Eaton MPS8603GEAXX2F Magnum LV Circuit Breaker - UL Listed
Part Number: MPS8603GEAXX2F
Quick Summary
Eaton Magnum low voltage circuit breaker is designed to protect industrial power distribution and motor circuits in demanding equipment rooms. When short circuits or nuisance trips occur, unplanned downtime drains productivity and inflates maintenance costs. UL Listed, CE Marked, and NEMA Compliant certifications ensure global acceptance while the Magnum’s 6000 A interrupting capacity (ABCABC) and 85 kA fault current rating address demanding protection needs. With the Power Xpert Release PXR20 trip unit and a drawout vertical design with motorized racking, commissioning, maintenance, and system upgrades become safer and faster, delivering reliable protection and meaningful business value across mission-critical applications.
Product Information
Extended Description
MPS8603GEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (ABCABC), 85 kA, Three-pole, Drawout vertical with extensions and motorized racking mounting, PXR20 LSIGAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8603GEAXX2F
UPC
786689638573
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
SABA Listed CCC Marked CE Marked NEMA Compliant
Certifications
Lloyd's Register Certified KEMA Certified CSA Certified ANSI UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS8603GEAXX2F
Eaton Specification Sheet - MPS8603GEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature → Business Impact → Application: 6000 A interrupting capacity (ABCABC) with an 85 kA fault rating, coupled with a three-pole, double standard frame design. Business Impact: Robust protection for large motors and feeders reduces nuisance trips and costly downtime, extending equipment life and lowering maintenance costs. Application: Suitable for motor control centers and feeder panels in heavy industrial facilities. Feature → Business Impact → Application: Power Xpert Release PXR20 LSIGAM trip unit. Business Impact: Provides precise, configurable protection with compatibility for remote monitoring and protection coordination, enabling predictive maintenance. Application: Critical loads and automated lines where coordinated protection improves safety and uptime. Feature → Business Impact → Application: Drawout vertical mounting with extensions and motorized racking. Business Impact: Simplifies installation, field servicing, and asset replacement with minimal panel disruption. Application: Service-friendly in switchgear, distribution panels, and MCCs. Feature → Business Impact → Application: Comprehensive compliance and certifications including UL Listed, CE Marked, and NEMA Compliant. Business Impact: Reduces procurement risk and speeds project approvals in global deployments. Application: Global manufacturing environments and multi-site installations. Feature → Business Impact → Application: Compatibility with Power Xpert Protection Manager ecosystem. Business Impact: Enables centralized protection management, data analytics, and faster incident response. Application: Plants adopting integrated protection platforms for improved reliability.
Get a Quick Quote for a Eaton MPS8603GEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS8603GEAXX2F?
Enquire Now
FAQs
The breaker uses a drawout vertical mounting with extensions and motorized racking, enabling quick, tool-assisted insertion and removal. This design reduces maintenance time and improves safety during servicing and part replacement.
It is a three-pole device with 6000 A interrupting capacity (ABCABC) and an 85 kA fault current rating, equipped with the PXR20 LSIGAM trip unit for precise protection and coordination.
Yes. The MPS8603GEAXX2F uses the PXR20 trip unit, and it integrates with Power Xpert Protection Manager for centralized protection management, monitoring, and configuration.
The unit carries UL Listed, CE Marked, and NEMA Compliant certifications, along with additional approvals such as CSA, Lloyd's Register, KEMA, ABS, and DNV GL, reducing procurement risk in multi-region projects.
Ideal for motor control centers, heavy machinery feeders, and distribution panels where high interrupting capacity, reliable protection, and easy maintenance (via drawout racking) translate to lower downtime and improved process uptime.