Eaton Magnum LV Circuit Breaker MPS84N3HEAXX2H UL Listed
Part Number: MPS84N3HEAXX2H
Quick Summary
The Eaton Magnum LV Circuit Breaker is a reliable, three-pole protection device designed to guard industrial power distribution panels. It helps address downtime and reliability challenges by interrupting fault currents quickly and accurately. This unit carries UL Listed and CE Marked certifications, with ANSI and CSA attestations supporting global installations, and it supports a Power Xpert Release trip unit option for advanced coordination. With a double-frame Magnum design and fixed horizontal mounting, it simplifies retrofit projects, reduces wiring complexity, and enables easier service access. By delivering robust protection and simpler maintenance, this breaker adds business value through improved uptime and lower total cost of ownership for critical electrical systems.
Product Information
Extended Description
MPS84N3HEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (AABBCC), 85 kA, Three-pole, Fixed horizontal mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS84N3HEAXX2H
UPC
786689629342
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked SABA Listed NEMA Compliant CE Marked
Certifications
UL Listed CSA Certified KEMA Certified ANSI Lloyd's Register Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS84N3HEAXX2H
Eaton Specification Sheet - MPS84N3HEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Is a modular, three-pole low-voltage protection device designed to interrupt fault currents quickly in industrial power distribution. Key specifications include a 4000 A frame, 85 kA short-circuit rating, a PXR20 LSIAM trip unit, three-pole configuration, fixed horizontal mounting, and a footprint that measures 16.3 in length, 16.8 in height, and 31.1 in width. Primary applications span panel boards, motor control centers, and distribution panels in manufacturing, mining, and water treatment sectors. Core benefits include improved selectivity, reduced downtime, and easier field maintenance when paired with Power Xpert Protection Manager. This model carries UL Listed and CE Marked certifications, with ANSI and CSA attestations supporting global compliance. Its durable form factor supports straightforward retrofits and compatibility with zone selective interlocking when integrated with the product ecosystem.
Get a Quick Quote for a Eaton MPS84N3HEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS84N3HEAXX2H?
Enquire Now
FAQs
The MPS84N3HEAXX2H supports Power Xpert Protection Manager through its PXR20 LSIAM trip unit, enabling unified protection settings, real-time monitoring, and coordinated tripping across devices. This compatibility reduces engineering time, improves visibility into protection schemes, and helps achieve selective coordination in complex panels and motor control centers.
Key specs include a 4000 A frame, 85 kA short-circuit rating, 3-pole configuration, fixed horizontal mounting, and levered access to the PXR20 LSIAM trip unit. Ensure panel cavity dimensions accommodate 16.3 in length, 16.8 in height, and 31.1 in width, with a weight around 237 lb for mechanical clearance and mounting tolerance.
Plan for the fixed horizontal mounting footprint and the double-standard Magnum frame to optimize busbar and conductor routing. Use the 3-pole configuration to simplify protection schemes, ensure compatibility with existing zone selective interlocking documentation, and factor in the 237 lb unit weight for rack loading. The product’s dimensions aid precise enclosure planning and retrofit ease.
This model is UL Listed and CE Marked, with additional attestations including CSA Certified, KEMA Certified, ANSI, Lloyd’s Register Certification, ABS Certification, and DNV GL Certification. CCC Marked and SABA Listed compliance are noted in the product data, supporting global usage across industrial environments.
Benefiting from faster fault isolation, improved selectivity, and easier maintenance, the Magnum PXR-based protection reduces downtime and extends service intervals. When paired with Power Xpert Protection Manager, operators gain better visibility and coordination, reducing nuisance trips and enabling targeted, data-driven improvements to the power distribution network.