Eaton MPS8603WEAXX2Q Magnum low voltage power circuit breaker - UL Listed

Part Number: MPS8603WEAXX2Q
Manufacturer
Eaton
Part number
MPS8603WEAXX2Q

Quick Summary

Eaton MPS8603WEAXX2Q Magnum low voltage power circuit breaker is designed to protect electrical distributions in industrial facilities. In demanding plants, nuisance trips and retrofit challenges complicate protection strategies, but this device delivers reliable protection with a scalable trip unit. UL Listed, CE Marked, and KEMA Certified ratings provide cross-border compliance and risk reduction for global installations. Its Magnum PXR frame and three-pole, drawout vertical mounting support streamlined maintenance, while the PXR25 LSI ARMS trip unit enables selective coordination. With a double standard frame and a 6000 A Iu / 85 kAIC capability, it supports high fault-current environments. This solution integrates with Power Xpert Protection Manager to monitor performance, helping procurement justify lifecycle costs and system availability.

Product Information

Extended Description

MPS8603WEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (ABCABC), 85 kA, Three-pole, Drawout vertical mounting, PXR25 LSIAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS8603WEAXX2Q
UPC
786689631864
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked SABA Listed NEMA Compliant CE Marked
Certifications
KEMA Certified UL Listed CSA Certified ANSI Lloyd's Register Certified ABS Certified DNV GL Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR25 LSI ARMS
Number of poles
Three-pole
Rated uninterrupted current (Iu)
6000 A
Interrupt rating
85 kAIC
Interrupt rating
85 kAIC
Rated uninterrupted current (Iu)
6000 A
Feature: PXR25 LSI ARMS trip unit enables advanced protection coordination. Business impact: reduces unplanned outages and damage by delivering precise tripping curves tailored to feeder configurations. Application: large distribution panels and process control systems. Feature: Magnum PXR frame with drawout vertical mounting. Business impact: simplifies installation, testing, and maintenance, decreasing panel downtime. Application: retrofit projects and new installations in controlled environments. Feature: Three-pole, double standard frame with 6000 A Iu rating and 85 kAIC interrupt capability. Business impact: supports high fault currents and robust feeder protection, enhancing system reliability and safety. Application: industrial plants, data centers, and heavy manufacturing. Feature: Comprehensive certifications (UL Listed, CE Marked, KEMA Certified, CSA, ANSI, Lloyd's, ABS, DNV GL). Business impact: accelerates procurement approvals and ensures global compliance. Application: multinational operations and field deployments. Feature: Compatibility with Power Xpert Protection Manager for monitoring and diagnostics. Business impact: enables predictive maintenance and reduces lifecycle costs. Application: fleet-wide asset management and performance optimization.

Get a Quick Quote for a Eaton MPS8603WEAXX2Q

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS8603WEAXX2Q? Enquire Now

FAQs

This three-pole unit uses a drawout vertical mounting in a double standard frame, making installation and maintenance straightforward in control panels and switchgear. Plan for adequate space in front of the panel for removal and testing, ensure compatibility with existing Magnum PXR trip units, and verify panel bus bar clearances to avoid contact during maintenance.
The breaker provides 6000 A rated uninterrupted current (Iu) and an 85 kAIC interrupt rating, enabling it to handle high fault currents without nuisance trips. With a three-pole configuration and PXR25 LSI ARMS trip unit, it supports selective tripping, improving feeder protection and minimizing collateral damage during faults.
Yes. The PXR25 LSI ARMS trip unit is designed for advanced protection coordination, enabling selective tripping across feeders. This reduces the scope of outages and improves system reliability, especially in complex distributions found in manufacturing and data center environments.
The unit carries UL Listed and CE Marked certifications, along with KEMA Certified status and CSA Certification. Additional approvals include ANSI, Lloyd's Register, ABS, and DNV GL, supporting global deployment and regulatory compliance across industries.
Plan for periodic verification of trip unit settings and mechanical operation, especially after firmware or protection-manager updates. The Power Xpert Protection Manager integration supports remote monitoring and diagnostics, enabling proactive maintenance and potentially extending service life while reducing unplanned downtime.