Eaton JGU8200AAG Complete Molded Case Circuit Breaker - UL Listed

Part Number: JGU8200AAG
Manufacturer
Eaton
Part number
JGU8200AAG

Quick Summary

The Eaton JGU8200AAG complete molded case circuit breaker protects 600 V industrial power systems with precise, adjustable thermal and magnetic trip. For engineers, the challenge is delivering reliable overcurrent protection without sacrificing panel space or uptime during maintenance. CE Marked, UL Listed, and CSA Certified, it supports global compliance and safer coordination across panels, machines, and control systems. Designed for control panels and machine builders, the JGU8200AAG combines dependable protection with easy mounting and predictable maintenance, delivering cost efficiency across the lifecycle. The JG frame and metric mounting simplify retrofits and enable scalable protection strategies for future upgrades. This MCCB supports line-and-load connectivity in a compact footprint, helping OEMs optimize space and reduce wiring complexity.

Product Information

Extended Description

JGU8200AAG Eaton: Eaton Series G molded case circuit breaker, JG-frame, JG, Complete breaker, Adjustable thermal, adjustable magnetic trip, Four-pole, 200A, 600 Vac, 200 kAIC at 240 Vac, 150 kAIC at 415/480 Vac, 50 kAIC at 600 Vac, Line and load, Metric
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
JGU8200AAG
UPC
786685127446
Product Length/Depth
3.57 in
Product Height
5.34 in
Product Width
5.34 in
Product Weight
8 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
CE Marked
Certifications
IEC Rated CSA Certified UL Listed
Type
Complete breaker
Amperage Rating
200 A
Voltage rating
600 Vac
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
JG
Circuit breaker frame type
Complete breaker
Terminals
Line and load
Frame
JG
Mounting hardware
Metric
Interrupt rating
150 kAIC at 415/480 Vac 50 kAIC at 600 Vac 200 kAIC at 240 Vac
Number of poles
Four-pole
With a 200 A rating and 600 Vac capability in a four-pole design, this MCCB ensures robust protection for feeders and motors. That capability translates to improved coordination across three-phase circuits and reduced nuisance trips, safeguarding uptime and extending equipment life. It's ideal for control panels in manufacturing lines, machine centers, and process plants where reliable protection is non-negotiable. Adjustable thermal and magnetic trip provides selective protection, enabling downstream devices to trip before upstream equipment and minimizing impact on overall production. This improves machine availability and reduces unplanned downtime in high-demand environments. The JG frame, line-and-load terminals, and metric mounting deliver straightforward installation, predictable wiring, and compatibility with existing Eaton Series G components. installers benefit from standardized hardware and faster commissioning. Certifications and documented performance support global deployments and cross-border sourcing, simplifying procurement and compliance. The unit’s compact footprint and 8 lb weight aid space planning and handling during installation, movement between panels, and routine maintenance.

Get a Quick Quote for a Eaton JGU8200AAG

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton JGU8200AAG? Enquire Now

FAQs

JGU8200AAG uses a four-pole, complete breaker with line and load terminals in a metric mounting frame. It fits Eaton Series G MCCB installations and standard metric enclosures. It supports three-phase power distribution with line/load connectivity, and its JG frame aligns with compatible MCCB bus and mounting kits, simplifying retrofit and panel modernization. Ensure enclosure space accounts for the 5.34 in width and height and adheres to torque specs per Eaton guidelines.
Trip adjustments are performed per the Eaton Series G MCCB guidelines. Use the provided adjustment screws to set the thermal (amp setting) and magnetic (short-circuit response) trips within the device’s rated range. Refer to the MOEM MCCB product selection guide and the JGU8200AAG datasheet for torque specifications, acceptable ranges, and safety precautions to ensure proper coordination with downstream protection.
Yes. The JGU8200AAG is CE Marked, UL Listed, and CSA Certified, reflecting compliance with international safety and performance standards. This enables global sourcing, simplifies panel approvals, and supports coordinated protection across multiple regions for OEMs and integrators.
Interrupt ratings are 200 kAIC at 240 Vac, 150 kAIC at 415/480 Vac, and 50 kAIC at 600 Vac, with four-pole protection and line-and-load terminals. These ratings support robust fault current handling in varied 3-phase applications and facilitate safe upstream protection coordination.
Warranty is Eaton’s standard policy: one year from installation or eighteen months from shipment, whichever occurs first. Breaker service centers and Eaton technical support are available to assist with installation, commissioning, and ongoing maintenance, helping maximize uptime and lifecycle value.