Eaton LGE3600FAWX19Y1 Molded Case Breaker - UL Listed

Part Number: LGE3600FAWX19Y1
Manufacturer
Eaton
Part number
LGE3600FAWX19Y1

Quick Summary

Eaton LGE3600FAWX19Y1 Molded Case Breaker provides reliable overcurrent protection for industrial control panels. Many facilities struggle with nuisance trips, space constraints, and maintenance challenges in compact control enclosures. The UL Listed device is HACR rated, supporting safe operation in HVAC and refrigeration environments, and it aligns with the LG-series G design for consistent coordination with existing protection schemes. With a 600 A rating at 600 Vac and an adjustable magnetic trip, it optimizes protection without unnecessary feeder oversizing. The line/load terminal option and compact LG frame support flexible panel design, reducing inventory complexity while enabling scalable protection strategies in modern electrical ecosystems. This model is ideal for panel builders and maintenance teams seeking robust, compliant MCCB solutions.

Product Information

Extended Description

LGE3600FAWX19Y1 Eaton: Eaton Series G molded case circuit breaker, LG-frame, LG, Fixed thermal, adjustable magnetic trip, Three-pole, 600A, 600 Vac, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 18 kAIC at 600 Vac, No terminals, optional line or load, 50/60 Hz
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
LGE3600FAWX19Y1
UPC
786685954646
Product Length/Depth
4.09 in
Product Height
5.48 in
Product Width
5.48 in
Product Weight
13.5 lb
Certifications
UL Listed
Catalog Notes
LG breaker is HACR rated
Amperage Rating
600 A
Voltage rating
600 Vac
Trip Type
T185
Circuit breaker type
LG
Circuit breaker frame type
Complete breaker
Series
Series G
Terminals
Without terminals, optional line or load
Frame
LG
Frequency rating
50 to 60 Hz
Interrupt rating
35 kAIC at 480 Vac 18 kAIC at 600 Vac 65 kAIC at 240 Vac
Number of poles
Three-pole
Feature: LG-frame Series G molded case breaker delivers compact, standardized protection for control panels. Business Impact: simplifies panel design and stocking while enabling reliable fault isolation. Application: suitable for industrial cabinets where space is at a premium. Feature: 600 A amperage rating at 600 Vac with multiple interrupt ratings. Business Impact: supports heavy motor loads and high-inrush equipment with precise fault clearing, reducing equipment damage and downtime. Application: main feeders and branch protections in manufacturing lines. Feature: Trip Type T185 with adjustable magnetic trip. Business Impact: enables precise coordination for motor-control centers and critical loads, minimizing nuisance trips and improving selectivity. Application: panel protection for conveyors, presses, and machine tools. Feature: Three-pole LG frame with optional line or load terminals. Business Impact: flexible integration into existing bus configurations and ease of retrofits without large enclosure modifications. Application: retrofit projects and new installations in standard industrial panels. Feature: 50/60 Hz frequency range and UL Listed HACR rating. Business Impact: ensures compatibility across global sites and compliance with safety standards for HVAC, refrigeration, and general electrical protection. Application: international panel assemblies and mixed-load environments. Feature: Dimensions and weight (4.09 in depth, 5.48 in height/width, 13.5 lb). Business Impact: predictable fitment in compact enclosures and manageable installation/removal. Application: control panels with tight spacing and modular MCCB blocks.

Get a Quick Quote for a Eaton LGE3600FAWX19Y1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton LGE3600FAWX19Y1? Enquire Now

FAQs

The LGE3600FAWX19Y1 uses a three-pole LG frame and can be configured without terminals or with optional line or load terminals. This flexibility supports easy integration into existing bus setups and simplifies retrofit work in standard industrial panels without requiring major enclosure restructuring.
The breaker provides 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, and 18 kAIC at 600 Vac, with a 600 A amperage rating. These ratings enable selective protection for mixed-voltages in panel assemblies and help minimize downtime during fault events.
Yes. With a T185 trip type and LG-frame design, the unit supports motor control applications by providing accurate magnetic trips that align with motor inrush and load characteristics, improving coordination and reducing nuisance trips in motor-driven systems.
The breaker is UL Listed and HACR rated, ensuring compliance with safety standards for general electrical protection and HVAC/refrigeration applications. These certifications help meet local and industrial codes, simplify procurement approvals, and support safer panel operation.
Given its compatibility with Series G protection schemes and optional terminals, keep spares for line/load configurations and standard MCCB consumables. The unit’s robust LG-frame design and known interrupt ratings support predictable lifecycle planning, reducing unplanned maintenance and facilitating faster replacement in critical panels.