Eaton MPS8503MEAXX2F Magnum LV breaker - 85 kAIC
Part Number: MPS8503MEAXX2F
Quick Summary
The Eaton Magnum low voltage power circuit breaker provides reliable overcurrent protection for large motor loads and distribution systems. Engineers often contend with nuisance trips and downtime when protection isn’t matched to system demand. This model carries CE Marked and UL Listed certifications, plus ANSI/CSA marks and additional KEMA, Lloyd’s Register, and DNV GL approvals to support global installations. Designed for motor-start protection and seamless integration with Power Xpert Protection Manager, it helps reduce downtime, streamline maintenance, and improve overall equipment effectiveness.
Product Information
Extended Description
MPS8503MEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 85 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8503MEAXX2F
UPC
786689629601
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked NEMA Compliant CCC Marked SABA Listed
Certifications
KEMA Certified ANSI CSA Certified Lloyd's Register Certified UL Listed ABS Certified DNV GL Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR20 LSIG ARMS
Number of poles
Three-pole
Rated uninterrupted current (Iu)
5000 A
Interrupt rating
85 kAIC
Interrupt rating
85 kAIC
Rated uninterrupted current (Iu)
5000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8503MEAXX2F
Eaton Specification Sheet - MPS8503MEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The 5000 A Iu capacity and an 85 kAIC interrupt rating deliver robust overcurrent protection for high-inrush applications, reducing unplanned outages and ensuring safer fault clearing for motor feeders and critical distribution trunks in manufacturing lines. Drawout vertical mounting with motorized racking speeds maintenance, minimizes live-exposure during replacement and supports safe servicing in panel boards and switchgear housings. The PXR20 LSIGAM trip unit provides LSIG protection and ARMS coordination, enabling selective tripping and arc-flash mitigation across downstream devices with easy configuration through the Magnum PXr ecosystem. A double standard frame and three-pole Magnum PXR design standardize installations, improving procurement efficiency and spare-parts availability across projects. Global certifications—UL Listed, CE Marked, ANSI/CSA, KEMA, Lloyd’s Register, DNV GL—support multinational deployments and compliance documentation, while compatibility with Power Xpert Protection Manager enhances monitoring and fault analysis for operators seeking real-time insight.
Get a Quick Quote for a Eaton MPS8503MEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8503MEAXX2F?
Enquire Now
FAQs
The MPS8503MEAXX2F uses a drawout vertical mounting with motorized racking, enabling safe, rapid replacement and alignment in Magnum panelboards. Its three-pole, double-standard frame design simplifies integration with existing Magnum PXR protection systems and Power Xpert Protection Manager, reducing commissioning time and enabling consistent maintenance workflows across multiple switchgear installations.
This unit provides a rated uninterrupted current (Iu) of 5000 A and an interrupt rating of 85 kAIC for reliable fault interruption. It is a three-pole Magnum PXR device with PXR20 LSIGAM trip unit, supporting motor-start protection and selective coordination for large motor feeders in industrial facilities.
Yes. The breaker carries multiple certifications including UL Listed, CE Marked, ANSI, CSA, KEMA, Lloyd’s Register, and DNV GL, along with NEMA compliance and CCC Marked status. This broad approvals portfolio supports international projects, cross-border manufacturing sites, and documentation required for global regulatory compliance.
The device is designed to work with Magnum PXR trip units and Power Xpert Protection Manager, enabling coordinated protection, real-time diagnostics, and remote configuration. This integration reduces downtime, streamlines fault analysis, and supports scalable protection architectures for evolving plant networks.
The drawout design and motorized racking minimize maintenance time and safety risk during breaker replacement. Availability of renewal parts and compatibility with standard Magnum components improve spare-part planning, while the strong certifications and global approvals simplify lifecycle management for multinational facilities.