Eaton FTF2LC12 Motor Control Center - UL Listed
Part Number: FTF2LC12
Quick Summary
Eaton FTF2LC12 motor control center is a dual-feeder MCC designed for compact power distribution in manufacturing and processing plants. Space constraints and downtime are common pain points; this 12-inch unit with a slider handle enables quicker access and safer maintenance. UL Listed certification provides essential safety compliance for industrial environments, while the dual feeder configuration supports selective protection of motor loads. Engineers and buyers gain predictable performance, scalable installation, and a favorable total cost of ownership through robust Eaton design and documented warranty. This combination helps ensure faster project delivery by reducing field wiring complexity and enabling straightforward commissioning. With Eaton's service support and readily available replacement parts, maintenance planning becomes more predictable.
Product Information
Extended Description
FTF2LC12 Eaton: Eaton type W motor control center, Type W Dual feeder Motor Control Center 100/25A trip rating, HFD circuit breaker, Dual feeder, Slider handle mechanism, 12-inch unit size
Product Name
Eaton type W motor control center
Catalog Number
FTF2LC12
UPC
786685434445
Product Length/Depth
22 in
Product Height
16 in
Product Width
25 in
Product Weight
33 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Circuit breaker type
HFD
Feed type
Dual
Operation
Slider handle
Size
12 in
Trip rating
100/25 A
Dual feeder configuration with an HFD circuit breaker enables independent protection of two motor circuits. Business impact: reduced wiring complexity, improved fault isolation, and enhanced selective coordination, helping maintain critical loads during a fault. Application: ideal for manufacturing lines and processing equipment where two independently protected feeders must share a common bus. This arrangement supports safer, faster troubleshooting and minimizes unplanned downtime. The 12-inch unit size delivers a compact footprint without sacrificing protection or performance. Business impact: space savings facilitate retrofit projects and easier integration into crowded control rooms. Application: space-constrained facilities and retrofits where panel real estate is at a premium. Slider handle operation provides quick access and safer maintenance. Business impact: reduces maintenance time and improves operator safety, especially during routine testing or fault isolation. Application: frequent feeder inspections and routine commissioning in production lines. UL Listed certification ensures compliance with essential safety standards. Business impact: simplifies procurement and regulatory alignment for industrial facilities. Application: procurement-driven installations in manufacturing and process environments requiring UL safety validation. The 100/25 A trip rating delivers reliable overload protection across dual feeders. Business impact: supports safe motor starting and coordinated protection for mixed load profiles. Application: general purpose motors and conveyors in manufacturing plants. Compatibility with Type W MCCs enhances deployment speed. Business impact: minimizes integration risk and accelerates commissioning. Application: retrofit projects or multi-vendor facilities seeking seamless compatibility. With a robust warranty and Eaton’s support network, total cost of ownership is favorable over the product life cycle. Application: long-term maintenance planning and budget-friendly equipment upgrades.
Get a Quick Quote for a Eaton FTF2LC12
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton FTF2LC12?
Enquire Now
FAQs
Installation begins by confirming electrical compatibility with existing Type W MCC infrastructure and ensuring the enclosure footprint matches the 12 inch unit size. Follow Eaton’s wiring diagram to connect the dual feeders to the HFD breakers, verify the slider handle operation, and secure the unit with appropriate mounting hardware. Complete with a safety lockout/tagout and post-install electrical checks.
The 100/25 A trip rating provides selective overload protection for larger motors and lighter loading on the paired feeders. This coordination helps minimize nuisance trips during startup while keeping individual feeders protected during faults. In practical terms, it supports reliable operation of mixed load profiles common in conveyors, pumps, and fans within a single MCC cabinet.
Yes, the 12-inch unit size with a compact 22 in depth by 16 in height by 25 in width footprint is well-suited for tight control rooms. Mounting should align with standard DIN rail or pad mounting practices used in Type W MCCs, using the manufacturer’s recommended hardware. Ensure adequate clearance for the slider handle and wiring access during service.
The FTF2LC12 is UL Listed, providing essential safety certification for industrial electrical equipment. This status supports compliance in most North American industrial facilities and simplifies procurement for projects that require recognized safety marks. Always verify local regulatory requirements and ensure alignment with site-specific commissioning standards.
Benefits include reduced maintenance time due to the slider handle design and quick-access features, improved fault isolation limiting downtime, and scalable expansion without panel rework. In high-use lines, these factors translate to lower labor costs, faster mean time between failures, and a shorter project ramp-up, delivering tangible lifecycle cost savings.