Eaton LDC3600CVH09 Molded Case Circuit Breaker - UL 489

Part Number: LDC3600CVH09
Manufacturer
Eaton
Part number
LDC3600CVH09

Quick Summary

Molded Case Circuit Breaker, the Eaton LDC3600CVH09 protects power circuits in industrial automation panels. Engineers often struggle with nuisance trips and limited protection margins in high‑demand equipment; this MCCB delivers reliable, calibrated protection with fixed thermal magnetic trip for consistent performance in demanding environments. UL 489 certification, Naval class, and a 50°C rating ensure compliance and resilience where equipment operates at elevated temperatures. Designed for 50/60 Hz systems and 600 Vac / 250 Vdc applications, it integrates with Series C architectures to simplify sourcing and installation. By combining robust protection with a compact footprint, it supports safer panel design, faster commissioning, and predictable maintenance costs for industrial facilities.

Product Information

Extended Description

LDC3600CVH09 Eaton: Eaton Series C complete molded case circuit breaker, L-frame, LDC, Complete breaker, Fixed thermal, fixed magnetic trip, Three-pole, 600A, 600 Vac, 250 Vdc, 200 kAIC at 240 Vac, 100 kAIC at 480 Vac, Copper, Naval, 50°C, 50/60 Hz
Product Name
Eaton Series C complete molded case circuit breaker
Catalog Number
LDC3600CVH09
UPC
786679081891
Product Length/Depth
8.25 in
Product Height
8.25 in
Product Width
4.06 in
Product Weight
0.01 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL 489
Amperage Rating
600 A
Voltage rating
600 Vac, 250 Vdc
Trip Type
T186
Circuit breaker type
LDC
Circuit breaker frame type
Complete breaker
Series
Series C
Frame
L
Frequency rating
50 to 60 Hz
Class
Naval
Calibration
50°C
Terminal material
Copper
Interrupt rating
100 kAIC at 480 Vac 200 kAIC at 240 Vac
Number of poles
Three-pole
Amperage rating and interrupt capability enable load protection with minimal nuisance trips; this reduces downtime and protects critical motors in high‑demand applications, delivering a clear business advantage in manufacturing lines and distribution centers. The 600 A, 600 Vac / 250 Vdc rating paired with fixed thermal magnetic trip provides fast, predictable fault clearing, improving equipment lifespan and safety in motor control centers and panels. The L-frame, Series C complete breaker design simplifies interchangeability, enabling faster replacements and lower spare parts inventory while maintaining compliance with UL 489. Copper terminal construction improves conductivity and reliability under load, supporting long service life in harsh industrial environments. The naval class and 50°C calibration extend applicability to maritime and coastal facilities, where environmental stresses and space constraints are common. Compatible with 50/60 Hz grids, it streamlines commissioning in mixed-generation facilities and OEM builds. The compact footprint (8.25 in L x 4.06 in W x 8.25 in H) fits tight panel enclosures without sacrificing protection, reducing panel size and installation costs while delivering consistent trip performance across temperature ranges.

Get a Quick Quote for a Eaton LDC3600CVH09

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton LDC3600CVH09? Enquire Now

FAQs

The LDC3600CVH09 is a three-pole, L-frame, complete breaker designed for Series C MCCB applications. It features copper terminals and a footprint of 8.25 in length and height with a 4.06 in width, enabling straightforward drop‑in installation in standard control panels. It’s compatible with 50/60 Hz systems and supports 600 Vac / 250 Vdc operations, simplifying panel upgrades and replacements.
Key specs include a 600 A amperage rating, 600 Vac and 250 Vdc voltage ratings, and a fixed thermal magnetic trip (T186). It provides 100 kAIC at 480 Vac and 200 kAIC at 240 Vac interrupt ratings, with a three-pole configuration and Series C/L frame. These ratings support reliable protection for high‑demand loads in industrial settings.
Yes. The product is specified with Naval class designation and is calibrated for 50°C operation, making it well suited for harsh environments including marine applications. Its UL 489 certification further supports compliance in safety‑critical panel installations typical of naval equipment and maritime facilities.
LDC3600CVH09 carries UL 489 certification, ensuring the breaker meets recognized safety and performance standards for molded case circuit breakers. The Naval class designation and 50°C calibration provide additional assurance for environments with higher ambient temperatures and demanding service conditions, supporting reliable protection and uptime in industrial and maritime installations.
The unit is covered by Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. Routine maintenance includes periodic inspection of terminals and trip settings, and replacement of worn components as part of standard preventive maintenance for MCCBs in industrial panels to sustain reliability and performance.