Eaton JGU3080AAG Molded Case Breaker - UL Listed, 200kAIC

Part Number: JGU3080AAG
Manufacturer
Eaton
Part number
JGU3080AAG

Quick Summary

The Eaton JGU3080AAG molded case breaker delivers precise overcurrent protection for industrial electrical distribution panels. In busy plant environments, selecting a device that fits tight spaces yet provides reliable protection can be a major challenge. This unit carries UL Listed, CE Marked, and CSA Certified approvals, along with IEC ratings, ensuring regulatory compliance across global sites. Built on the Series G platform with an adjustable thermal and magnetic trip, it enables selective protection for three-pole circuits while supporting streamlined installation and lower lifecycle costs. Its compact form and line/load terminals simplify mounting and wiring, accelerating commissioning and reducing field retrofit time for panel builders and machine integrators.

Product Information

Extended Description

JGU3080AAG Eaton: Eaton Series G molded case circuit breaker, JG-frame, JG, Adjustable thermal, adjustable magnetic trip, Three-pole, 80A, 600 Vac, 250 Vdc, 200 kAIC at 240 Vac, 150 kAIC at 480 Vac, 50 kAIC at 600 Vac, Line and load, 50/60 Hz
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
JGU3080AAG
UPC
786685126791
Product Length/Depth
3.44 in
Product Height
7 in
Product Width
4.13 in
Product Weight
6 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
CE Marked
Certifications
UL Listed IEC Rated CSA Certified
Type
Complete breaker
Amperage Rating
80 A
Voltage rating
600 Vac, 250 Vdc
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
JG
Circuit breaker frame type
Complete breaker
Series
Series G
Terminals
Line and load
Frame
JG
Frequency rating
50/60 Hz
Interrupt rating
200 kAIC at 240 Vac 150 kAIC at 480 Vac 50 kAIC at 600 Vac
Number of poles
Three-pole
With an 80 A rating, the JGU3080AAG provides precise protection for motor, pump, and feeder circuits, reducing nuisance trips and preserving equipment life. This targeted protection improves uptime by ensuring smaller devices aren't tripped by inrush or transient faults. In practice, panel builders install it in machine-control enclosures and distribution panels where predictable, selective protection is essential for consistent production. Rated for 600 Vac and 250 Vdc, the MCCB supports both AC and DC control circuits common in modern plants, simplifying sourcing and spares inventory. The broad voltage capability translates to fewer part numbers while maintaining safe shutdown margins across equipment types. For users, this means faster design cycles and improved compliance when panels serve mixed-voltage loads in process plants and packaging lines. With a three-pole configuration and line/load terminations, wiring is straightforward, reducing field wiring errors and installation time. The JG frame promotes modular assembly, aiding panel designers in achieving neat, reproducible layouts. In applications such as automotive assembly lines or packaging machines, the compact footprint helps fit dense panels without sacrificing performance. Adjustable thermal and magnetic trip enables tailored selectivity, helping coordinate breakers across multiple branches and feeders. This capability minimizes the risk of cascading trips during fault conditions and supports faster fault isolation. For integrators, it means better coordination with upstream protections and lower total cost of ownership through extended equipment life and reduced maintenance. Interrupt ratings of 200 kAIC at 240 Vac, 150 kAIC at 480 Vac, and 50 kAIC at 600 Vac demonstrate robust fault-current capability for demanding facilities. In data centers, process plants, or heavy manufacturing, this translates to safer, more reliable protection of feeders and subcircuits. Series G construction and UL/CE/CSA certifications further reassure procurement teams that the product meets global standards. Compact dimensions (3.44 in L x 7 in H x 4.13 in W) and a 6 lb weight simplify installation in space-constrained panels, while line and load terminals support straightforward wiring and future upgrades. The combination of these physical and electrical attributes accelerates commissioning, reduces retrofit time, and lowers total installed cost for panel builders and OEMs.

Get a Quick Quote for a Eaton JGU3080AAG

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton JGU3080AAG? Enquire Now

FAQs

The JGU3080AAG uses the JG frame and three-pole design with line and load terminals, making it a direct fit for Series G MCCB installations. Its compact 3.44 in L x 7 in H x 4.13 in W footprint and 6 lb weight simplify panel layouts, enabling straightforward mounting and clean wiring in machine control cabinets.
Key ratings include an 80 A amperage, 600 Vac and 250 Vdc voltage ratings, and a trip type of adjustable thermal and magnetic. It provides 200 kAIC at 240 Vac, 150 kAIC at 480 Vac, and 50 kAIC at 600 Vac, supporting diverse fault-current conditions across 50/60 Hz systems.
Yes. The unit is specified for 50/60 Hz operation, ensuring compatibility with typical industrial power systems. This makes it suitable for machinery, conveyors, and process lines that require reliable protection across standard utility and plant electrical environments.
The JGU3080AAG is UL Listed, CE Marked, and CSA Certified, and IEC Rated. These certifications provide global compliance, broader market eligibility, and proven safety performance for control panels deployed in multinational facilities.
To maximize ROI, ensure proper torque on line/load terminals, use matching accessories from Series G where applicable, and coordinate with upstream protection for selective tripping. Regular inspection of thermal magnetic trip settings and periodic refurbishment of panel wiring help sustain uptime and reduce unexpected outages.