Eaton FRK1X24 Motor Control Center UL Listed HKD 400A
Part Number: FRK1X24
Quick Summary
FRK1X24 Eaton motor control center provides compact 24 in feeder control for industrial motor panels. Engineers often struggle with space constraints, tight integration, and ensuring correct breaker coordination in MCCs. UL Listed certification ensures safety compliance, while HKD circuit breaker type supports reliable protection in a K-frame feeder configuration. The 400 A trip rating matches typical medium‑duty motor loads, and the 24-inch unit size fits standard electrical rooms without sacrificing accessibility thanks to the lever/slider handle design. Designed for industrial automation environments, this MCC aligns with Eaton’s F10 family, enabling straightforward installation, serviceability, and scalable protection across multiple motors and feeders.
Product Information
Extended Description
FRK1X24 Eaton: Eaton F10 series motor control center, F10 Series K-Frame feeder Motor Control Center 400A trip rating, HKD circuit breaker, K Frame feeder, Lever/Slider handle mechanism, 24-inch unit size
Product Name
Eaton F10 series motor control center
Catalog Number
FRK1X24
UPC
786685428956
Product Length/Depth
23 in
Product Height
14 in
Product Width
36 in
Product Weight
43 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HKD
Feed type
K-frame feeder
Operation
Lever/slider handle
Size
24 in
Trip rating
400 A
The 24‑inch wide footprint of FRK1X24 is a space‑saving choice for dense electrical rooms and retrofit projects. With a 23‑inch depth and a 14‑inch height profile, it fits standard MCC racks while leaving room for cabling and labeling. The unit consolidates feeder and motor control components, reducing interconnecting harnesses and simplifying field wiring. This compact form factor accelerates installation in new facilities and minimizes mechanical conflicts during plant expansions, all while maintaining full access for maintenance. HKD circuit breaker type provides robust overload protection aligned with K-frame feeders. The HKD type is designed to handle high‑current motor protection with predictable trip characteristics, reducing nuisance trips and improving uptime. The UL Listed certification supports compliance with common industry safety standards and regulatory expectations, easing audits and downstream approvals. Lever/slider handle operation enhances safety and serviceability. The design allows quick isolation of feeders without reaching into energized compartments, which reduces exposure risk during start‑ups and routine testing. Coupled with Eaton’s standardization across the F10 family, technicians benefit from consistent field procedures and spare parts availability across sites. With a 400 A trip rating, FRK1X24 supports common medium‑duty motor loads while protecting equipment from short‑circuit events. The combination of robust protection and 24‑inch width aids in achieving precise load shedding, improved motor starting performance, and better coordination with downstream protection devices. This MCC is well suited for packaging lines, conveyors, and machine control panels where reliability matters most. Designed for compatibility within Eaton’s F10 motor control center ecosystem, FRK1X24 offers scalable protection, modular expansion, and straightforward installation in both new builds and retrofits. Its documented dimensions enable efficient procurement, rack planning, and cable management in controlled environments. Operators also gain long‑term value from predictable performance, reduced maintenance costs, and a clear upgrade path as plant demand grows.
Get a Quick Quote for a Eaton FRK1X24
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FRK1X24?
Enquire Now
FAQs
FRK1X24 is a 24‑inch wide MCC module designed to fit standard K-frame feeder panels. Plan for 23‑inch depth and 14‑inch height to maintain clear cabling pathways and access to the lever/slider handle. Verify HKD breaker compatibility, follow UL Listed wiring practices, and provide adequate space for labeling and future expansion during initial installation.
FRK1X24 uses an HKD circuit breaker type with a 400 A trip rating to protect medium‑duty motors. This configuration supports proper coordination with upstream devices and minimizes nuisance trips. Ensure feeder conductors and bus sizes are sized per NEC guidelines, and rely on UL Listed documentation for field verification and maintenance scheduling.
Yes, its 24‑inch width and 400 A protection make it well suited for mid‑size lines such as packaging, conveyors, and machine control panels. The K‑frame feeder and lever/slider operating mechanism simplify integration with existing Eaton F10 MCCs, enabling scalable protection across multiple motors. Consider space planning, cooling, and cable management for ongoing reliability.
FRK1X24 carries UL Listed certification, confirming compliance with essential electrical safety standards. The lever/slider mechanism and HKD breaker compatibility meet industry expectations for safety and performance in industrial automation. While CE or IP ratings are not specified in the data, this unit is positioned for safe, compliant operation in controlled environments.
Maintenance benefits include safer isolation via the lever/slider handle and faster service procedures thanks to the modular K-frame design. The 24‑inch MCC aligns with common room footprints, reducing wiring complexity and downtime during changeovers. With UL Listed safety, a 400 A protection scheme, and compatibility within the Eaton F10 family, it supports predictable performance and lower total cost of ownership.