Eaton KAC-60 High Speed Fuse - UL Recognized.
Part Number: KAC-60
Quick Summary
The Eaton KAC-60 high speed fuse delivers fast overcurrent protection for motor drives and power electronics. In harsh industrial environments, choosing a fuse that balances reliable protection with minimal downtime is challenging. This device is CE Marked and UL Recognized, aligning with global safety standards for global installations. With a 600 V rating, 60 A current, and a 200 kAIC interrupt capability, it protects rectifiers and DC links while keeping production lines running. Its blade-end x blade-end connections and stud mounting simplify panel integration, helping engineers reduce wiring errors and installation time. This translates to lower maintenance costs and improved plant throughput.
Product Information
Extended Description
KAC-60 Eaton: Eaton Bussmann series Tron KAC high speed fuse, 600V, 60A, 200 kAIC, Non Indicating, High speed fuse, Blade end X blade end, Stud
Product Name
Eaton Bussmann series Tron KAC high speed fuse
Catalog Number
KAC-60
UPC
051712470605
EAN
5027590063258
Product Length/Depth
0.76 in
Product Height
4.32 in
Product Width
0.76 in
Product Weight
0.13 lb
Warranty
Not Applicable
Compliances
CE Marked
Certifications
UL Recognized
Amperage Rating
60 A
Interrupt rating
200 kAIC
Voltage rating
600 V
Packaging type
Standard
Connection
Blade end x blade end
Fuse indicator
Non Indicating
Mounting method
Stud
Feature: High-speed interruption delivers rapid fault clearance, minimizing arc energy and preserving downstream components. Business Impact: This reduces fault propagation through drives, rectifiers, and controllers, extending component life and lowering emergency repair costs. Application: Particularly effective in rectifier modules and DC link protection within automation panels and motor-drive systems. Feature: CE Marked and UL Recognized certifications provide verified compliance across markets. Business Impact: Simplifies supplier qualification, streamlines cross-border deployments, and supports regulatory audits. Application: Essential for projects in Europe, North America, and other regions with strict electrical protection requirements in automation and power conversion equipment. Feature: Electrical ratings of 600 V, 60 A, and 200 kAIC enable robust protection for high-energy circuits. Business Impact: Meets coordination strategies for selective protection, reducing nuisance trips while maintaining safety margins. Application: Suitable for 600 V motor drives, rectifiers, and DC link protection in industrial automation and process control systems. Feature: Blade-end x blade-end connections with stud mounting offer flexible installation options. Business Impact: Enables drop-in replacement in existing Bussmann Tron KAC holders and simplifies retrofits, cutting panel downtime. Application: Compatible with standard fuse holders and panel mounting schemes in control cabinets and equipment racks. Feature: Non-indicating fuse indicator reduces panel clutter and simplifies sourcing. Business Impact: With external diagnostics, maintenance planning improves and misreads decrease. Application: Ideal for systems with remote monitoring or where status is provided via separate indicators in the control system. Additional note: Engineers value interoperability and lifecycle support; KAC-60’s combination of ratings, certifications, and mechanical design aligns with typical OEM specifications for reliability and cost efficiency.
Get a Quick Quote for a Eaton KAC-60
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton KAC-60?
Enquire Now
FAQs
KAC-60 uses blade end x blade end connections with a stud mounting method, enabling straightforward drop-in installation in standard Bussmann Tron KAC holders and panel-mounted fuse blocks. Verify correct torque on mounting stud and ensure clearance for 600 V circuitry to prevent arcing. Use external diagnostics for status if non-indicating units are used.
The 60 A current rating combined with a 200 kAIC interrupt rating provides fast, reliable interruption of fault energy in rectifier modules, reducing arc duration and protecting downstream components. Its compact blade-end/stud mounting supports easy retrofits in existing installations.
Yes. The KAC-60 is CE Marked and UL Recognized, assuring compliance with European and North American safety standards and simplifying multi-region deployments in industrial facilities.
Industries employing motor drives, rectifiers, and DC link systems—such as automotive, plastics, metals, and packaging—benefit from its fast protection, high interrupt rating, and ease of integration within 600 V control panels.
By minimizing downtime through rapid fault clearance, extending component life, and simplifying installation, the KAC-60 reduces maintenance costs and accelerates commissioning, delivering a favorable total cost of ownership for power protection in automation equipment.