Eaton MPS85N4VEAXX2H Power Breaker - UL Listed
Part Number: MPS85N4VEAXX2H
Quick Summary
Eaton Magnum low voltage power circuit breaker protects electrical systems by interrupting fault currents in industrial switchgear. Manufacturers often struggle with nuisance trips and poor coordination, leading to unplanned downtime. The unit features a PXR20 LSIAM trip system and broad certification coverage, supporting global deployment. With fixed vertical mounting and a four-pole configuration, it enables robust, scalable protection for large feeders and panel boards. This solution integrates with Power Xpert protections for streamlined monitoring, lifecycle management, and easier field upgrades. It’s well suited for data centers, manufacturing plants, and complex distribution schemes seeking reliable, standards-compliant performance.
Product Information
Extended Description
MPS85N4VEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNAABBCC), 85 kA, Four-pole, Fixed vertical mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS85N4VEAXX2H
UPC
786689636159
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CCC Marked CE Marked SABA Listed
Certifications
ANSI Lloyd's Register Certified UL Listed CSA Certified KEMA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS85N4VEAXX2H
Eaton Specification Sheet - MPS85N4VEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature → Business Impact → Application: The MPS85N4VEAXX2H uses a four-pole, fixed-vertical Magnum PXR frame which simplifies panel integration and reduces installation risk, delivering consistent protection for feeders in heavy-duty environments. Benefit: faster commissioning and improved reliability in main distribution panels. Application: industrial plants and large switchgear assemblies where space and alignment are critical. Feature → Business Impact → Application: PXR20 LSIAM electronic trip unit enables zone selective interlocking and adjustable protection curves, delivering precise coordination to minimize downtime. Benefit: reduced nuisance trips and targeted fault isolation; Application: factories with complex feeders and critical motors. Feature → Business Impact → Application: high interrupting capacity of 85 kA and 5000 A fault-current rating supports demanding power distribution and short-circuit resilience. Benefit: safer start-ups and enhanced equipment protection; Application: data centers, process lines, and high-load panels. Feature → Business Impact → Application: broad certifications (UL Listed, CE Marked, ANSI Lloyd’s Register) ensure global compliance and audit-ready documentation. Benefit: easier cross-border deployment and supplier confidence; Application: multinational facilities and executive procurement. Feature → Business Impact → Application: availability of renewal parts and compatibility with Power Xpert Protection Manager for ongoing maintenance and visibility. Benefit: lower total cost of ownership and predictable upgrades; Application: long-life installations and asset-intensive environments.
Get a Quick Quote for a Eaton MPS85N4VEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS85N4VEAXX2H?
Enquire Now
FAQs
Yes. The MPS85N4VEAXX2H is a four-pole, fixed-vertical Magnum PXR frame designed for standard low voltage panels. It follows a fixed mounting footprint and matches common panelboard openings. Ensure adequate space for the four-pole unit and verify compatibility with the PXR20 LSIAM trip unit for proper coordination and protection.
Key specifications include a four-pole configuration with fixed vertical mounting, an 85 kA interrupting capacity, and a 5000 A fault-current rating (NNAABBCC). The PXR20 LSIAM electronic trip unit enables precise protection curves and zone selective interlocking. The unit supports UL Listed, CE Marked, and other major certifications to ease coordination with downstream protective devices.
Ideal for main distribution panels, switchgear, and motor feeder protection in industrial facilities. Its high interrupting capacity and four-pole design support power distribution in data centers and manufacturing lines. The PXR protection and compatibility with Power Xpert Protection Manager help optimize selective coordination and minimize downtime in complex electrical networks.
The breaker carries UL Listed, CE Marked, and ANSI Lloyd’s Register certifications, along with CSA, KEMA, ABS, DNV GL, and SABA Listed equivalents. These certifications support regulatory compliance across regions, aid supplier qualification, and simplify audits for multinational sites and projects.
Expected ROI comes from reduced nuisance trips, improved selective coordination, and extended asset life. Availability of renewal parts and integration with Power Xpert Protection Manager lowers maintenance costs and downtime. Regularly updating protection settings and leveraging documented manuals streamlines service tasks and supports faster fault diagnosis.