The Eaton Magnum low voltage power circuit breaker is designed to protect industrial power distribution with fast, selective tripping. Engineers often struggle to balance rapid fault isolation with coordination across complex panels. This unit ships with CE Marked and UL Listed certifications, plus ANSI and KEMA clearance, delivering global compliance and rugged reliability. Powered by the PXR20 LSIAM trip unit, it supports Power Xpert protection and seamless integration with protection management systems for reduced downtime and optimized maintenance. Whether upgrading legacy panels or designing new machines, this breaker helps meet demanding uptime targets. Its triple-pole design and fixed vertical mounting simplify retrofit projects and field installation.
Product Information
Extended Description
MPS8503VEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 85 kA, Three-pole, Fixed vertical mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8503VEAXX2H
UPC
786689635633
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
Lloyd's Register Certified ANSI KEMA Certified UL Listed CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8503VEAXX2H
Eaton Specification Sheet - MPS8503VEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Power Xpert Release (PXR20 LSIAM) trip unit delivers precise, configurable protection for three-pole breakers. This feature improves selectivity across feeders, reduces nuisance trips, and shortens fault clearance times in crowded panels. In motor control centers and distribution boards, the PXR20 enables tailored curves and settings to match load profiles and code requirements. Three-pole, fixed vertical mounting provides a stable, space-efficient footprint for retrofit projects and new installations. This design simplifies alignment with bus sections and supports standard enclosures without custom adapters. The fixed orientation also eases wiring management, speeding field work and reducing setup risk. High fault capability is evident with 85 kA short-circuit rating and 5000 A interrupt rating, ensuring robust protection for demanding environments. Coupled with precise trip characteristics, you get fast isolation of faults, protecting downstream equipment and personnel while maintaining system uptime. Global compliance is demonstrated by CE Marked, UL Listed, ANSI, KEMA, and Lloyd's Register certifications, along with NEMA compliance for rugged conditions. These certifications simplify procurement and regulatory audits across regions, helping you consolidate vendors and reduce risk. Installation and integration are streamlined by compatibility with Eaton Power Xpert Protection Manager and related software. The unit ships with standard inputs and a user manual, and the PXR20 trip unit exposes settings that align with standard protection schemes, easing commissioning and ongoing diagnostics. For retrofit teams, the Magnum's generous footprint and 237 lb weight indicate a solid, heavy-duty clamp-in solution, while the 16.3 in length and 31.1 in width provide ample space for wiring and labeling.
Get a Quick Quote for a Eaton MPS8503VEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8503VEAXX2H?
Enquire Now
FAQs
The MPS8503VEAXX2H uses a three-pole, fixed vertical mounting configuration, designed for straightforward retrofit or new installations in standard panels. Allow clearances for wiring, plan for alignment with bus sections, and accommodate a robust 237 lb unit. Follow the included manual for terminal torque specs and the PXR20 trip unit commissioning steps to ensure proper protection coordination.
The PXR20 LSIAM trip unit provides precise, configurable protection curves enabling selective coordination across feeders. This reduces nuisance trips and shortens fault clearance times in complex panels. In practice, engineers can tailor settings to motor starting and protection needs, improving uptime while maintaining compliance with applicable standards.
Yes. The breaker is CE Marked and UL Listed, with ANSI, KEMA, and Lloyd’s Register certifications, plus NEMA compliance. This broad certification portfolio supports worldwide procurement, QA audits, and regulatory compliance, making it suitable for multinational installations and rigorous industrial environments.
Using Magnum PXR in an MCC enhances protection coordination, reduces unexpected outages, and speeds fault isolation. The robust 85 kA SCCR and 5000 A interrupt rating protect critical loads while the Power Xpert integration provides diagnostics for scheduled maintenance, lowering lifecycle costs and improving overall plant productivity.
The MPS8503VEAXX2H is designed to integrate with Eaton Power Xpert Protection Manager. Commissioning involves configuring the PXR20 trip unit, connecting to the protection manager, and using the included manuals for setup. This enables remote monitoring, event logging, and streamlined diagnostics to support proactive maintenance and faster response to faults.