Eaton FNF2DN18 Motor Control Center - UL Listed, 30/150 A Dual Feeder
Part Number: FNF2DN18
Quick Summary
The Eaton FNF2DN18 motor control center enables centralized motor control for dual-feed applications in industrial facilities. This MCC design minimizes panel footprint while enhancing safety and coordination for motor-driven equipment. A common challenge is balancing space constraints with safety and regulatory compliance; the FNF2DN18 addresses this with an 18-inch-wide dual feeder layout and a rotary handle for fast, lockable disconnects. The unit carries UL Listed certification, supporting compliant integration into standard electrical installations. Leveraging Eaton’s 9800 series heritage, it delivers robust performance, compatibility with existing Eaton components, and predictable lifecycle costs for procurement teams and engineers alike.
Product Information
Extended Description
FNF2DN18 Eaton: Eaton 9800 series motor control center, 9800 Series Dual feeder Motor Control Center 30/150A trip rating, HFD circuit breaker, Dual feeder, Rotary handle mechanism, 18-inch unit size
Product Name
Eaton 9800 series motor control center
Catalog Number
FNF2DN18
UPC
786685435459
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Rotary handle
Size
18 in
Trip rating
30/150 A
Feature: Dual feeder configuration and 30/150 A trip rating enable load sharing and precise protection. Business impact: Improved motor start-up sequencing and robust protection reduce unscheduled downtime and avoid equipment damage. Application: Suitable for multi-motor lines in manufacturing or processing plants where space is at a premium and coordinated protection is required. Feature: HFD circuit breaker integration with rotary handle operation. Business impact: Faster, safer disconnection during maintenance and fault isolation, boosting maintenance efficiency and personnel safety. Application: Live-tac and emergency procedures in high-cycle environments. Feature: 18-inch unit width and overall compact footprint. Business impact: Space savings in control rooms and switchgear enclosures, enabling tighter installations and easier retrofits. Application: Retrofit projects in equipment rooms with limited footprint. Feature: 18-inch size, dual feed, and Eaton 9800 series compatibility. Business impact: Streamlined procurement and reduced engineering effort due to plug-and-play compatibility with existing Eaton MCC components. Application: New installations and expansion of existing lines across industrial facilities. Feature: UL Listed certification and standard warranty. Business impact: Compliance assurance and reduced risk through recognized safety certification; standard one-year warranty supports total cost of ownership. Application: Regulated industries and facilities prioritizing safety and supplier reliability.
Get a Quick Quote for a Eaton FNF2DN18
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FNF2DN18?
Enquire Now
FAQs
The FNF2DN18 uses a dual feeder configuration designed for parallel motor circuits. Its rotary handle operation provides quick, secure disconnects, reducing maintenance time and enhancing safety during wiring, testing, and replacement activities. The unit is compatible with standard Eaton MCC mounting practices and fits within typical 18-inch-wide enclosures, simplifying upgrades and retrofits.
Key specifications include a 30/150 A trip rating, HFD circuit breaker type, dual feed capability, rotary handle operation, and an 18-inch unit size. The MCC is UL Listed, ensuring compliance with common safety standards, and the unit weight is approximately 33 lb with a footprint of 22 in depth, 16 in height, and 25 in width as per the datasheet.
Yes. The FNF2DN18 is UL Listed, supporting compliance in regulated environments and easing integration into UL-based electrical installations. Its compact 18-inch form factor and dual feeder design make it ideal for industrial facilities seeking reliable protection for multiple motors while meeting safety and certification requirements.
Applications include mid-sized manufacturing lines, packaging and processing facilities, and process industries requiring centralized motor control with space efficiency. The dual feeder arrangement, 30/150 A trip range, and compatibility with Eaton 9800 series components provide scalable protection and simplified expansion for growing motor control needs.
Eaton provides a one-year warranty from installation or 18 months from shipment, whichever occurs first. Support includes access to Eaton’s documentation, specification sheets, and product team guidance to ensure proper installation, maintenance planning, and lifecycle cost management.