Eaton LGH3600FAGC Complete MCCB - 600A UL Listed
Part Number: LGH3600FAGC
Quick Summary
Eaton Series G molded case circuit breaker is a reliable protection device for electrical distribution panels and motor control applications. Engineers often wrestle with nuisance trips, coordination challenges, and space constraints in modern switchgear. This unit is UL Listed, CSA Certified, and IEC Rated, assuring global compliance and safer operation. With a 600 A rating and LG-frame design, it delivers 100% rated performance in compact assemblies, reducing lifecycle costs. Fixed thermal, adjustable magnetic trip enables precise coordination with downstream protections, helping you avoid unnecessary downtime. The device also supports efficient installation in metric mountings and uses line/load copper terminals designed for reliability.
Product Information
Extended Description
LGH3600FAGC Eaton: Eaton Series G molded case circuit breaker, LG-frame, LG, Fixed thermal, adj. magnetic trip, Three-pole, 600A, 600 Vac, 100 kAIC at 240 Vac, 70 kAIC at 415 Vac, 65 kAIC at 480 Vac, 35 kAIC at 600 Vac, Copper, Line/load, Metric, 100% rated
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
LGH3600FAGC
UPC
786685291352
Product Length/Depth
5.48 in
Product Height
5.48 in
Product Width
5.48 in
Product Weight
16 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
CE Marked
Certifications
UL Listed IEC Rated CSA Certified
Catalog Notes
LG breaker is HACR rated
Type
Complete breaker
Amperage Rating
600 A
Voltage rating
600 Vac
Trip Type
T185
Circuit breaker type
LG
Circuit breaker frame type
Complete breaker
Rating
100% rated
Terminals
Line and load
Frame
LG
Mounting hardware
Metric
Terminal material
Copper
Interrupt rating
65 kAIC at 480 Vac 70 kAIC at 415 Vac 35 kAIC at 600 Vac 100 kAIC at 240 Vac
Number of poles
Three-pole
Application of Multi-Wire Terminals for Molded Case Circuit Breakers
Application of Multi-Wire Terminals for Molded Case Circuit Breakers
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
Breaker service centers
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
NG and ND-Frame molded case circuit breakers
NG and ND-Frame molded case circuit breakers
NG and ND-Frame molded case circuit breakers
The LG-frame complete breaker uses fixed thermal and adjustable magnetic trip to deliver precise overload protection. This feature translates to selective coordination with upstream and downstream devices, reducing nuisance trips and unplanned downtime in critical processes. In practice, it provides reliable motor protection in demanding industrial panels, while delivering predictable trip curves under varying electrical loads. With a 600 A amperage rating and 600 Vac voltage rating, the LGH3600FAGC accommodates large feeders and high inrush scenarios found in manufacturing lines and data-center support equipment. Its interrupt ratings at multiple voltages—65 kAIC at 480 Vac, 70 kAIC at 415 Vac, 35 kAIC at 600 Vac, and 100 kAIC at 240 Vac—offer robust fault-current protection aligned to system standards and short-circuit requirements. This combination supports safer, more compliant panel design and reduces the need for oversized protective devices. Copper line and load terminals, metric mounting hardware, and the LG-frame construction simplify installation and future maintenance. At 5.48 in dimensions and a 16 lb weight, it fits compact panel spaces while maintaining robust mechanical durability across operating conditions. The fixed 3-pole design further supports balanced protection across three-phase systems. The unit is UL Listed, CSA Certified, and IEC Rated, with CE Marked compliance for international acceptance. Eaton's warranty policy—one year from installation or eighteen months from shipment—provides coverage during commissioning and early operation, helping procurement teams justify the investment. In addition, 100% rated performance and HACR suitability align with modern control architectures where reliability and energy efficiency are critical.
Get a Quick Quote for a Eaton LGH3600FAGC
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton LGH3600FAGC?
Enquire Now
FAQs
To install the LGH3600FAGC, align the unit with the panel’s designated LG-frame space and use metric mounting hardware for secure attachment. Connect the line and load terminals using copper conductors sized per ampacity; ensure three-pole wiring is balanced to maintain coordination. Verify clearance and torque specs from the manufacturer’s installation notes, and check that the device sits properly in the intended slot to avoid overheating.
LGH3600FAGC combines fixed thermal protection with an adjustable magnetic trip, enabling precise overload and short-circuit protection for three-phase motors. Its 600 A rating and 600 Vac operating range handle large feeders and motor inrush, while HACR-rated design aligns with HVAC and motor-control applications. This results in fewer nuisance trips and improved protection coordination across downstream devices.
The LGH3600FAGC is UL Listed, CSA Certified, and IEC Rated, with CE marking for international markets. These certifications verify safety, reliability, and interoperability with global standards, simplifying procurement across regions and ensuring panel designs meet regulatory requirements for building codes and electrical installation practices.
Interrupt ratings for the LGH3600FAGC vary by voltage: 65 kAIC at 480 Vac, 70 kAIC at 415 Vac, 35 kAIC at 600 Vac, and 100 kAIC at 240 Vac, providing robust fault-current protection across typical industrial feeders. This enables selective coordination, reduces the risk of collateral damage, and supports compliant protection schemes in diverse electrical systems.
Eaton offers a warranty of one year from installation or eighteen months from shipment for the LGH3600FAGC (whichever occurs first). This coverage helps mitigate commissioning risks and supports total cost of ownership decisions. Excellent service support, coupled with recognized certifications, can shorten downtime during maintenance and improve long-term system uptime.