Eaton HCLR15 Edison fuse - UL Listed, 200 kAIC
Part Number: HCLR15
Quick Summary
HCLR fuse protects electrical circuits in industrial panels with reliable short-circuit protection. Mismatched replacements often lead to nuisance trips or slow repairs, increasing downtime and maintenance costs for plant owners and integrators. This Eaton Edison device carries UL Listed and CSA Certified marks, CE compliance, and RoHS adherence, reinforcing safety and regulatory readiness. As part of the Edison Class CC family, the HCLR15 combines compact size with robust performance, helping you optimize spare parts inventory and panel design. By choosing a standard, non-indicating fuse with a 600 V rating, you gain predictable protection and easier field servicing, reducing total cost of ownership across enrolled control systems. This aligns with broader procurement goals of reliability, regulatory compliance, and cost containment.
Product Information
Extended Description
HCLR15 Eaton: Eaton Edison HCLR fuse, 15 A, Class CC, Non-indicating, 200 kAIC, Standard, 10, 600 V
Product Name
Eaton Edison HCLR fuse
Catalog Number
HCLR15
UPC
782634420705
Product Length/Depth
1 in
Product Height
0.406 in
Product Width
0.406 in
Product Weight
0.001 lb
Warranty
No warranty
Compliances
RoHS Compliant CE Marked
Certifications
UL Listed CSA Certified
Amperage Rating
15 A
Interrupt rating
200 kAIC
Voltage rating
600 V
Packaging type
Standard
Class
Class CC
Fuse indicator
Non-indicating
Quantity
10
Special features
Rejection style
Feature → Business Impact → Application: Amperage Rating and Interrupt Rating. The HCLR15 delivers a 15 A rating with a 200 kAIC interrupt capability, ensuring fast, clean fault isolation in high-energy panel environments. This translates to reduced fault duration and minimized risk of collateral damage in machine control circuits and DC bus protection scenarios. Feature → Business Impact → Application: Class CC, Non-indicating, Rejection style. Rejection style helps ensure only correct fuses are installed in each holder, reducing human error and replacement costs. This suits multi-fuse panels in manufacturing lines and distribution centers where quick, accurate maintenance is critical. Feature → Business Impact → Application: Voltage rating and packaging. With a 600 V rating and standard packaging, installation is straightforward in typical control panels; the compact 1 in length and 0.406 in dimensions fit densely populated enclosures, cutting panel footprint and simplifying stocking. Feature → Business Impact → Application: Certifications and compliance. UL Listed, CSA Certified, RoHS and CE Marked protect your compliance posture and simplify audits for global operations. This is especially valuable for OEMs and integrators delivering systems to markets with strict safety and environmental requirements. Feature → Business Impact → Application: Compatibility and maintenance. The 10-unit quantity per pack aligns with common stocking strategies; compatibility with Eaton Edison series fuses reduces spare parts diversity, lowering procurement complexity and downtime during replacements. Engineers appreciate the predictability of standard Edison catalog items.
Get a Quick Quote for a Eaton HCLR15
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton HCLR15?
Enquire Now
FAQs
The HCLR15 is designed with a compact footprint: 1 inch length, 0.406 inch width, and 0.406 inch height. It is a non-indicating Class CC fuse, compatible with standard Edison fuse holders and typical control panel layouts. Its standard packaging (ten fuses per pack) simplifies stocking and replacement in busy environments.
The HCLR15 is UL Listed and CSA Certified, with RoHS compliance and CE Marking. These certifications support regulatory compliance across North America and Europe, reduce audit friction, and enable safer integration in mixed supply chains and multinational projects.
Ideal for industrial control panels, motor control circuits, and power distribution blocks within 600 V systems, the HCLR15 delivers precise overcurrent protection with a 15 A rating and 200 kAIC interrupt capability. Its compact form factor, rejection feature, and standard Edison catalog compatibility optimize installation and maintenance workflows.
The rejection style prevents incorrect fuse installation by design, reducing human error during maintenance or part replacement. This is especially valuable in panels housing multiple Class CC fuses, where incorrect substitutions can lead to nuisance trips or equipment damage, ultimately lowering downtime and spare-parts costs.
Using a standardized Edison fuse like the HCLR15 reduces stocking variety and simplifies procurement, lowering inventory carrying costs. The high interrupt rating minimizes fault duration, contributing to less downtime, fewer field failures, and more predictable maintenance planning across manufacturing lines and process environments.