Eaton MD93E86CU Motor drive isolation ventilated transformer - UL Listed

Part Number: MD93E86CU
Manufacturer
Eaton
Part number
MD93E86CU

Quick Summary

MD93E86CU motor drive isolation ventilated transformer delivers clean, isolated power for three-phase motor drives in industrial automation. Engineers often grapple with voltage fluctuations, electrical noise, and thermal stress that shorten drive life. UL Listed safety certification with the DT-3 dry-type design supports compliance in typical industrial environments, while the ventilated cooling and 93 kVA rating enable reliable power conditioning for demanding drive applications. The unit’s compact footprint and WS19 weather shield compatibility help streamline procurement and installation in existing plant spaces, delivering measurable business value through reduced downtime, improved power quality, and easier maintenance for motor control systems. This product is a robust fit for dry-type transformer needs, drive isolation, and high-load motor drives in manufacturing and processing facilities.

Product Information

Extended Description

MD93E86CU Eaton: Drive Isolation Transformer, Ventilated, Dry Type Distribution, DT-3, Three-phase, PV: 208V, Taps: 1 at +5% FCAN, 1 at -5% FCBN, SV: 460Y/266V, 150°C, 93 kVA, Cu windings, Frame: 916A, uses WS19
Product Name
Eaton Motor drive isolation ventilated transformer
Catalog Number
MD93E86CU
UPC
786680051623
Product Length/Depth
23.42 in
Product Height
48.56 in
Product Width
28.22 in
Product Weight
426.6 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Copper
Design
DT-3
Frame
916A
Tap size
1 at +5% FCAN, 1 at -5% FCBN
Type
Dry Type Distribution, Drive Isolation Transformer
Frequency rating
60 Hz
Phase
Three-phase
Primary voltage
208 V
Secondary Voltage
460Y/266 V
Temperature rise
150 °C rise
Volt ampere rating
93 kVA
Weathershield
WS19
Dry-type, ventilated DT-3 design provides safe, maintenance-friendly cooling with no oil, reducing fire risk and enabling indoor or semi-outdoor installations. This translates to lower lifecycle costs and easier compliance for industrial control rooms across manufacturing facilities. The three-phase, 60 Hz configuration with a 208 V primary and 460Y/266 V secondary delivers consistent drive voltage, minimizing nuisance tripping and extending inverter life in variable plant conditions. Copper windings offer high efficiency and reduced copper losses, supporting reliable operation under peak motor loads and enabling slimmer energy footprints for motor drive systems. The 93 kVA rating accommodates significant drive power while maintaining compact form factors, and the taps at +5% and -5% provide voltage flexibility to match plant supply variations without additional equipment. With a frame of 916A and a footprint derived from 23.42 in depth, 28.22 in width, and 48.56 in height, installation is predictable within standard switchgear or control panels. WS19 Weathershield protection extends outdoor or harsh-environment viability, reducing enclosure requirements and rework. UL Listed certification adds confidence for compliance teams and procurement, ensuring the solution meets essential electrical safety standards for industrial equipment. From a technician’s perspective, the modular design and clear labeling ease commissioning and future scalability, supporting long-term ROI through reduced maintenance time and predictable performance in dynamic production lines.

Get a Quick Quote for a Eaton MD93E86CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MD93E86CU? Enquire Now

FAQs

The transformer fits standard footprints with a 23.42 in depth, 28.22 in width, and 48.56 in height, weighing about 426.6 lb. Ensure ventilation or WS19 protection where outdoor exposure exists, allow clearance for ventilation, and mount on a compatible frame such as 916A. Provide 208 V input at three-phase supply and plan for the 460Y/266 V secondary to feed associated motor drives or VFDs.
With 93 kVA capacity and copper windings, the unit offers efficient power conditioning and robust drive isolation at 60 Hz. The DT-3 dry-type design minimizes oil-related risks, while the +5% and -5% taps help maintain voltage stability under supply variations, reducing motor stress and nuisance trips in varying plant conditions.
Yes. The transformer uses WS19 weather shield protection and a dry-type insulation system, enabling safer operation in challenging environments. It is UL Listed, providing recognized safety compliance for industrial power equipment.
Primary voltage is 208 V, with a secondary of 460Y/266 V. It includes taps at +5% FCAN and -5% FCBN to accommodate plant voltage fluctuations, supporting stable drive performance without external regulation equipment.
The product is covered by Eaton’s standard warranty policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first, providing critical protection during initial commissioning and early operation.