Eaton MPS8403HEAXX2F Magnum LV Circuit Breaker - UL Listed
Part Number: MPS8403HEAXX2F
Quick Summary
Eaton MPS8403HEAXX2F is a Magnum LV circuit breaker for industrial control panels. Engineers struggle with miscoordination and nuisance trips; this unit’s PXR20 LSIGAM trip and high interrupting capacity address that. CE Marked, UL Listed, and CSA Certified ensure global compliance and safe operation across equipment. In addition, its fixed horizontal mounting and three-pole design support quick installation and robust protection with Power Xpert readiness for digital protection management.
Product Information
Extended Description
MPS8403HEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (ABCABC), 85 kA, Three-pole, Fixed horizontal mounting, PXR20 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8403HEAXX2F
UPC
786689628376
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked SABA Listed CCC Marked NEMA Compliant
Certifications
CSA Certified UL Listed KEMA Certified Lloyd's Register Certified ANSI ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8403HEAXX2F
Eaton Specification Sheet - MPS8403HEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Feature: Three-pole design and fixed horizontal mounting; Business Impact: simplifies cabinet integration and improves protection coordination; Application: panelboards and motor control centers. Feature: Icu of 85 kA and a 4000 A frame; Business Impact: withstands high fault currents and supports large-scale installations; Application: process facilities and mining environments. Feature: PXR20 LSIGAM trip unit; Business Impact: enables advanced protection logic, event capture, and seamless compatibility with Power Xpert Protection Manager; Application: MCCs and critical process loads. Feature: Certifications and regulatory compliance; Business Impact: reduces procurement risk and streamlines global deployments; Application: any region requiring CE UL CSA compliance. Feature: Comprehensive documentation and training resources; Business Impact: shortens design and commissioning time; Application: engineering teams and maintenance planning.
Get a Quick Quote for a Eaton MPS8403HEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8403HEAXX2F?
Enquire Now
FAQs
The MPS8403HEAXX2F uses fixed horizontal mounting and is a three-pole device with dimensions suited for panel integration. With a length/depth of 16.3 in, height of 16.8 in, and width of 31.1 in, install in standard electrical enclosures or MCCs while aligning with bus bars and ensuring proper clearance for cooling and wiring. The PXR20 LSIGAM trip unit simplifies wiring and integration with protection management systems.
This breaker belongs to the Magnum PXR family with a 4000 A frame and an 85 kA short-circuit interrupting capacity (Icu). It is a three-pole device equipped with the PXR20 LSIGAM trip unit, enabling advanced protection logic and coordination for demanding industrial applications such as motors and process loads.
The MPS8403HEAXX2F is CE Marked and UL Listed, with CSA Certification also noted in its specifications. These certifications ensure global regulatory compliance, safety conformity, and acceptance across major markets, reducing sourcing risk and facilitating international projects in panels, MCCs, and control cabinets.
Yes. The breaker uses the PXR20 trip unit from the Magnum PXR family, designed for compatibility with Eaton Power Xpert Protection Manager. Configuration relates to protection schemes, metering, and event logging via compatible software tools. Resources such as the quick start guide and Protection Manager installers are available in the downloads section to accelerate setup.
Ideal for panelboards and motor control centers in high-demand environments, it delivers robust fault protection (85 kA Icu), reliable coordination (PXR20), and global certifications (UL/CE/CSA). The result is reduced nuisance trips, faster fault isolation, easier compliance, and lower total cost of ownership through improved uptime and predictive maintenance readiness.