Eaton MPS8503HEAXX2H Magnum low voltage power circuit breaker - UL Listed

Part Number: MPS8503HEAXX2H
Manufacturer
Eaton
Part number
MPS8503HEAXX2H

Quick Summary

Eaton MPS8503HEAXX2H Magnum low voltage power circuit breaker is designed for demanding industrial power protection. Operators often struggle with nuisance trips, coordination gaps, and integration hurdles when upgrading legacy panelboards. This model carries UL Listed, KEMA Certified, and CE Marked certifications, with ANSI/CSA/Lloyd’s Register recognition for global compliance. With Power Xpert Release compatibility and the PXR20 LSIAM trip unit, it enables precise protection and scalable coordination across protection schemes. In practice, engineers gain faster fault isolation, easier integration with protection managers, and reduced lifecycle costs through fewer false trips.

Product Information

Extended Description

MPS8503HEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 85 kA, Three-pole, Fixed horizontal mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8503HEAXX2H
UPC
786689629540
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
KEMA Certified ANSI CSA Certified Lloyd's Register Certified UL Listed DNV GL Certified ABS Certified
Feature: High interrupting capacity and triple-pole Magnum frame. The MPS8503HEAXX2H offers 5000 A interrupting capability (ABCABC), 85 kA short-circuit rating, and a three-pole configuration in a double standard frame. Business impact: robust fault protection for large motors and feeders reduces equipment damage and unplanned downtime. Application: main distribution panels and machine control centers in manufacturing facilities and data centers benefit from reliable, selective protection. Feature: PXR20 LSIAM trip unit with Power Xpert Release compatibility. This advanced trip unit delivers calibrated protection with adjustable settings, enabling precise coordination and faster fault clearance. Business impact: enhanced selectivity minimizes unnecessary trips and streamlines commissioning in complex automation lines. Application: industrial automation cabinets and utility feeders requiring scalable protection management. Feature: Fixed horizontal mounting and substantial physical footprint. With dimensions of 16.3 in (depth) × 16.8 in (height) × 31.1 in (width) and a 237 lb weight, the breaker supports stable integration in large enclosures and retrofit projects. Business impact: predictable installation reduces field time and mechanical risk. Application: retrofit upgrades and new builds in space-constrained plant layouts. Feature: Comprehensive certifications and compliance. UL Listed, KEMA Certified, ANSI, CSA, Lloyd’s Register, CE Marked, plus additional certifications ensure regulatory alignment across regions. Business impact: lowers procurement risk and accelerates global supply chain approvals. Application: multinational facilities and projects with strict commissioning requirements. Feature: Documentation, support, and compatibility ecosystem. Access to application notes, manuals, and product guides (including ZSI, protective coordination, and PXr-related resources) supports rapid engineering adoption and ongoing maintenance. Business impact: reduces training time, minimizes errors, and extends asset life. Application: engineering teams deploying Magnum PXR protection across large-scale installations.

Get a Quick Quote for a Eaton MPS8503HEAXX2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS8503HEAXX2H? Enquire Now

FAQs

The MPS8503HEAXX2H is designed for seamless integration within Magnum PXR installations and is compatible with Power Xpert Release trip units. This facilitates coordinated protection across existing panelboards, enabling straightforward retrofits and scalable protection schemes without major enclosure or wiring changes.
The PXR20 LSIAM trip unit offers adjustable protection curves, enhanced coordination, and rapid fault isolation. It supports precise overcurrent protection for three-pole configurations, helping prevent nuisance trips while protecting downstream equipment in motor circuits and critical feeders.
This model carries UL Listed, KEMA Certified, ANSI, CSA Certified, Lloyd’s Register Certified, CE Marked, and other approvals. These certifications support compliance across North America, Europe, and key international markets, reducing procurement risk and facilitating multi-region project execution.
Yes. With its high interrupting capacity of 5000 A (ABCABC) and the PXR20 LSIAM trip unit, the breaker supports selective coordination in complex power distribution. Typical applications include main feeders and large motor circuits where precise tripping coordination minimizes outages and preserves critical loads.
Plan for fixed horizontal mounting in compatible enclosures, accounting for its 16.3 in depth, 16.8 in height, and 31.1 in width. Use the available manuals and zone selective interlocking resources to streamline commissioning, reduce field wiring time, and lower lifecycle costs through reliable protection and minimal unscheduled downtime.