Eaton MIS-1 Fuse - 200 kAIC at 600 Vac CE Marked

Part Number: MIS-1
Manufacturer
Eaton
Part number
MIS-1

Quick Summary

The Eaton MIS-1 fuse is a 1 A non-time-delay protective device designed for 480 V control circuits and PLC applications. Operators and engineers often struggle with unclear fuse status and the risk of nuisance trips in high-demand automation lines. The device is CE marked and rated for 600 V systems with a 200 kAIC interrupt rating, ensuring reliable protection in critical panels. Designed for straightforward installation and robust ferrule-end terminations, MIS-1 helps reduce downtime and support scalable control architectures. Its standard footprint and non-indicating status keep initial costs predictable while enabling safer maintenance workflows.

Product Information

Extended Description

MIS-1 Eaton: Eaton Bussmann series MIS fuse, Non time-delay fuse, 480 V Control circuits, PLC circuits, 1 A, Non-indicating, Ferrule end x ferrule end, 200 kAIC at 600 Vac, Standard, 600 V
Product Name
Eaton Bussmann series MIS fuse
Catalog Number
MIS-1
UPC
051712624060
EAN
5027590400503
Product Length/Depth
0.46 in
Product Height
2.25 in
Product Width
0.46 in
Product Weight
0.3 lb
Warranty
Not Applicable
Compliances
CE Marked
Amperage Rating
1 A
Interrupt rating
200 kAIC at 600 Vac
Voltage rating
600 V
Packaging type
Standard
Connection
Ferrule end x ferrule end
Fuse indicator
Non-indicating
The 1 A amperage rating provides precise fault isolation in small control loops, minimizing unnecessary power interruption and improving PLC uptime. In practice, this means faster reset times after a fault and reduced collateral damage to adjacent devices, especially in densely wired machine cabinets where overprotection can trigger unintended trips. This is ideal for control panels housing logic modules and small actuators in automated lines. The 200 kAIC interrupt rating at 600 Vac delivers a robust defense against high-energy faults common in industrial environments, lowering arc-flash risk and supporting safe maintenance even when feeders or motors create large fault currents. Engineers can deploy MIS-1 with confidence in power-dense panels and uplinked PLC cages. Ferrule-end connections provide a reliable, vibration-resistant termination that simplifies field wiring and reduces termination time during panel dress tasks, improving installation efficiency and long-term reliability. Non-indicating status keeps the device compact and cost-effective, while standard packaging supports streamlined procurement and stocking across multiple sites. The CE Marked compliance ensures global applicability in regulated environments and aligns with common 600 V control system voltages, enabling faster procurement and consistent performance across international projects.

Get a Quick Quote for a Eaton MIS-1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MIS-1? Enquire Now

FAQs

MIS-1 uses ferrule-end terminations for robust, vibration‑resistant connections and a compact 0.46 in by 0.46 in cross-section with a 2.25 in height. Ensure panel cutouts accommodate the ferrule ends and verify that wiring harnesses provide appropriate ferrule sizes. The device aligns with standard Bussmann series footprints, simplifying field replacement and spares management.
MIS-1 is rated for 1 A with a 200 kAIC interrupt rating at 600 V. The fuse is designed for 600 V control circuits and PLC applications, providing high fault-current withstand in demanding industrial environments while protecting sensitive logic devices and 480 V feeders.
Yes. MIS-1 is specifically intended for PLC and 480 V control circuit protection. Its 1 A rating and 200 kAIC interrupt capability provide precise protection for control panels without unnecessary downtime, while its ferrule-end construction ensures reliable terminations in automation cabinets and machine control environments.
MIS-1 carries CE marking, indicating compliance with applicable European health, safety, and environmental requirements. This certification supports global deployment in regulated facilities and aligns with common 600 V control system standards found in industrial automation.
MIS-1’s non-indicating design reduces component costs and simplifies physical footprint in crowded panels, lowering initial procurement and stocking costs. The high 200 kAIC interrupt rating minimizes the risk of costly fault events and associated downtime, delivering measurable return on investment through improved system reliability and shorter maintenance windows in automated production environments.