Eaton MDL3600 Molded Case Circuit Breaker - UL Listed
Part Number: MDL3600
Quick Summary
Eaton Series C molded case circuit breaker MDL3600 provides reliable overcurrent protection for industrial electrical distribution and control panels. This compact, three-pole MCCB helps prevent equipment damage and costly downtime by delivering precise fixed thermal and magnetic trip protection. End users often struggle with nuisance trips, wiring complexity, and panel downtime; MDL3600 simplifies protection with a standardized MDL frame and robust trip characteristics. UL Listed certification underscores safety and compliance for North American installations, while the Series C documentation supports consistent performance across your portfolio. With a 600 A rating and 50/60 Hz compatibility, this device fits mainstream industrial applications and pairs well with Eaton accessories for easier installation and service.
Product Information
Extended Description
MDL3600 Eaton: Eaton Series C complete molded case circuit breaker, MDL-frame, MDL, Complete breaker, Fixed thermal, Fixed magnetic trip type, Three-pole, 600 A, 600 Vac, 250 Vdc, 65 kAIC at 240 Vac, 50 kAIC at 480 Vac, 50/60 Hz
Product Name
Eaton Series C complete molded case circuit breaker
Catalog Number
MDL3600
UPC
782114585986
Product Length/Depth
10.75 in
Product Height
10.75 in
Product Width
10.75 in
Product Weight
30 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Amperage Rating
600 A
Voltage rating
600 Vac, 250 Vdc
Trip Type
T186
Circuit breaker type
MDL
Circuit breaker frame type
Complete breaker
Series
Series C
Frame
MDL
Frequency rating
50 to 60 Hz
Interrupt rating
50 kAIC at 480 Vac 65 kAIC at 240 Vac
Number of poles
Three-pole
Application of Tap Rules to Molded Case Breaker Terminals
Application of Tap Rules to Molded Case Breaker Terminals
Application of Tap Rules to Molded Case Breaker Terminals
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Breaker service centers
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
Circuit breakers explained
Circuit breakers explained
Series C F-Frame molded case circuit breakers
Series C F-Frame molded case circuit breakers
Series C F-Frame molded case circuit breakers
Series C F-Frame molded case circuit breakers
Series C F-Frame molded case circuit breakers
Feature 1: 600 A amperage rating with a 600 Vac / 250 Vdc voltage rating. Business impact: Enables reliable protection for high-load panels and motor feeders while maintaining coordination with downstream devices. Application: Suitable for electrical distribution and machine control panels where robust overcurrent protection is required. Long-tail keywords embedded: molded case circuit breaker 600 A, Series C MCCB, three-pole protection. Feature 2: Fixed thermal and fixed magnetic trip (T186). Business impact: Delivers predictable tripping behavior, reducing nuisance trips and enabling selective coordination. Application: Critical for panels with diverse loads and motor start-up sequences. Feature 3: Three-pole MDL frame, Series C, 50 to 60 Hz. Business impact: Ensures compatibility across global systems and simplifies stocking for multinational facilities. Application: Standardized protection in panelboards and MCC locations. Feature 4: Interrupt rating up to 65 kAIC at 240 Vac and 50 kAIC at 480 Vac. Business impact: Supports protection of high-energy equipment with strong fault current containment. Application: Industrial environments with high fault current potential. Feature 5: Compact dimensions (10.75 in per side) and 30 lb weight. Business impact: Facilitates easier installation, panel filling, and service access, lowering labor costs. Application: Retrofit projects and new installations where space is at a premium. Feature 6: UL Listed certification and Eaton warranty. Business impact: Provides regulatory assurance and post-sale support, improving total cost of ownership. Application: Compliance-driven deployments in North American facilities and service contracts with Eaton support.
Get a Quick Quote for a Eaton MDL3600
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MDL3600?
Enquire Now
FAQs
Install MDL3600 in standard Series C panel enclosures with adequate clearance for 10.75 in dimensions per side and proper bussing. Ensure alignment with three-pole configurations and use compatible MDL frame accessories to simplify wiring and terminations.
Amperage rating: 600 A; Voltage rating: 600 Vac / 250 Vdc; Trip type: T186; Poles: Three-pole; Frame: MDL; Frequency: 50–60 Hz; Interrupt rating: 50 kAIC at 480 Vac and 65 kAIC at 240 Vac.
Yes. The fixed thermal/magnetic trip type and three-pole design make it suitable for motor feeders and motor control centers, providing reliable protection against overloads and short circuits while supporting safe startup sequences.
The MDL3600 is UL Listed, ensuring compliance with key North American safety standards for molded case circuit breakers.
Dimensions are 10.75 in height, width, and depth; weight is 30 lb, aiding mounting planning, clearance, and manpower estimates during installation or retrofit.