Eaton Open-core MD63E92ZZ Open-core transformer delivers reliable drive isolation for three-phase power distribution in industrial plants. Facilities often fight overheating, insulation wear, and unplanned downtime when ventilation is inadequate in dry-type transformers. UL Recognized certification supports safety compliance and traceability, while the open-core design paired with the DT-3 frame enhances airflow and cooling in demanding service environments. With a 63 kVA rating, 460 V primary and 460Y/266 V secondary, this transformer offers flexible integration for motor control centers, distribution panels, and drive systems. For procurement teams, the aluminum windings and a robust 150 °C rise margin translate to durable performance and lower lifecycle costs.

Product Information

Extended Description

MD63E92ZZ Eaton: Drive Isolation Transformer, Ventilated, Dry Type Distribution, DT-3, Three-phase, PV: 460 delta, Taps: 1 at +5% FCAN, 1 at -5% FCBN, SV: 460Y/266V, 150°C, 63 kVA, Al windings, Frame: 914S
Product Name
Eaton Open core-coil ventilated transformer
Catalog Number
MD63E92ZZ
UPC
786680053221
Product Length/Depth
19.12 in
Product Height
39.18 in
Product Width
26.12 in
Product Weight
474 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Recognized
Catalog Notes
Open type core and coil assembly
Coil material
Aluminum
Design
DT-3
Frame
914S
Tap size
1 at +5% FCAN, 1 at -5% FCBN
Type
Dry Type Distribution, Drive Isolation Transformer
Frequency rating
60 Hz
Phase
Three-phase
Primary voltage
460 V
Secondary Voltage
460Y/266 V
Temperature rise
150 °C rise
Volt ampere rating
63 kVA
Feature: Open-core ventilated transformer with DT-3 design and aluminum windings. Business Impact: Enhanced cooling reduces hotspots, extending winding life and lowering maintenance costs. Application: Ideal for dry-type distribution in motor control centers and factory panels. Feature: Voltage taps (+5% FCAN, -5% FCBN) provide on-site voltage compensation. Business Impact: Quick, field-adjusted voltages minimize downtime and additional equipment expenses. Application: Systems with fluctuating supplies or evolving load profiles. Feature: 63 kVA, 60 Hz, three-phase with 460 V primary and 460Y/266 V secondary. Business Impact: High-capacity, single-source solution reduces inventory complexity and supports diverse motor loads. Application: Industrial power distribution and drive circuitry. Feature: Frame 914S with aluminum windings and 150 °C rise rating. Business Impact: Robust construction enables reliable operation in demanding environments and higher ambient temps. Application: Plants with limited cooling or elevated temperatures. Feature: Open-type core and coil assembly with UL Recognized certification. Business Impact: Compliance streamlines audits and procurement approvals. Application: Safety-conscious facilities and regulated industries requiring recognized components.

Get a Quick Quote for a Eaton MD63E92ZZ

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MD63E92ZZ? Enquire Now

FAQs

When installing the MD63E92ZZ, ensure adequate ventilation around the open-core assembly to maximize cooling. Provide proper clearance for service access, mount on a rigid frame, and follow UL Recognized safety guidelines. Check that the DT-3 designation and 914S frame fit your enclosure and panel spacing. Plan for the +5% and -5% tap adjustments to accommodate minor supply fluctuations.
Key specs include a 63 kVA rating, 60 Hz, three-phase configuration, 460 V primary, and 460Y/266 V secondary. Taps at +5% FCAN and -5% FCBN allow on-site voltage compensation to maintain output within tolerance during input variation, reducing the need for additional regulation equipment and improving system reliability.
Yes. The MD63E92ZZ is designed as a drive isolation transformer with a dry-type, open-core configuration. Its DT-3 design provides effective isolation between primary and secondary windings, mitigating transients and protecting sensitive drives in motor control centers and power distribution panels.
This unit carries UL Recognized certification, which supports safety compliance and approval processes in many regions. Open-core and coil assembly is noted in catalog information, aiding audits and supplier qualification. Always verify local compliance requirements for your installation and file the UL Recognized mark accordingly.
Maintenance is typical for dry-type transformers: periodic visual inspections, thermal checks, and insulation verification. The aluminum windings and robust 150 °C rise rating contribute to durable operation under higher ambient temps, reducing unplanned downtime. The 63 kVA rating and flexible taps support scalable loads, improving overall ROI through asset longevity and minimized spare-part diversification.