Eaton MPS84N4HEAXX2C Magnum low voltage power breaker - UL

Manufacturer
Eaton
Part number
MPS84N4HEAXX2C

Quick Summary

Eaton Magnum low voltage power circuit breaker MPS84N4HEAXX2C protects distribution panels in industrial facilities. When downtime, nuisance trips, or arc-flash risk threaten production, reliable protection and fast, coordinated tripping matter for uptime. UL Listed, CSA Certified, and CE Marked provide global installation confidence, with NEMA compliance reinforcing suitability for rugged environments. This solution leverages Power Xpert Release (PXR20 LSIG) for precise protection coordination, while remaining compatible with Magnum family tools and renewal options, delivering safer operations and easier maintenance for modern automation facilities.

Product Information

Extended Description

MPS84N4HEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NNAABBCC), 85 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS84N4HEAXX2C
UPC
786689629205
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked NEMA Compliant CE Marked SABA Listed
Certifications
KEMA Certified CSA Certified UL Listed Lloyd's Register Certified ANSI ABS Certified DNV GL Certified
Four-pole, fixed horizontal mounting simplifies panel integration and balance of protection across busbars, enabling compact layouts and faster install times. Feature leads to a measurable business impact: streamlined assemblies, reduced commissioning labor, and consistent protection for critical loads in factory lines or data center rooms. Applications include motor control centers and distribution panels where reliable interruption of fault current is essential. The 85 kA breaking capacity provides robust fault handling, reducing collateral damage and maintenance costs during high-energy faults. In practice, this translates to longer equipment life and lower total cost of ownership for heavy-industry environments. The 4000 A current rating supports large feeder protection with minimal nuisance tripping under transient events, improving process stability and operator confidence. Compatibility with PXR20 LSIG trip units enables selective coordination with Power Xpert Protection Manager for centralized monitoring and upgrades. This reduces risk during panel expansions and enables future-proofing of electrical infrastructure. The unit’s weight and dimensions (16.3 in depth, 16.8 in height, 44.1 in width, 319 lb) inform cabinet space planning and lifting requirements, avoiding last-minute installation delays. Certifications including UL Listed, CSA Certified, and CE Marked provide worldwide compliance, while CCC Mark and NEMA compliance support installation in diverse markets. The product supports zone selective interlocking and other safety-enhancing practices described in Eaton’s application notes, helping engineers align with industry best practices and safer-by-design principles.

Get a Quick Quote for a Eaton MPS84N4HEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS84N4HEAXX2C? Enquire Now

FAQs

The MPS84N4HEAXX2C uses fixed horizontal mounting with a four-pole configuration. This setup simplifies integration into distribution panels, ensures stable bus alignment, and enables compact layouts in switchgear enclosures. It also supports straightforward wiring access and reliable fault clearance in space-constrained industrial panels.
Yes. The 85 kA short-circuit breaking capacity provides robust protection for feeders and major loads in facilities with elevated fault currents. Combined with the 4000 A frame size, this enables dependable interruption of high-energy faults, minimizing damage to downstream equipment and reducing downtime after faults.
This breaker uses the Power Xpert Release (PXR20 LSIG) trip unit, offering advanced protection coordination. It is compatible with Power Xpert Protection Manager for centralized monitoring and upgrades, enabling scalable protection schemes and easier maintenance across multiple devices in the same plant.
This model is UL Listed, CSA Certified, and CE Marked, with additional compliance to NEMA requirements. It also aligns with CCC Marked and SABA Listed expectations, supporting global installation and adherence to multiple regulatory regimes across regions and industries.
Dimensions are 16.3 in depth, 16.8 in height, and 44.1 in width, with a weight of 319 lb. Plan for adequate cabinet space, lifting equipment for installation, and proper mounting clearances. Confirm panel cutouts and rack space in advance to ensure a smooth, on-time installation and safe operation.