Eaton Magnum low voltage power circuit breaker provides robust overcurrent protection for industrial power distribution networks, enabling reliable operation in manufacturing, processing, and packaging facilities. Engineers often contend with nuisance trips and imperfect coordination that trigger unplanned outages, eroding safety margins and driving costly downtime. This model carries multiple certifications to support global installation, including SABA listing, CCC marking, and CE marking, complemented by NEMA compliance and UL Listed status for critical electrical environments. With the PXR20 LSIGAM trip unit for selective coordination and the option of Power Xpert Release integration, it delivers safer protection, easier fault discrimination, and lower maintenance costs across panel boards and machine controls.
Product Information
Extended Description
MPS85N3HEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (AABBCC), 85 kA, Three-pole, Fixed horizontal mounting, PXR20 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85N3HEAXX2F
UPC
786689636326
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
SABA Listed CCC Marked CE Marked NEMA Compliant
Certifications
Lloyd's Register Certified KEMA Certified ANSI UL Listed CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x32 22.06 1
Power Xpert Protection Manager x32 22.06 1
Eaton Specification Sheet - MPS85N3HEAXX2F
Eaton Specification Sheet - MPS85N3HEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Feature: The PXR20 LSIGAM trip unit provides selective coordination with adjustable protection to discriminate faults at the source. Business Impact: reduces nuisance trips, minimizes arc energy exposure, and shortens downtime for critical lines. Application: panel boards, motor control centers, and machine lines requiring precise fault discrimination. Feature: 85 kA interrupting capacity enables rapid interruption of large fault currents. Business Impact: protects downstream equipment, simplifies system coordination, and lowers replacement costs after faults. Application: heavy machinery, processing lines, and high-inrush environments. Feature: Three-pole, fixed horizontal mounting supports consistent installation within standard enclosures. Business Impact: reduces installation time, alignment errors, and commissioning risk. Application: retrofit or new-build assemblies in control panels and switchgear. Feature: Broad certifications including SABA Listed, CCC Marked, CE Marked, NEMA Compliant, UL Listed, and CSA Certified. Business Impact: streamlines procurement and regulatory compliance across global sites. Application: multinational facilities with diverse compliance requirements. Feature: Power Xpert Release trip-unit compatibility provides advanced protection management. Business Impact: enables faster fault isolation and simplified maintenance planning. Application: facilities leveraging Eaton protection-management ecosystems. Feature: Compact Magnum frame with fixed horizontal mounting supports efficient space utilization in existing layouts. Business Impact: optimizes panel density and reduces enclosure footprint. Application: new installations and upgrades in compact switchboards and MCCs.
Get a Quick Quote for a Eaton MPS85N3HEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS85N3HEAXX2F?
Enquire Now
FAQs
The MPS85N3HEAXX2F uses a three-pole configuration with fixed horizontal mounting designed for standard Magnum enclosures. Confirm enclosure width (31.1 in), height (16.8 in), and depth (16.3 in) to ensure a seamless fit and proper clearance for wiring and trip-unit access.
Key specifications include three-pole operation, 85 kA short-circuit rating, fixed horizontal mounting, PXR20 LSIGAM trip unit, and a weight of 237 lb with dimensions 16.3 in × 16.8 in × 31.1 in. It is UL Listed and CE Marked with NEMA compliance.
Yes. It carries SABA Listed, CCC Marked, CE Marked, NEMA Compliant, UL Listed, CSA Certified, and additional certifications from Lloyd’s, KEMA, DNV GL, and ABS, supporting global procurement and site audits.
The PXR20 LSIGAM unit enables selective coordination by accurately discriminating faults, reducing downstream trips, and enabling faster fault isolation. This improves safety and uptime, while simplifying maintenance in panel boards and MCCs.
By reducing nuisance trips through selective coordination and leveraging a durable, UL/CE-certified construction, maintenance planning becomes more predictable, downtime decreases, and lifecycle costs are lowered due to fewer unplanned outages and easier integration with protection-management systems.