Eaton MPS84N3HEAXX2S Magnum LV Circuit Breaker - 85 kAIC

Manufacturer
Eaton
Part number
MPS84N3HEAXX2S

Quick Summary

Eaton Magnum low voltage power circuit breaker protects industrial power distribution panels from overloads and short circuits. In busy manufacturing environments, nuisance trips, limited protection coordination, and challenging integration with protection relays can drive downtime and escalate maintenance costs. UL Listed and CE Marked certifications—along with Lloyd's Register Certified status—underscore global reliability and safety, while KEMA and ANSI attest to rigorous performance standards. This model also supports Power Xpert Protection Manager integration and the Power Xpert Release trip unit family, enabling smarter protection coordination. Together, these features deliver business value by improving uptime, simplifying compliance, and enabling scalable protection strategies for modern control panels and motor circuits.

Product Information

Extended Description

MPS84N3HEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (AABBCC), 85 kA, Three-pole, Fixed horizontal mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS84N3HEAXX2S
UPC
786689629366
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
NEMA Compliant CCC Marked SABA Listed CE Marked
Certifications
Lloyd's Register Certified KEMA Certified UL Listed CSA Certified ANSI DNV GL Certified ABS Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Three-pole
Rated uninterrupted current (Iu)
4000 A
Interrupt rating
85 kAIC
Interrupt rating
85 kAIC
Rated uninterrupted current (Iu)
4000 A
The Magnum MPS84N3HEAXX2S uses a triple-pole Magnum PXR frame with a fixed horizontal mounting configuration in a double standard frame, delivering installation flexibility and panel-density optimization for industrial power distribution. This translates to faster panel assembly and easier field retrofits in motor control centers and switchgear, reducing commissioning time and on-site labor costs. Rated uninterrupted current (Iu) of 4000 A supports large feeders and high-load panels, enabling designers to consolidate protection without oversized devices, which improves protection coordination and reduces total cost of ownership in data centers and manufacturing lines. With an 85 kA interrupt rating, it withstands high fault currents to limit equipment damage and arc energy exposure, driving lower downtime and safer maintenance in critical facilities. The PXR25 LSIGAM arms enhance protection accuracy and selectivity, enabling improved arc-energy management and faster fault isolation, which lowers spare parts and maintenance overhead over the lifecycle. Certifications and compliance—UL Listed, CE Marked, and Lloyd's Register Certified—streamline regulatory approvals and customer acceptance in regulated industries, while a robust frame and three-pole design offer compatibility with a wide range of panels and bus configurations. The device is designed for compatibility with Power Xpert Protection Manager and Power Xpert Release trip units, aiding remote monitoring, configuration, and diagnostics, which reduces on-site service visits and supports proactive maintenance. In practice, engineers gain a scalable protection strategy suitable for modern control panels, motor drives, and large switchgear arrays, with measurable improvements in uptime, reliability, and safety.

Get a Quick Quote for a Eaton MPS84N3HEAXX2S

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS84N3HEAXX2S? Enquire Now

FAQs

Yes. The MPS84N3HEAXX2S is designed to work with Magnum PXR trip units, including the LSIGAM configuration, and it supports Power Xpert Protection Manager integration for centralized monitoring and control. When upgrading or retrofitting, verify the panel accepts a three-pole, fixed-horizontal mounting and double-standard frame to ensure proper fit and coordination with existing protection schemes.
Key specifications include a rated uninterrupted current (Iu) of 4000 A and an interrupt rating of 85 kAIC. It is a three-pole device with a Magnum PXR trip unit, designed for high-load panels and fault-current scenarios typical in large motor feeders and switchgear assemblies.
This breaker is well suited for industrial power distribution panels, motor control centers, data centers, and large electrical installations where high fault current management, reliable protection coordination, and compatibility with Power Xpert tools are critical for uptime and safety.
The device is UL Listed and CE Marked, with Lloyd's Register Certified and other recognized certifications such as KEMA and ANSI listed in the supporting documentation. These certifications support global compliance, regulatory approvals, and customer confidence in safety and performance.
By enabling higher current handling with 4000 A Iu, strong 85 kAIC fault withstand, and seamless Power Xpert integration, this breaker reduces unplanned downtime and maintenance visits. The availability of renewal parts, extensive documentation, and compatibility with protection management tools further lowers lifecycle costs through better diagnostics and proactive maintenance.