Eaton MPS85N3WEAXX2C Magnum LV Circuit Breaker - UL Listed
Part Number: MPS85N3WEAXX2C
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial distribution panels in demanding factory environments. When panel testing or motor starts trigger nuisance trips, downtime and maintenance costs rise, eroding uptime and increasing spare-part consumption. UL Listed, CE marked, ANSI and CSA certified provide global compliance with industry standards and customer specifications. Designed for drawout vertical mounting and Power Xpert Release trip units, it supports scalable protection strategies and remote diagnostics through Power Xpert tools, offering clearer fault visibility and faster service, reducing total cost of ownership.
Product Information
Extended Description
MPS85N3WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (AABBCC), 85 kA, Three-pole, Drawout vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85N3WEAXX2C
UPC
786689636524
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked SABA Listed NEMA Compliant CE Marked
Certifications
Lloyd's Register Certified UL Listed ANSI KEMA Certified CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS85N3WEAXX2C
Eaton Specification Sheet - MPS85N3WEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: PXR20 LSIG trip unit delivers precise overcurrent protection and selectable coordination. Business Impact: minimizes nuisance trips and fault propagation, improving uptime and reducing unplanned maintenance. Application: ideal for motor control centers and machine panels where accurate tripping and fast fault isolation are critical. Feature: Drawout vertical mounting streamlines retrofit and field service. Business Impact: reduces commissioning time, minimizes panel downtime during maintenance, and simplifies alignment with existing bus bars. Application: retrofit projects in aging facilities and new-builds with standard frame footprints. Feature: 85 kA interrupting capacity across a 3-pole, double standard frame. Business Impact: supports high fault current environments common in heavy industries, improving selective coordination and safety. Application: switchgear, feeders, and motor feeders in manufacturing plants and process industries. Feature: Power Xpert Protection Manager and PXR20 LSIG integration. Business Impact: enables remote monitoring, diagnostics, and protection analytics, reducing on-site visits and accelerating fault resolution. Application: plant-wide protection architectures and centralized maintenance programs. Feature: Comprehensive certifications and compliance. Business Impact: simplifies procurement and regulatory approvals across regions, lowering supply-chain risk. Application: data centers, pharmaceutical plants, and energy-intensive facilities requiring CE, UL, ANSI, CSA, and other standards. Feature: Robust mechanical and electrical compatibility. Business Impact: standard frame, three-pole design, and drawout mounting support quick panel integration with minimal engineering changes. Application: new builds and retrofit projects across OEM panels, motor control centers, and switchgear.
Get a Quick Quote for a Eaton MPS85N3WEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS85N3WEAXX2C?
Enquire Now
FAQs
To install, ensure panel compatibility with drawout vertical mounting and a three-pole configuration. Position the breaker in the designated drawout frame, engage the bus bars, and secure with the appropriate mounting hardware. Attach the PXR20 LSIG trip unit, verify clearances, torque mounting fasteners to the manufacturer’s specification, and program surge and trip settings per NEC/IEEE guidelines. Conduct a functional test before commissioning.
The MPS85N3WEAXX2C provides an 85 kA short-circuit rating, suitable for demanding motor and feeder protection in industrial settings. With a three-pole design and drawout mounting, it supports effective coordination in switchgear and MCCs, reducing arc exposure and improving motor start protection. Always verify voltage, system fault levels, and coordination curves for specific motor load profiles.
Yes. The MPS85N3WEAXX2C uses a Power Xpert Release (PXR) trip unit that integrates with Power Xpert Protection Manager for centralized protection management, monitoring, and diagnostics. This enables remote fault analytics, settings optimization, and streamlined maintenance planning across plant-wide protection architectures.
The breaker carries UL Listed, CE Marked, ANSI, CSA, and other certifications (including Lloyd’s Register and KEMA). These credentials support regulatory compliance, international procurement, and safety approvals. For regulated industries such as data centers or chemical processing, these certifications simplify audits, supplier qualification, and cross-border installations.
The PXR20 LSIG trip unit enables precise protection coordination and remote diagnostics through Power Xpert tools, reducing on-site maintenance visits and accelerating fault resolution. Over time, this lowers total cost of ownership by minimizing unplanned outages, extending component life, and improving uptime for critical processes in manufacturing and utilities environments.