Eaton MD770E88 Motor drive isolation transformer - UL Listed

Part Number: MD770E88
Manufacturer
Eaton
Part number
MD770E88

Quick Summary

MD770E88 motor drive isolation ventilated transformer provides clean, isolated power for three-phase drive systems in industrial facilities. Engineers often confront electrical noise, transients, and downtime that disrupt sensitive motor drives. UL Listed certification ensures safety and reliability across harsh installations. This unit employs a DT-3 dry-type design with aluminum windings and a ventilated enclosure, delivering robust performance in hot or crowded electrical rooms. By combining precise voltage regulation with strong thermal management, it supports reliable drive operation while simplifying compliance and maintenance. For integrators, the transformer pairs readily with 60 Hz networks and 230 V sources, offering a scalable solution that reduces ripple and protects critical motors and drives in production lines.

Product Information

Extended Description

MD770E88 Eaton: Eaton 770 kVA Rating; 3-Phase; DT-3 Drive Isolation Transformer; Ventilated; 230; 230Y/133; 150 Degree C; Aluminum Windings
Product Name
Eaton Motor drive isolation ventilated transformer
Catalog Number
MD770E88
UPC
786680337055
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
DT-3
Tap size
1 at +5% FCAN, 1 at -5% FCBN
Type
Dry Type Distribution, Drive Isolation Transformer
Frequency rating
60 Hz
Kva Rating
770 kVA
Phase
Three-phase
Primary voltage
230 V
Secondary Voltage
230Y/133 V
Temperature rise
150 °C rise
DT-3 dry-type design with drive isolation reduces electrical noise and transient energy from the power source reaching motor drives, boosting equipment life and reducing nuisance tripping. This isolation improves EMI performance, minimizes voltage spikes at soft starts, and helps protect sensitive sensors in automation cells. For systems like CNC machines and packaging lines, this translates to fewer unplanned stops and more consistent cycle times. It also reduces harmonics emitted by VFDs, contributing to a cleaner electrical environment. The MD770E88 delivers a robust 770 kVA rating in a three-phase, 60 Hz configuration, supporting high-duty drives and distributing power to multiple motors without overheating. The primary 230 V and secondary 230Y/133 V outputs align with common plant electrical architectures, simplifying panel layouts and reducing panel space. This combination enables plug-in integration with existing Eaton or third-party drive systems and minimizes field rewiring, start-up time, and test iterations. Ventilated construction coupled with aluminum windings provides efficient cooling and corrosion resistance in harsh electrical rooms. The 150 °C rise rating gives a healthy thermal margin during peak demand or in warm environments, helping maintain voltage regulation under heavy load. The design also supports easy service access, reducing mean time to repair and downtime during maintenance windows. In environments with dust, humidity, or coastal climates, aluminum windings contribute to longer life and predictable performance. Voltage taps at +5% FCAN and -5% FCBN offer precise voltage regulation to compensate line fluctuations and voltage drops, reducing the need for external regulators and improving drive stability. Engineers can tune the transformer to match site conditions, accelerating commissioning and delivering a stable downstream voltage for motors and drives. The compact footprint and simple wiring scheme further streamline installation in retrofit projects. UL Listed certification confirms safety compliance for industrial installations, and Eaton’s warranty policy adds post-installation support and coverage. The combination of DT-3 drive isolation, rugged cooling, and clear technical documentation aligns with industry best practices for reliable, maintainable drive power systems and long service life. With Eaton as the OEM, customers gain access to verified datasheets and service networks that minimize risk.

Get a Quick Quote for a Eaton MD770E88

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MD770E88? Enquire Now

FAQs

For MD770E88 installations, ensure adequate ventilation and clearance around the unit due to its ventilated dry-type construction. Mounting should follow manufacturer guidelines to maintain cooling efficiency, with a 230 V primary supply and 230Y/133 V secondary readiness. Plan for the DT-3 design’s access for taps (+5% and -5%) and schedule maintenance to minimize downtime in busy production areas.
The transformer isolates drives from supply transients and reduces EMI, protecting sensitive motor control electronics. With a 770 kVA rating and 60 Hz operation, it supports large drives and multiple motors, while aluminum windings and ventilation maintain stable temperatures. The result is fewer trips, smoother starts, and extended drive life in demanding manufacturing environments.
Yes. The MD770E88 is designed as a drive isolation transformer with 230 V primary and 230Y/133 V secondary outputs, suitable for integration with Eaton and third‑party motor drive systems operating at 60 Hz. Its DT-3 dry-type construction and ventilated design ease installation in common control panels and electrical rooms.
The MD770E88 carries UL Listed certification, ensuring compliance with recognized safety standards for industrial electrical equipment. This certification supports safer installation in manufacturing facilities and aligns with common procurement requirements for electrical components used in drive isolation and power distribution.
Investing in the MD770E88 can reduce downtime through improved drive uptime, reduced transients, and better motor protection. Its robust cooling (150 °C rise), durable aluminum windings, and straightforward tap adjustments simplify maintenance and commissioning. Over time, these factors translate to lower maintenance costs, fewer unplanned outages, and extended motor and drive service life.