Eaton MPS85A4HEAXX2A Magnum LV Breaker - UL Listed
Part Number: MPS85A4HEAXX2A
Quick Summary
Eaton Magnum low-voltage power circuit breaker provides robust protection for industrial electrical feeders. Engineers often wrestle with nuisance trips, slow fault isolation, and costly downtime in large switchgear. This unit is ANSI, Lloyd's Register certified, UL listed, and CE marked to support global projects. With the PXR20 LSI trip unit and four-pole configuration, it delivers precise protection and reliable coordination. Its fixed horizontal mounting suits dense panels, while the 5000 A interrupting rating and 85 kA SCCR handle high fault currents. Together, these features translate to shorter outages, lower maintenance costs, and easier compliance across industries from manufacturing to data centers.
Product Information
Extended Description
MPS85A4HEAXX2A Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NABCNABC), 85 kA, Four-pole, Fixed horizontal mounting, PXR20 LSI trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85A4HEAXX2A
UPC
786689636029
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CE Marked CCC Marked SABA Listed
Certifications
ANSI Lloyd's Register Certified KEMA Certified UL Listed CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x32 22.06 1
Power Xpert Protection Manager x32 22.06 1
Eaton Specification Sheet - MPS85A4HEAXX2A
Eaton Specification Sheet - MPS85A4HEAXX2A
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: PXR20 LSI trip unit provides advanced protection logic and precise fault detection. Business Impact: Enhances selectivity and reduces nuisance trips, leading to improved equipment uptime and safer fault isolation. Application: Ideal for motor feeders and critical loads in manufacturing lines where downtime is costly and reliability is paramount. Feature: Four-pole design with fixed horizontal mounting offers stable, predictable operation in standard low-voltage panels. Business Impact: Simplifies installation and reduces panel space conflicts, enabling quicker commissioning. Application: Suitable for compact switchgear banks and retrofit projects where space optimization matters. Feature: 5000 A interrupting capacity with 85 kA SCCR delivers robust protection against high-energy faults. Business Impact: Improves system resilience, lowers risk of arc-flash events, and simplifies coordination with upstream protection. Application: Critical feeders and main buses in heavy industry and data-center infrastructure. Feature: Comprehensive certifications (UL Listed, CE Marked, ANSI, Lloyd's Register, etc.) mitigate procurement risk. Business Impact: Accelerates approvals for global projects and lowers compliance overhead. Application: Global deployments across regions with diverse regulatory requirements. Feature: Magnum PXR compatibility and fixed-mount integration streamline maintenance and serviceability. Business Impact: Reduces downtime during upgrades and simplifies spare-part management. Application: Panels and cabinets that require consistent protection with minimal maintenance.
Get a Quick Quote for a Eaton MPS85A4HEAXX2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS85A4HEAXX2A?
Enquire Now
FAQs
For seamless integration, ensure the MPS85A4HEAXX2A is mounted horizontally in a standard low-voltage cabinet, connected to the Power Xpert Protection Manager where available, and configured with the PXR20 LSI trip unit to establish proper selectivity. Verify busbar alignment, simultaneous phase connections, and confirm upstream protection settings to achieve coordinated tripping across feeders and main circuits. Always reference the latest Eaton installation guides and the PXR user manuals for sequence and safety procedures.
This breaker features a four-pole frame with a 5000 A interrupting rating and an 85 kA SCCR, designed for high-energy fault protection. The PXR20 LSI trip unit provides adjustable and precise protection curves, enabling selective coordination and reliable fault isolation. The unit is suitable for demanding industrial feeders and motor circuits, offering rapid fault clearing while minimizing collateral impact on surrounding equipment.
Yes. The Magnum design with PXR20 LSI trip, four-pole configuration, and high interrupting capacity makes it well-suited for data centers and motor feeders where uptime is critical. Its robust coordination capability helps prevent unnecessary outages, while UL and CE certifications facilitate global deployments. In data centers, reliable protection of feeders and IT infrastructure translates directly to improved service continuity.
The MPS85A4HEAXX2A carries UL Listed, CE Marked, ANSI, and Lloyd's Register certifications, among others, with additional approvals such as CSA, ABS, and DNV GL. Compliance with NEMA standards and CCC Marked status further supports international projects. These certifications reduce procurement risk and simplify cross-border installations in regulated environments.
Maintenance benefits stem from the PXR20 LSI trip unit’s reliability and the breaker’s robust build, which reduces nuisance trips and shortens fault-clearing times. The fixed horizontal mounting simplifies service access, while standardized spare parts and compatible protection software streamline updates. Over time, these factors contribute to lower downtime costs, reduced maintenance labor, and a favorable ROI for facilities with stringent availability requirements.