Eaton LGU3500AAG MCCB - 600 Vac, 500 A, UL Listed

Part Number: LGU3500AAG
Manufacturer
Eaton
Part number
LGU3500AAG

Quick Summary

The Eaton LGU3500AAG MCCB delivers adjustable thermal and magnetic overcurrent protection for three-pole LG-frame breakers in 600 Vac systems, making it an ideal choice for control panels, machine feeders, and critical motor circuits. This addresses a common pain point—nuisance trips and unexpected downtime—by enabling precise trip settings that tailor protection to motor starting, inrush, and short-circuit events, reducing unplanned outages. Key certifications include UL Listed, HACR rating, and IEC-market compatibility notes that help with global designs while supporting local requirements. Together with solid documentation and service options, LGU3500AAG translates into faster installation, easier maintenance, and clearer total-cost-of-ownership for panel builders and OEMs.

Product Information

Extended Description

LGU3500AAG Eaton: Eaton Series G molded case circuit breaker, LG-frame, LG, Adjustable thermal, adjustable magnetic trip, Three-pole, 500A, 600 Vac, 200 kAIC at 240 Vac, 150 kAIC at 415 Vac, 150 kAIC at 480 Vac, 65 kAIC at 600 Vac, Line and load, Metric
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
LGU3500AAG
UPC
786685184951
Product Length/Depth
5.48 in
Product Height
5.48 in
Product Width
5.48 in
Product Weight
11.9 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Adjustable thermal, adjustable magnetic trip units are typically used in IEC markets and are not UL or CSA listed, LG breaker is HACR rated
Type
Complete breaker
Amperage Rating
500 A
Voltage rating
600 Vac
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
LG
Circuit breaker frame type
Complete breaker
Terminals
Line and load
Frame
LG
Mounting hardware
Metric
Interrupt rating
200 kAIC at 240 Vac 65 kAIC at 600 Vac 150 kAIC at 415 Vac 150 kAIC at 480 Vac
Number of poles
Three-pole
Feature: Adjustable thermal and magnetic trip units. Business Impact: Enables tailored protection curves to match motor inrush, startup behavior, and fault conditions, reducing nuisance trips and extending equipment life. Application: Ideal for control panels and machine feeders where precise coordination improves uptime and safety. Feature: LG-frame three-pole design with 500 A rating. Business Impact: Provides compact, robust protection for high-current circuits while minimizing enclosure depth. Application: Main feeders and three-phase circuits in industrial panels where space is at a premium. Feature: Line and load terminals with metric mounting. Business Impact: Simplifies installation and maintenance by using standardized terminations and mounting hardware, shortening commissioning time. Application: Field upgrades and new panel builds across industrial facilities. Feature: High interrupt ratings across voltages (200 kAIC at 240 Vac, 150 kAIC at 415/480 Vac, 65 kAIC at 600 Vac). Business Impact: Enhances safety margins and fault-handling capability in demanding production environments, reducing arc-flash risk and downtime. Application: Heavy-duty machine lines and distribution panels. Feature: Certifications and market compatibility (UL Listed, HACR rated, IEC emphasis). Business Impact: Supports compliance across multiple regions, easing design approvals and supplier audits. Application: Global deployments and cross-market projects. Feature: Compact footprint and weight (5.48 in each dimension, 11.9 lb). Business Impact: Saves enclosure space and supports modular panel design with straightforward substitutions. Application: Replacements and new builds where space is constrained. Industry context: Real-world installations benefit from comprehensive documentation, quick-start guides, and proven selectivity with Series G devices, enabling faster commissioning and predictable maintenance cycles.

Get a Quick Quote for a Eaton LGU3500AAG

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton LGU3500AAG? Enquire Now

FAQs

The LGU3500AAG uses line and load terminals and metric mounting hardware, designed for straightforward integration into LG-frame panels. Its compact 5.48 in footprint supports space-constrained layouts, while the three-pole design aligns with standard three-phase bus arrangements, simplifying retrofits and new builds alike.
Key specs include a 500 A amperage rating, 600 Vac voltage rating, and adjustable thermal and magnetic trip units. Interrupt ratings vary by voltage: 200 kAIC at 240 Vac, 150 kAIC at 415/480 Vac, and 65 kAIC at 600 Vac, enabling selective coordination and robust fault handling in industrial environments.
Yes. While the unit is UL Listed and HACR rated, its catalog notes indicate compatibility with IEC markets, supporting global designs. This makes it a versatile choice for multinational installations where regional requirements differ but protection performance remains consistent.
The product carries UL Listed certification and HACR rating, with additional IEC-market considerations noted in catalog notes. Comprehensive datasheets and application notes are available to support engineering approvals, maintenance planning, and safety compliance during commissioning.
With adjustable trip settings, reliable UL/HACR certification, and a 500 A / 600 Vac rating, the LGU3500AAG reduces nuisance trips and downtime, shortening maintenance windows and boosting panel uptime. The one-year Eaton warranty and accessible service centers further reduce lifecycle costs through predictable replacements and support.