Eaton MD660E93 Drive Isolation Transformer - UL Listed

Part Number: MD660E93
Manufacturer
Eaton
Part number
MD660E93

Quick Summary

Drive isolation transformer MD660E93 from Eaton delivers reliable, high-capacity power conditioning for motor drives in industrial facilities. In practice, voltage dips, startup surges, and EMI can derail production and shorten asset life, especially in high‑demand automation lines. UL Listed safety certification underscores compliance with recognized standards, while the DT-3 dry-type design supports rugged factory environments with ventilated cooling. For buyers and engineers, this transformer translates to predictable performance, scalable 660 kVA capacity, and compatibility with 460 V input and 575Y/332 V outputs across varied panel architectures. Its aluminum windings and ventilated construction help manage heat during continuous operation, reducing the risk of thermal faults and extending service life.

Product Information

Extended Description

MD660E93 Eaton: Eaton 660 kVA Rating; 3-Phase; DT-3 Drive Isolation Transformer; Ventilated; 460; 575Y/332; 150 Degree C; Aluminum Windings
Product Name
Eaton Motor drive isolation ventilated transformer
Catalog Number
MD660E93
UPC
786680337505
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
DT-3
Tap size
1 at +5% FCAN, 1 at -5% FCBN
Type
Dry Type Distribution, Drive Isolation Transformer
Frequency rating
60 Hz
Kva Rating
660 kVA
Phase
Three-phase
Primary voltage
460 V
Secondary Voltage
575Y/332 V
Temperature rise
150 °C rise
Feature: 660 kVA three-phase rating with 460 V input and 575Y/332 V secondary drives robust motor control and startup resilience. Business Impact: Provides ample headroom to absorb transient loads and harmonics, enabling fewer upsizing decisions and lower total cost of ownership. Application: ideal for central power conditioning in motor control centers across manufacturing lines and automation suites. Feature: Dry-type ventilated construction with aluminum windings enhances cooling efficiency and longevity. Business Impact: reduces cooling losses, supports reliable performance in hot plants, and lowers maintenance frequency. Application: suitable for on-board panel installations and spaces with natural ventilation. Feature: DT-3 design with precise tap settings at +5% FCAN and -5% FCBN improves voltage matching to bus voltages. Business Impact: minimizes voltage misalignment, reduces derating, and speeds integration with existing drives. Application: common in retrofit and new build projects for drive isolation. Feature: UL Listed certification confirms compliance with safety standards. Business Impact: simplifies procurement, audits, and regulatory approvals. Application: preferred for regulated industries and OEM integrations demanding certified components. Feature: 150 °C temperature rise rating supports higher operating margins under peak loads. Business Impact: lowers risk of thermal faults, supports continuous operation, and improves uptime. Application: effective in environments with elevated ambient temperatures and demanding drive cycles.

Get a Quick Quote for a Eaton MD660E93

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MD660E93? Enquire Now

FAQs

The MD660E93 is a 660 kVA dry-type, three-phase transformer with a 460 V to 575Y/332 V configuration. Plan for adequate ventilation, proper clearance for heat dissipation, and accessible maintenance access. Verify correct phase rotation, secure mounting, and configure taps at +5% and -5% FCAN/FCBN to match bus voltage during commissioning.
By delivering true drive isolation, the MD660E93 reduces voltage transients and EMI that can cause motor trips and drive faults. Its 150 °C rise rating and aluminum windings support reliable operation under demanding loads, while the ventilated design keeps temperatures in check. This translates to fewer unplanned outages and more predictable automation performance.
Yes, the MD660E93 can be integrated where 460 V input and 575Y/332 V secondary outputs are compatible with existing motor drives. Its DT-3 dry-type design and positive tap options help accommodate voltage variations. Ensure panel space, cooling, and clearance meet installation requirements, and verify coordination with existing protection and control schemes.
The MD660E93 carries UL Listed certification, confirming safety standard compliance for industrial transformer installations. This simplifies audits and regulatory approvals in manufacturing environments. The design also supports standard industry practices for dry-type drive isolation transformers used in motor control centers.
Maintenance is typically minimal due to the dry-type, ventilated construction and aluminum windings. The 660 kVA rating enables consolidation of multiple smaller units, reducing footprint and installation costs. Improved reliability and reduced downtime contribute to a favorable return on investment, particularly in high-demand automation lines.