Eaton LPN-RK-600SP Fuse - Class RK1 Time-Delay

Part Number: LPN-RK-600SP
Manufacturer
Eaton
Part number
LPN-RK-600SP

Quick Summary

Eaton Bussmann LPN-RK-600SP fuse provides reliable time-delay, dual-element protection for electrical panels and motor circuits. This design helps mitigate nuisance trips and downtime caused by short-term inrush or fault conditions. It carries CE Marked and RoHS compliant certifications, supporting regulatory compliance in global installations. Class RK1 coordination, with current-limiting technology, means safer, more predictable protection for downstream equipment. In practice, this fuse delivers robust protection with straightforward integration in blade-end DC/AC systems, while offering a favorable total cost of ownership through reduced maintenance and longer service intervals.

Product Information

Extended Description

LPN-RK-600SP Eaton: Eaton Bussmann Series Class RK1 fuse, LPN-RK, time-delay, dual-element, current limiting fuse, 600 A, non-indicating fuse, interrupting rating of 300 kA at 250 Vac and 100 kA at 125 Vdc
Product Name
Eaton Bussmann series LPN-RK fuse
Catalog Number
LPN-RK-600SP
UPC
051712538589
Product Length/Depth
10.38 in
Product Height
2.88 in
Product Width
2.88 in
Product Weight
3.25 lb
Warranty
Not Applicable
Compliances
CE Marked RoHS Compliant
Amperage Rating
600 A
Interrupt rating
300 kAIC at 250 Vac 100 kAIC at 250 Vdc
Voltage rating
250 Vac, 250 Vdc
Fuse type
Time delay Current-limiting
Number of elements
Dual
Packaging type
Standard
Class
Class RK1
Connection
Blade end x blade end
Fuse indicator
Non-indicating
Quantity
1
Special features
Electrically isolated end cap
Feature → Business Impact → Application: Time-delay, dual-element design provides selective interruption during transient faults and reduced nuisance trips, improving line continuity in motor drives and feeders. This translates to lower downtime and fewer unplanned maintenance events in industrial environments; ideal for panel protection and control circuits. Feature → Application compatibility → The LPN-RK-600SP uses blade end x blade end connections and electrically isolated end caps, enabling quick drop-in installation in standard enclosures and safer wiring practices, reducing field rework. Feature → Benefits of current-limiting with high interrupt capability → In a fault condition, the fuse limits arc energy, protecting personnel and surrounding equipment, while maintaining reliability in 250 Vac and 250 Vdc applications. Feature → Certifications and compliance → CE Marked and RoHS compliant product supports global regulatory requirements, easing procurement and documentation for modern plant standards. Feature → Class RK1 and non-indicating operation → Predictable coordination with upstream fuses and minimal visual maintenance, improving reliability in high-density electrical panels. Feature → Technical performance → With 600 A rating and 300 kAIC at 250 Vac, this device meets demanding industrial protection needs, supporting efficiency gains and safer operations.

Get a Quick Quote for a Eaton LPN-RK-600SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton LPN-RK-600SP? Enquire Now

FAQs

Yes. The fuse uses blade end x blade end connections and comes with an electrically isolated end cap, allowing straightforward drop-in installation in common panel layouts without special adapters.
It is rated for 600 A, with an interrupt rating of 300 kAIC at 250 Vac and 100 kAIC at 125 Vdc, and a voltage rating of 250 Vac / 250 Vdc, making it suitable for high-demand AC and DC circuits.
Best suited for electrical protection in switchgear, motor control centers, control panels, and feeders where inrush conditions occur, providing selective protection while minimizing nuisance trips.
The device is CE Marked and RoHS compliant, aligning with common regulatory and environmental requirements for global installations.
Its dual-element, time-delay design reduces nuisance trips from inrush, while current-limiting minimizes arc energy, lowering downtime and maintenance costs; the non-indicating form simplifies inspections and the electrically isolated end caps enhance safety during servicing.