Eaton HCLR3 Fuse - Class CC, 200 kAIC, UL Listed

Part Number: HCLR3
Manufacturer
Eaton
Part number
HCLR3

Quick Summary

The Eaton Edison HCLR3 fuse provides fast protection for low-voltage control circuits in industrial panels. When panel space is tight, selecting a compact, reliable fuse reduces downtime and simplifies maintenance. It carries CSA Certified and UL Listed markings and is RoHS compliant and CE marked, ensuring regulatory and safety compliance. Built for electrical protection & circuit control, this 3 A fuse delivers predictable performance, helping equipment vendors meet uptime and compliance goals. The combination of reliability, regulatory compliance, and a compact form factor adds measurable business value for panel builders and machinery integrators.

Product Information

Extended Description

HCLR3 Eaton: Eaton Edison HCLR fuse, 3 A, Class CC, Non-indicating, 200 kAIC, Standard, 10, 600 V
Product Name
Eaton Edison HCLR fuse
Catalog Number
HCLR3
UPC
782634420620
Product Length/Depth
1 in
Product Height
0.406 in
Product Width
0.406 in
Product Weight
0.001 lb
Warranty
No warranty
Compliances
RoHS Compliant CE Marked
Certifications
CSA Certified UL Listed
Amperage Rating
3 A
Interrupt rating
200 kAIC
Voltage rating
600 V
Packaging type
Standard
Class
Class CC
Fuse indicator
Non-indicating
Quantity
10
Special features
Rejection style
Designed around Eaton Edison fusion technology, the HCLR3 uses a Class CC, non-indicating fuse design that packs essential protection into a compact footprint. This form factor preserves precious panel space, simplifies routing, and reduces enclosure depth without compromising safety margins or fault-clearing performance. The 3 A amperage rating, 600 V voltage rating, and standard 10-unit packaging support straightforward selection, stocking, and interchangeability in automation projects. With an interrupt rating of 200 kAIC, the HCLR3 safely interrupts high fault currents, protecting downstream devices and cutting the risk of collateral damage during short circuits. This robustness translates into higher equipment uptime and more predictable maintenance cycles in manufacturing environments where reliability is critical. The non-indicating design, coupled with a rejection style feature, minimizes nuisance trips in dense cabinets while enabling external indication or supervisory monitoring as needed. UL Listed and CSA Certified, alongside RoHS compliance and CE marking, the HCLR3 meets major global safety and environmental standards, reducing procurement risk for multinational projects. These certifications simplify cross-border sourcing, streamline supplier qualification, and support regulatory acceptance across automotive, packaging, and process industries. Additionally, its compatibility with standard Edison fuse blocks and full Edison line reputation ensures consistent spare-part install and long-term maintenance planning. From a practical standpoint, the standard packaging and ten-unit quantity align with common stocking strategies, accelerating kit builds and field replacements. The rejection-style design helps prevent incorrect fusing during maintenance in crowded panels, while the small form factor minimizes cabinet modification needs. In real-world deployments, engineers benefit from faster changeouts, fewer unplanned trips, and lower lifecycle costs when deploying the HCLR3 for 600 V control circuits.

Get a Quick Quote for a Eaton HCLR3

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton HCLR3? Enquire Now

FAQs

Install the HCLR3 into a compatible Class CC fuse holder rated for 600 V. Ensure the amperage rating is matched to 3 A and verify tight, clean contacts to prevent heat buildup and arcing. Because the fuse is non-indicating, plan for external status indication or supervisory monitoring to confirm fuse health during maintenance.
The HCLR3 features a 3 A amperage rating, 600 V voltage rating, and a 200 kAIC interrupt rating. It uses a Class CC, non-indicating design and carries RoHS compliance along with CE marking. UL Listing and CSA Certification ensure broad regulatory acceptance for industrial control applications.
Yes. The HCLR3 is RoHS Compliant and CE Marked, with additional CSA Certified and UL Listed certifications. These attributes support compliance in global supply chains and simplify procurement for multinational projects, from automotive to packaging machinery.
Best suited for low-voltage control circuits in industrial panels, machine controls, and motor control centers. Its compact Class CC form factor, 3 A rating, 600 V capability, and 200 kAIC interrupt rating make it ideal for control cabinets with space constraints and higher fault-current scenarios.
The HCLR3 reduces downtime through high fault-current protection and reliable interruption. Its standard packaging of ten units simplifies stocking and replacements, lowering spare-part costs and warehouse complexity. Combined with regulatory compliance, it minimizes procurement delays and accelerates project timelines while supporting predictable lifecycle costs.