Eaton GHG8714221R0001 LED Emergency Light - IP66
Part Number: GHG8714221R0001
Quick Summary
The Eaton GHG8714221R0001 LED emergency light fixture provides reliable illumination in hazardous locations. Maintenance and compliance can be challenging in confined spaces and harsh environments. It carries IECEx/ATEX certification for Zones 1, 2, 21 and 22 and an IP66 rating. For industrial users, this hazardous area lighting solution supports code-compliant installations while reducing downtime and energy costs. Its compact dimensions—164.5 mm long, 189 mm high, and 128 mm wide—coupled with 200 lumens at 230 VAC and a 37 mA draw, help operators plan safer, cost-efficient retrofits.
Product Information
Extended Description
GHG8714221R0001 Eaton: Eaton Crouse-Hinds series CEAG dKLK 23 LED emergency light fixture, 37 mA, 50-60 Hz, Green, 200 lumens, Glass-fibre reinforced polyester, Polycarbonate cover, 1 x eXlink coupler 2-pole + PE for cable diameter 7.5-11 mm, 230 Vac
Product Name
Eaton's Crouse-Hinds series CEAG dKLK 23 LED emergency light fixture
Catalog Number
GHG8714221R0001
EAN
4250217403415
Product Length/Depth
164.5 mm
Product Height
189 mm
Product Width
128 mm
Product Weight
1.7 kg
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 1 Zone 2 Zone 22 Zone 21
Ingress protection (IP) ratings
IP66
Lamp type
LED
Voltage rating
230 Vac
Frequency rating
50-60 Hz
Amperage Rating
37 mA
Lumens
200
Material
Glass-fibre reinforced polyester
Letter color
Green
Special features
Polycarbonate cover
Type
1 x eXlink coupler 2-pole + PE for cable diameter 7.5-11 mm
Crouse-Hinds series CEAG dKLK LED Emergency Light Fixtures catalog page
EC Type Examination Certificate - dKLK LED
EC Type Examination Certificate - dKLK LED
EC Type Examination Certificate - dKLK LED
Operating Instructions - dKLK LED Emergency Light Fixtures
dKLK LED Emergency Light Fixtures photometric files
LED illumination at a low current draw minimizes electricity use while delivering 200 lumens, reducing energy costs and extending battery-backup reliability—vital for safe egress in hazardous locations. This efficiency translates to fewer maintenance cycles and lower total cost of ownership in oil, gas, chemical, and other high-risk industries. IECEx/ATEX certification for Zones 1, 2, 21 and 22 together with IP66 ingress protection ensures compliance with international hazardous-location standards, enabling straightforward procurement and risk reduction on global projects. Engineers can rely on consistent performance across extreme conditions, with minimal risk of ingress and corrosion compromising survivor illumination during outages. The durable housing (glass-fibre reinforced polyester) and polycarbonate cover withstand vibration, moisture, and chemical exposure, supporting long service life in demanding plants. A built-in 1 x eXlink coupler 2-pole + PE for 7.5–11 mm cables simplifies wiring, speeding installation and reducing field wiring errors. The unit fits neatly within CEAG dKLK LED lighting schemes, making retrofits and panel upgrades efficient and predictable.
Get a Quick Quote for a Eaton GHG8714221R0001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton GHG8714221R0001?
Enquire Now
FAQs
Begin by verifying Zone and IP66 ratings for the installation site and ensure power is isolated. Mount the unit using standard CEAG mounting provisions, connect mains to 230 VAC 50–60 Hz, and use the built‑in 1 x eXlink coupler for 7.5–11 mm cables. Ensure the enclosure remains sealed to protect against dust and moisture and verify that the wiring meets local wiring regulations and hazardous-area standards.
The fixture carries IECEx/ATEX certification for Zones 1, 2 and 21, 22 hazardous locations, coupled with an IP66 ingress protection rating. These certifications confirm suitability for explosive atmospheres and exposure to dust and water. Use of this product helps meet global regulatory requirements and simplifies cross-border project documentation and approvals.
The GHG8714221R0001 delivers 200 lumens with a current draw of 37 mA at 230 VAC and 50–60 Hz. This combination provides bright, reliable emergency illumination while minimizing energy consumption. The low current draw also reduces thermal load and extends backup battery life in outage scenarios, supporting continuous operation in harsh environments.
Yes. The unit uses a 1 x eXlink coupler 2-pole + PE and is designed to integrate with CEAG dKLK LED emergency lighting schemes. Its polycarbonate cover and glass‑fibre reinforced polyester body align with CEAG aesthetics and mounting footprints, ensuring straightforward retrofits and dependable performance within established plant layouts.
The LED design reduces lamp replacements and energy usage, lowering ongoing maintenance costs. Its rugged housing and IP66/IECEx‑ATEX certifications minimize downtime and regulatory risk in hazardous zones, delivering predictable life-cycle costs. In practice, facilities see improved reliability, faster commissioning, and a safer work environment with lower total cost of ownership.