Eaton MPS85N3WEAXXSW Magnum LV breaker - UL Listed

Part Number: MPS85N3WEAXXSW
Manufacturer
Eaton
Part number
MPS85N3WEAXXSW

Quick Summary

The Eaton Magnum low voltage power circuit breaker MPS85N3WEAXXSW provides reliable overcurrent protection for industrial power distribution panels. Many teams struggle with slow commissioning and costly downtime when upgrading protection in existing switchgear. This unit carries UL Listed, CSA Certified, and CE Marked approvals with additional third‑party certifications (KEMA, Lloyd's Register, ABS, DNV GL) for cross‑industry reliability. With a robust drawout vertical mounting design and the option to upgrade to Power Xpert Release trip units, it supports efficient, compliant protection and simplified maintenance across plant assets.

Product Information

Extended Description

MPS85N3WEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (AABBCC), 85 kA, Three-pole, Drawout vertical mounting, No trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85N3WEAXXSW
UPC
786689636500
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
SABA Listed CE Marked NEMA Compliant CCC Marked
Certifications
ANSI UL Listed CSA Certified KEMA Certified Lloyd's Register Certified ABS Certified DNV GL Certified
Drawout vertical mounting enables easy access during inspections and rapid replacement in crowded panels, reducing maintenance time and labor costs while boosting uptime. In motor control centers and switchgear, the Magnum frame preserves fault protection in tight spaces and simplifies replacement without removing entire assemblies. The 85 kA short-circuit rating provides high fault tolerance, limiting equipment damage and unplanned downtime in high-energy processes and large motor drives. Three-pole protection delivers balanced phase protection for three-phase systems, improving reliability in industrial distribution networks. The option to upgrade to Power Xpert Release trip units offers future-proof protection, enabling selective coordination and enhanced fault isolation while minimizing downtime and training needs. Certified to UL, CSA, and CE with additional global certifications, this breaker meets regulatory requirements across multiple regions, reducing compliance risk and speeding project sign-off.

Get a Quick Quote for a Eaton MPS85N3WEAXXSW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS85N3WEAXXSW? Enquire Now

FAQs

The MPS85N3WEAXXSW uses a drawout vertical mounting, which simplifies removal and replacement without disturbing adjacent components. Ensure adequate clearance for racking and un-racking the unit, and plan for proper alignment with the bus bars and mounting rails. Verify panel space and heat dissipation to maintain performance in continuous operation.
The breaker offers an 85 kA short-circuit rating, providing high fault current tolerance to limit damage during faults. This is critical for facilities with heavy motor loads or high-energy processes, reducing the likelihood of cascading failures and enabling safer, faster fault clearing with upstream coordination.
Yes. The Magnum PXR family supports Power Xpert Release trip units, offering an upgrade path for selective coordination and advanced protection logic. When upgrading, ensure the panel wiring and space accommodate the trip unit interface and review configuration in collaboration with your protection manager.
This breaker is UL Listed and CSA Certified, with CE marking and additional third-party approvals from KEMA, Lloyd's Register, ABS, and DNV GL. These certifications cover global electrical safety, performance, and reliability requirements, helping you meet regulatory demands and customer specifications across regions.
Ideal for motor control centers, switchgear, and process plants requiring robust fault protection and long service life. Benefits include reduced downtime from rapid maintenance, improved safety with a drawout design, and future-ready upgrades to Power Xpert Release trip units. The result is lower maintenance costs, faster commissioning, and improved system reliability over the breaker’s lifecycle.