Eaton MPS85N4MEAXX2H Magnum LV Circuit Breaker - UL Listed

Part Number: MPS85N4MEAXX2H
Manufacturer
Eaton
Part number
MPS85N4MEAXX2H

Quick Summary

Eaton Magnum low voltage power circuit breaker is designed to protect industrial power distribution panels. It provides reliable protection for electrical distribution in harsh manufacturing and processing environments. Installing and maintaining oversized protective devices can lead to downtime and costly outages, so choosing a unit with precise protection and easy integration matters. This model is CE marked, UL Listed, and NEMA compliant, supporting regional codes and safe operation. Featuring a PXR20 LSIAM trip unit, four-pole construction, and motorized, drawout mounting, it enables accurate protection coordination while simplifying installation and future expansion. This combination delivers dependable uptime, safer operations, and reduced maintenance costs for your critical electrical infrastructure.

Product Information

Extended Description

MPS85N4MEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNAABBCC), 85 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85N4MEAXX2H
UPC
786689636685
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
UL Listed Lloyd's Register Certified ANSI KEMA Certified CSA Certified DNV GL Certified ABS Certified
Feature: Drawout vertical with motorized racking mounting. Business Impact: Speeds replacement, minimizes manual handling, and reduces maintenance window exposure. Application: Ideal for motor control centers and service entrances where fast, safe breaker racking is required. Feature: PXR20 LSIAM trip unit with Power Xpert protection logic. Business Impact: Delivers precise overcurrent protection, customizable trip settings, and improved selective coordination. Application: Suitable for complex distribution schemes where arc-flash risk and nuisance tripping must be controlled without compromising safety. Feature: Four-pole, double standard frame design. Business Impact: Enhances compatibility with common 3-phase systems and simplifies panel integration. Application: Fits broad switchgear and MCC configurations, supporting standardized protection across multiple feeders. Feature: High interrupting capacity (85 kA) and robust construction. Business Impact: Withstands high fault currents, reducing equipment damage and downstream outages. Application: Critical in heavy industrial plants, metal processing, and chemical facilities where fault currents can spike. Feature: Comprehensive certifications and documentation package. Business Impact: Accelerates procurement, audits, and regulatory compliance while providing clear installation guidance. Application: Useful for projects requiring UL/CE/NEMA compliance and traceable support materials. Insight: For engineers migrating from legacy breakers, the Magnum PXR platform offers familiar protection logic with enhanced diagnostics, helping teams reduce commissioning time and improve maintenance planning. Long-tail keywords embedded include low voltage circuit breaker with motorized racking, PXR20 trip unit, selective coordination, UL Listed protection, four-pole drawout breakers, and high interrupting capacity devices.

Get a Quick Quote for a Eaton MPS85N4MEAXX2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS85N4MEAXX2H? Enquire Now

FAQs

The MPS85N4MEAXX2H uses a drawout vertical mounting with a motorized racking system that simplifies insertion and removal. Ensure the breaker is seated in the switchgear frame, connect line and load terminals per the Eaton user manual MN013016EN, and enable motorized racking only after all safety interlocks are verified. This reduces time on site while preserving operator safety.
Verify catalog number MPS85N4MEAXX2H, four-pole configuration, 85 kA interrupting capacity, 16.3 in depth, 16.8 in height, 44.1 in width, and 319 lb weight. Confirm PXR20 LSIAM trip unit compatibility, drawout mounting, and that the panel or MCC frame supports a Magnum double standard frame unit with motorized racking.
Yes. The Magnum MPS85N4MEAXX2H with PXR20 LSIAM trip logic supports selective coordination strategies by enabling precise trip settings and coordination curves. When paired with correctly tuned upstream devices and proper device grouping, it improves fault isolation, reduces arc flash exposure, and optimizes uptime in motor-driven processes.
This unit is UL Listed, CE Marked, and NEMA Compliant, with additional certifications including ANSI, CSA, DNV GL, Lloyd's Register, KEMA, and ABS. The diverse certification set helps streamline procurement across regions and simplifies compliance during audits and installation in regulated industries.
Expect reduced downtime due to motorized racking, easier maintenance access, and longer service life from robust construction. The PXR20 trip unit provides diagnostic data and stable protection, enabling preventive maintenance and improved asset utilization. Overall, operators often see lower operating costs and faster mean time to repair (MTTR) when standardizing on this platform.