Eaton Magnum low voltage power circuit breaker protects sensitive electrical loads in industrial power systems. Customers often struggle with nuisance tripping, poor coordination, and unplanned downtime when protection devices aren’t sized for system demand. This unit carries UL Listed, CE Marked, and ANSI/KEMA certifications, with Lloyd’s Register support for global compliance and reliability benchmarking. Designed for compatibility with Magnum PXR trip units and Power Xpert Protection Manager, it enables precise coordination, faster fault isolation, and data-driven maintenance—reducing downtime and boosting plant availability. The combination of high interrupting capacity and standardized mounting supports scalable protection across growing facilities while keeping lifecycle costs predictable.
Product Information
Extended Description
MPS84N4HEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NNAABBCC), 85 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS84N4HEAXX2H
UPC
786689629656
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
Lloyd's Register Certified ANSI KEMA Certified UL Listed CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x32 22.06 1
Power Xpert Protection Manager x32 22.06 1
Eaton Specification Sheet - MPS84N4HEAXX2H
Eaton Specification Sheet - MPS84N4HEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Feature: High current rating and fault capacity with a four-pole, fixed horizontal mounting frame. Business Impact: Enables protection of large feeders and motors with robust short-circuit withstand, reducing the risk of cascading outages and enabling safer, more reliable commissioning. Application: Large industrial panels, distribution boards, and motor starter enclosures. Feature: PXR20 LSIAM trip unit compatibility. Business Impact: Delivers selective coordination and advanced fault sensing, supporting faster fault isolation and reduced energy release during faults. Application: Complex manufacturing lines and critical process areas where downtime is costly. Feature: Magnum double standard frame with 4000 A capacity and 85 kA interrupting rating. Business Impact: Supports scalable protection for growing facilities, lowering future retrofit costs and simplifying expandability. Application: High-demand industrial installations and substations in manufacturing and infrastructure. Feature: Four-pole, fixed horizontal mounting design. Business Impact: Simplifies installation in existing enclosures and improves mechanical stability, reducing installation time and commissioning risk. Application: OEM assemblies, control panels, and service entrances. Feature: Global certifications including UL Listed, CE Marked, ANSI/KEMA, and Lloyd’s Register. Business Impact: Ensures compliance across markets, simplifying procurement and regulatory clearance. Application: Multinational plants with cross-border installation needs. Feature: Availability of application notes, performance datasheets, and protection-management software. Business Impact: Supports proactive maintenance, informed upgrades, and better lifecycle planning. Application: Reliability programs, asset management, and predictive maintenance initiatives.
Get a Quick Quote for a Eaton MPS84N4HEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS84N4HEAXX2H?
Enquire Now
FAQs
The MPS84N4HEAXX2H uses a fixed horizontal mounting design with a four-pole configuration and a double standard frame. Install in industrial panels or control enclosures with appropriate busbar access, ensuring adequate clearance for 16.3 in depth and 16.8 in height. Verify compatibility with existing Magnum PXR trip units and Power Xpert Protection Manager for optimal coordination and serviceability.
Key specs include a 4000 A frame current rating, an 85 kA short-circuit rating, four-pole construction, and a PXR20 LSIAM trip unit. The unit is designed for fixed horizontal mounting and multiple certifications, enabling reliable protection for high-demand feeders and motors in demanding industrial environments.
This breaker is UL Listed and CE marked, with ANSI/KEMA certification and Lloyd’s Register support. These certifications help ensure market access in North America and Europe, demonstrate safety and performance to regulatory bodies, and support risk management, procurement consistency, and cross-border project approvals.
Yes. The MPS84N4HEAXX2H is designed to work with Magnum PXR trip units and Power Xpert Protection Manager, enabling advanced coordination, event logging, and remote management. This supports selective protection schemes, faster fault isolation, and improved diagnostic capabilities, contributing to reduced downtime and easier compliance tracking.
Industries with large motor drives, process automation, data centers, and heavy manufacturing benefit from its high interrupting capacity, four-pole protection, and scalable coordination. The combination of UL CE certifications, robust protection, and integration with protection management tools supports lower maintenance costs, reduced downtime, and longer asset life in high-demand environments.