Eaton JGSDC3090FAW PV Guard - Complete DC MCCB, UL 489

Part Number: JGSDC3090FAW
Manufacturer
Eaton
Part number
JGSDC3090FAW

Quick Summary

The Eaton PV Guard JGSDC3090FAW is a complete molded case circuit breaker for PV solar protection and DC power systems. Design teams often struggle with delivering reliable DC protection across varied PV array configurations while staying within space and wiring constraints. It carries UL 489 certification and supports 50/60 Hz operation with 600 Vac and 250 Vdc ratings, ensuring regulatory compliance. As part of the PVGuard family, this unit uses a compact JG frame, integrates without terminals, and pairs with Eaton’s protection ecosystem to reduce downtime, simplify maintenance, and lower lifecycle costs.

Product Information

Extended Description

JGSDC3090FAW Eaton: Eaton Series G DC/PvGard complete molded case circuit breaker, JG-frame, JG, Fixed thermal, adjustable magnetic trip, Three-pole, 90A, 600 Vac, 250 Vdc, 85 kAIC at 240 Vac, 35 kAIC at 480 Vac, 18 kAIC at 600 Vac, No terminals, 50/60 Hz
Product Name
Eaton PV Guard / Solar complete molded case circuit breaker
Catalog Number
JGSDC3090FAW
UPC
786685494418
Product Length/Depth
3.44 in
Product Height
7 in
Product Width
4.13 in
Product Weight
6.5 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL 489
Amperage Rating
90 A
Voltage rating
600 Vac, 250 Vdc
Trip Type
T185
Circuit breaker type
JG
Circuit breaker frame type
Complete breaker
Series
Series G
Terminals
Without terminals
Frame
JG
Frequency rating
50/60 Hz
Interrupt rating
35 kAIC at 480 Vac 85 kAIC at 240 Vac 18 kAIC at 600 Vac
Number of poles
Three-pole
Three-pole construction with the JG frame provides coordinated protection across PV DC circuits, helping prevent cascading faults. The 90 A amperage rating paired with 600 Vac and 250 Vdc voltage ratings gives solid fault handling for modern solar installations. In practice, this means fewer mis-trips during transient conditions, greater protection for inverters and DC conductors, and improved system uptime in commercial and utility-scale PV projects. Because the unit is specified without terminals, installation is streamlined in compact PV enclosures where space and wiring cavities are at a premium. External termination options and compatibility with Eaton’s PVGuard accessories simplify wiring, shorten panel assembly times, and reduce stocking complexity. The result is faster commissioning, lower labor costs, and a cleaner, safer electrical bus in PV combiner boxes and inverter interfaces. The fixed thermal, adjustable magnetic trip (T185) delivers precise, field-adjustable protection that can be tuned to inverter fault currents and PV string configurations. This allows designers to coordinate with upstream devices, minimize nuisance trips, and maintain consistent protection across temperature variations. In practice, it supports reliable DC fault clearance in fluctuating solar irradiance environments and helps protect critical equipment. With industry-leading interrupt ratings—85 kAIC at 240 Vac, 35 kAIC at 480 Vac, and 18 kAIC at 600 Vac—the JGSDC3090FAW can safely interrupt high fault currents common in PV and utility-interactive systems. This margin reduces arc energy exposure for feeders, minimizes conductor damage, and supports safer commissioning and maintenance routines in rooftop and ground-mounted PV configurations. UL 489 certification underpins safety and compliance for molded case breakers used in electrical protection schemes, including PVGuard installations. As part of the Series G PV protection family, the JGSDC3090FAW integrates with Eaton’s broader protection ecosystem for scalable solar deployments. The unit weighs about 6.5 lb and measures 3.44 in by 7.0 in by 4.13 in, balancing rugged performance with compact form for space-constrained panels. Warranty follows Eaton policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first.

Get a Quick Quote for a Eaton JGSDC3090FAW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton JGSDC3090FAW? Enquire Now

FAQs

The JGSDC3090FAW is a three‑pole device designed for PV DC protection within Eaton’s PVGuard ecosystem. Install in compatible enclosure spaces, noting that terminals are not included on the unit. Use approved external terminations or lugs as specified by Eaton. Verify voltage ratings (600 Vac / 250 Vdc), ensure 50/60 Hz operation, and perform a functional trip test after wiring to confirm coordination with nearby protective devices.
Key ratings include a 90 A amperage rating, 600 Vac and 250 Vdc voltage ratings, and 50/60 Hz frequency. The trip type is T185, with interrupt ratings of 85 kAIC at 240 Vac, 35 kAIC at 480 Vac, and 18 kAIC at 600 Vac. It is a three-pole JG frame device, designed for reliability in PV protection and DC distribution networks.
Yes. The JGSDC3090FAW is part of Eaton’s PVGuard line, specifically designed for PV solar protection and DC distribution. Its three-pole configuration, 90 A rating, and UL 489 certification make it suitable for PV arrays, DC combiner boxes, and inverter interfaces. Note that terminals are not included, so plan for external terminations and compatible accessories.
The JGSDC3090FAW carries UL 489 certification, confirming safety and performance compliance for molded case circuit breakers used in protection systems, including PVGuard installations. It supports 50/60 Hz operation and the specified voltage ratings, aligning with standard industrial safety practices for PV protection and electrical distribution.
Expected ROI comes from improved protection reliability and reduced downtime in PV systems. The unit’s UL 489 certification and PVGuard compatibility simplify compliance and maintenance planning. The warranty follows Eaton policy 25-000 (one year from installation or 18 months from shipment). Regular inspection of trip settings and periodic functional testing help sustain long-term performance.