setup, commissioning, and routine maintenance without sacrificing motor protection.
The 15/25 A trip rating matches typical small to mid-size motors, preventing nuisance trips on startup and under overload while preserving fast fault isolation. Combined with the HFD breaker, this delivers reliable protection with minimal downtime, helping maintain line throughput and reduce energy waste from unnecessary trips.
Yes. The FNF2AC14 is designed as part of the Eaton 9800 series, featuring a dual feeder arrangement and rotary handle architecture that aligns with existing MCC frameworks. This compatibility enables straightforward upgrades, spare parts standardization, and consistent control logic across many lines.
This unit is UL Listed, confirming compliance with recognized electrical safety standards for MCCs. While other certifications may vary by region, UL Listed status provides a strong baseline for regulatory acceptance in North American installations and supports safer fault handling and routine maintenance.
A single FNF2AC14 installation can reduce wiring complexity and installation time, lowering labor costs during commissioning. Durable construction and UL safety certification help minimize downtime, while compatibility with Eaton spares and upgrades reduces lifecycle expenses. Over multiple lines, the payoff includes standardized maintenance and faster fault recovery.