Eaton FNF2CM14 Motor Control Center - UL Listed
Part Number: FNF2CM14
Quick Summary
Eaton 9800 series motor control center provides centralized protection and control for dual-fed motor systems in industrial environments. Engineers often grapple with wiring complexity, downtime risk, and space constraints when expanding motor control architectures. UL Listed safety certification helps ensure compliance with electrical safety standards and reduces audit friction. Designed for dual feeders and 14-inch layouts, this solution enables faster deployment, easier maintenance, and predictable lifecycle costs for industrial facilities. This combination of compact footprint, robust protection, and simple operation supports reliable uptime across manufacturing, packaging, and process-control environments.
Product Information
Extended Description
FNF2CM14 Eaton: Eaton 9800 series motor control center, 9800 Series Dual feeder Motor Control Center 25/125A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 14-inch unit size
Product Name
Eaton 9800 series motor control center
Catalog Number
FNF2CM14
UPC
786685435312
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
14 in
Trip rating
25/125 A
Eaton Specification Sheet - FNF2CM14
Selling Policy 25-000 - Distribution and Control Products and Services
The 14-inch unit size delivers a compact footprint that frees valuable floor and cabinet space, enabling easier integration into crowded control rooms and machine enclosures. Business impact: reduced installation time and lower enclosure costs, with clear space for wiring runs and future expansions in existing lines. Application: mid-size manufacturing lines where space is at a premium and reliability is critical. The dual feeder design provides built-in redundancy, allowing one feeder to be serviced without interrupting the other, which translates to less downtime during maintenance and faster changeovers in high-demand processes. This capability is ideal for packaging lines and continuous-process equipment where uptime is non-negotiable. The rotary handle operation offers quick, intuitive control and safer manual intervention, reducing training time for new technicians and minimizing startup delays during commissioning. In practice, technicians gain faster access to circuits and simplified fault isolation, improving overall maintenance efficiency on the shop floor. The HFD circuit breaker with a 25/125 A trip rating delivers selective protection for both feeders, helping coordinate protection with motors of varying sizes while preventing nuisance trips. This translates to fewer false trips and more controlled outages during faults. Compatibility with standard Eaton accessories and modular MCC components simplifies retrofits and future upgrades, ensuring seamless integration with existing infrastructure. From a reliability standpoint, the 14-inch unit fits typical rack-and-panel configurations and aligns with Eaton’s warranty framework, providing predictable service expectations and downstream cost savings. Overall, the FNF2CM14 supports easier procurement, faster installation, and proven performance for demanding industrial environments such as assembly lines, material handling, and process control.
Get a Quick Quote for a Eaton FNF2CM14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FNF2CM14?
Enquire Now
FAQs
To install the FNF2CM14 MCC, plan for a compact 14-inch footprint and verify cabinet clearance for the 22 in depth, 25 in width, and 16 in height. Mount the MCC securely, wire the dual feeders to their respective bus bars, and configure the rotary handle operation for manual control. Ensure compliance with UL Listed guidelines and verify wiring terminals meet the 25/125 A trip rating coordination. After mounting, perform insulation resistance checks and a controlled current bypass test to confirm dual-feed redundancy before commissioning heavy loads.
The 25/125 A trip rating indicates dual-stage protection where the lower 25 A limit provides protection for smaller, sensitive circuits and the higher 125 A limit accommodates larger motors or motor starters within the same MCC. This arrangement helps coordinate protection with varying motor sizes, reduces nuisance trips for normal startups, and improves selective coordination across feeders. In practice, it supports safer operation and better uptime by aligning protection with motor inrush characteristics and wiring demand.
Yes. The FNF2CM14 is designed for dual-feeder configurations, compact 14-inch form factor, and rotary handle operation, which suits manufacturing line start-ups and packaging lines where space is limited and reliability is essential. Its HFD circuit breaker protection and UL Listed certification provide industry-acceptable safety and performance, while the modular design supports quick deployment and scalable expansion as production requirements grow.
The FNF2CM14 is UL Listed, indicating it meets designated safety requirements for electrical assemblies and components used in industrial control equipment. UL Listing supports compliance with recognized electrical safety standards, aiding in regulator audits and system safety validations. For specific standard citations, refer to Eaton’s documentation and the UL listing data sheet accompanying this product.
The product carries Eaton’s standard warranty policy, which defines coverage terms from installation or shipment, whichever occurs first, and supports long-term maintenance planning. In practice, this translates to predictable repair/replacement costs, easier budgeting for lifecycle management, and reduced risk of unexpected downtime. For ROI, consider the dual feeder capability, compact footprint, and easy retrofit path with compatible Eaton accessories, all contributing to faster deployment, minimized maintenance time, and extended equipment life.