Eaton LPS-RK-60SPI Fuse - RK1 Time-Delay, 600V

Part Number: LPS-RK-60SPI
Manufacturer
Eaton
Part number
LPS-RK-60SPI

Quick Summary

Eaton LPS-RK-60SPI fuse provides protection for industrial control panels and machine feeders. Nuisance trips, slow fault diagnosis, and difficult coordination across drives are common pain points in automation environments that this device helps mitigate. CE marking confirms compliance with safety standards, and the RK1 class design with dual-element time-delay protection enables fast fault clearing in demanding installations. With a 60 A rating and 600 Vac operating range, it supports motor control, panel upgrades, and energy-management initiatives while maintaining high availability across critical lines.

Product Information

Extended Description

LPS-RK-60SPI Eaton: Eaton Bussmann Series Class RK1 fuse, LPS-RK, time-delay, dual-element, current limiting fuse, 60 A, indicating fuse, interrupting rating of 300 kA at 600 Vac
Product Name
Eaton Bussmann series LPS-RK fuse
Catalog Number
LPS-RK-60SPI
UPC
051712626309
Product Length/Depth
5.5 in
Product Height
1.06 in
Product Width
1.06 in
Product Weight
2.6 lb
Warranty
Not Applicable
Compliances
CE Marked
Amperage Rating
60 A
Interrupt rating
100 kAIC at 300 Vdc 300 kAIC at 600 Vac
Response time
10 sec at 500%
Voltage rating
600 Vac, 300 Vdc
Fuse type
Time delay Current-limiting
Number of elements
Dual
Packaging type
Standard
Class
Class RK1
Connection
Ferrule end x ferrule end
Fuse indicator
Non-indicating With Indicator
Quantity
10
Special features
Electrically isolated end cap
Time-delay, dual-element design provides selective fault handling, absorbing short surges without nuisance trips and reducing unplanned downtime in motor circuits and conveyors. This translates to faster line restart times, improved equipment availability, and lower maintenance costs in automated production lines. The current-limiting feature reduces fault energy, protecting downstream devices and enabling smaller conductor sizing where appropriate, which lowers total installed cost in control panels and machine tools. The high interrupt rating of up to 300 kAIC at 600 Vac ensures safe interruption in panels feeding large loads, enhancing safety and reliability for main feeders and transformer-equipped systems. Ferrule-end connections simplify installation with common terminal hardware, while an optional indicator aids quick fault localization during maintenance. Electrically isolated end caps reduce shock risk during service, supporting safer, faster commissioning and testing in industrial settings. All of this aligns with RK1-class performance and CE compliance to meet modern automation standards.

Get a Quick Quote for a Eaton LPS-RK-60SPI

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton LPS-RK-60SPI? Enquire Now

FAQs

LPS-RK-60SPI uses ferrule-end terminations that are compatible with standard crimped ferrules and panel bus bars. When installing, verify ferrule diameter and crimp quality, tighten terminals to the manufacturer’s torque specifications, and ensure proper insulation to prevent arcing. This design simplifies replacement in crowded control panels and reduces service time during maintenance.
Key specs include a 60 A amperage rating, 600 Vac voltage rating, and a 300 kAIC interrupt capability at 600 Vac (100 kAIC at 300 Vdc). The time-delay, dual-element construction accommodates short, transient motor surges without nuisance trips, while still providing rapid fault clearance under fault conditions.
Yes. The product is designed for industrial control panels, motor drives, and power distribution devices. Its RK1 class profile, 60 A rating, and robust interrupt capacity make it well-suited for panels requiring high reliability, selective coordination, and quick fault isolation in automation environments.
The LPS-RK-60SPI fuse is CE marked, indicating compliance with European safety standards. It is built to RK1 class specifications and features a dual-element time-delay current-limiting design, supporting safe operation and regulatory alignment in modern automation projects.
The time-delay, current-limiting design reduces nuisance trips and energy waste, while the high interrupt rating enhances protection for upstream equipment. This translates to shorter maintenance windows, faster fault diagnosis with indicator options, and overall lower total-cost-of-ownership for panel assemblies and automated lines.