Eaton MPS8404HEAXX2H Magnum low voltage circuit breaker - UL Listed
Part Number: MPS8404HEAXX2H
Quick Summary
Eaton Magnum low voltage power circuit breaker protects critical power feeds in industrial automation applications. If you’re wrestling with nuisance trips, poor selectivity, or costly downtime, this device helps you tighten protection without sacrificing reliability. UL Listed, CE Marked, and CSA Certified certifications ensure global compliance, while Zone Selective Interlocking (ZSI) and the Power Xpert Release PXr20 trip unit support coordinated protection across motor feeders and distribution panels. The Magnum design—fixed horizontal mounting with a PXR20 LSIAM trip unit—facilitates fast installation in MCCs and control panels. By aligning with Protection Manager workflows, you gain easier monitoring and faster fault isolation, reducing maintenance costs and unplanned outages.
Product Information
Extended Description
MPS8404HEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NNABCABC), 85 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8404HEAXX2H
UPC
786689628468
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked NEMA Compliant CE Marked SABA Listed
Certifications
CSA Certified UL Listed Lloyd's Register Certified KEMA Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8404HEAXX2H
Eaton Specification Sheet - MPS8404HEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
High current handling and fault protection: The MPS8404HEAXX2H delivers a 4000 A frame and 85 kA interrupt rating, providing rapid, reliable interruption for dense power circuits. This reduces equipment damage and enables safer operation during short-circuit events, especially in motor control centers and distribution panels where fault currents are high. The four-pole design ensures balanced protection across phases, simplifying wiring and improving reliability in large panel assemblies. Fixed horizontal mounting accelerates installation and minimizes misalignment, which translates to lower commissioning time and fewer field errors. Compact, rugged construction is compatible with standard MCC racks, enabling straightforward retrofits or new builds without custom enclosures. These characteristics support long-term uptime and predictable maintenance cycles.
Get a Quick Quote for a Eaton MPS8404HEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8404HEAXX2H?
Enquire Now
FAQs
The MPS8404HEAXX2H uses a fixed horizontal mounting suitable for motor control centers and switchgear assemblies. Its four-pole design supports balanced three-phase protection, and the 16.3 in depth, 16.8 in height, and 44.1 in width help determine enclosure fit. Always verify available panel width and mounting rails to ensure proper alignment and secure installation.
Key specs include a 4000 A frame rating and an 85 kA interrupting capacity, four-pole configuration, and a Power Xpert Release PXr20 LSIAM trip unit option. It is UL Listed and CE Marked, with additional certifications, enabling reliable performance in demanding industrial environments and supporting compliance across regions.
Yes, the product supports zone selective interlocking (ZSI) concepts, aided by the PXr release trip unit and Eaton’s protection tooling. ZSI enables faster fault isolation and reduced arc energy. For best results, refer to Eaton’s interlocking papers and ensure proper wiring and coordination with downstream protection devices.
This model carries UL Listed, CE Marked, and CSA Certified labels, along with several other certifications (Lloyd's Register, KEMA, ANSI, DNV GL, ABS). These certifications support global deployment, passing audits, and compliance across industries such as manufacturing, oil & gas, and data centers.
Using Magnum PXR with Power Xpert Protection Manager centralizes protection settings, enabling faster fault diagnosis and reduced downtime. The combination supports predictive maintenance, easier firmware updates, and coordinated protection across devices, which lowers long-term operating costs and extends equipment life while simplifying asset management and reporting.