Eaton MPS8504HEAXX2H Magnum LV Circuit Breaker - UL Listed
Part Number: MPS8504HEAXX2H
Quick Summary
The Eaton Magnum low voltage power circuit breaker protects critical distribution panels with precise fault isolation. Many engineers struggle with nuisance trips, limited protection coordination, and integrating protection devices into modern automation systems. UL Listed, CE Marked, and KEMA/Lloyd's Register certifications demonstrate global compliance and reliability in diverse environments. As part of the Magnum PXR family, this four-pole, fixed-horizontal unit supports selective coordination and scalable protection for high-current panels, while integration with Power Xpert Protection Manager enables centralized monitoring and faster diagnostics. This combination delivers reduced downtime, improved safety, and lower total cost of ownership for industrial facilities. Its rugged design is suited for harsh industrial environments and long service life.
Product Information
Extended Description
MPS8504HEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNABCABC), 85 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8504HEAXX2H
UPC
786689635770
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant SABA Listed CE Marked CCC Marked
Certifications
KEMA Certified Lloyd's Register Certified ANSI CSA Certified UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8504HEAXX2H
Eaton Specification Sheet - MPS8504HEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature → Business Impact → Application: The Magnum PXR electronic trip unit (PXR20 LSIAM) delivers precise protection settings that can be tailored to site conditions, enabling selective coordination across feeder circuits. This reduces nuisance trips and improves mean time between failures, lowering maintenance costs and unplanned downtime. In practice, engineers use the PXR20 to align protective curves with motor inrush and short-circuit profiles in panelboards and distribution blocks. Feature → Business Impact → Application: The four-pole, fixed-horizontal Magnum frame supports robust, space-efficient installation in standard low-voltage panels. The design simplifies bus-bar connections while maintaining rigid mechanical integrity, which shortens commissioning time and minimizes mis-wiring risk. Ideal for data centers, process lines, and machine builds requiring reliable, repeatable protection. Feature → Business Impact → Application: An 85 kA short-circuit current rating with a 5000 A frame (NNABCABC) offers substantial fault immunity for high-current loads, protecting equipment and shortening fault clearance times. Operators gain confidence in safety margins while preventing cascading outages in multi-busbar configurations. This is particularly valuable for motor starters, HVAC packs, and heavy-plant feeders. Feature → Business Impact → Application: Compliance footprint is broad: UL Listed, CE Marked, CCC Marked, along with KEMA and Lloyd's Register certifications. This simplifies global procurement and reduces the need for local re-certification, speeding project timelines and ensuring regulatory adherence in diverse geographies. The product also carries NEMA Compliance and SABA Listing for North American and international markets. Feature → Business Impact → Application: Resources and compatibility are robust: time-current curves, coordination papers, and installation guides are available for easy sizing and testing. Power Xpert Protection Manager software integration supports remote monitoring, trending, and alarm management, while renewal parts and accessories extend lifecycle. These factors translate to lower total cost of ownership and clearer maintenance planning. Feature → Business Impact → Application: In modern automation environments, engineers demand breakers that align with digital protection strategies and Industry 4.0 goals. The MPS8504HEAXX2H delivers not just protection, but data-enabled insights that support preventive maintenance and faster recovery after faults.
Get a Quick Quote for a Eaton MPS8504HEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8504HEAXX2H?
Enquire Now
FAQs
The MPS8504HEAXX2H is designed for industrial low-voltage distribution protection, typically installed in panels, motor control centers, and process lines to provide reliable fault isolation and selective coordination with the PXR20 trip unit.
Yes. The MPS8504HEAXX2H incorporates the Magnum PXR family with Power Xpert-compatible protection, enabling centralized monitoring, trending, and alarms through Power Xpert Protection Manager.
Key ratings include a four-pole configuration, 85 kA short-circuit current rating (SCCR), and blueprinted protection with a PXR20 LSIAM trip unit for tailored protection curves in LV power distribution.
The unit is UL Listed, CE Marked, and CCC Marked, with additional credentials such as KEMA Certified and Lloyd's Register Certified, supporting global procurement and regulatory compliance.
It features fixed horizontal mounting and a four-pole design suitable for standard panel spaces. The unit weighs 319 lb and has overall dimensions of about 16.3 in length, 16.8 in height, and 44.1 in width, requiring appropriate handling and space planning.