Eaton MPS86A4WEAXX2C Magnum LV Circuit Breaker - UL Listed

Part Number: MPS86A4WEAXX2C
Manufacturer
Eaton
Part number
MPS86A4WEAXX2C

Quick Summary

The Eaton MPS86A4WEAXX2C Magnum LV circuit breaker is a protection device for industrial power distribution. It features a four-pole configuration with a PXR20 LSIG trip unit, ideal for demanding panels and switchgear installations. Engineers often grapple with arc energy, coordination gaps, and maintenance downtime. This model addresses those challenges with a drawout vertical mounting design that streamlines installation and field replacement, reducing plant downtime. It carries CE Marked, NEMA Compliant, and UL Listed certifications, supporting global compliance and safety across facilities. By combining robust protection with Power Xpert Release capabilities, it enables safer maintenance, faster diagnostics, and lower lifecycle costs in control rooms and manufacturing floors. Magnum PXR‑specific benefits, including selective coordination, further improve system reliability.

Product Information

Extended Description

MPS86A4WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NABCNABC), 85 kA, Four-pole, Drawout vertical mounting, PXR20 LSIG trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86A4WEAXX2C
UPC
786689630553
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked CCC Marked NEMA Compliant SABA Listed
Certifications
CSA Certified Lloyd's Register Certified UL Listed ANSI KEMA Certified ABS Certified DNV GL Certified
Four-pole protection with the PXR20 LSIG trip unit enables selective coordination and precise overload detection. This reduces nuisance trips and shortens fault-clearing times, protecting transformers and motors alike. It’s ideal for large motor feeders in manufacturing lines and process automation panels. Drawout vertical mounting simplifies installation and field maintenance, allowing breakers to be swapped with minimal panel downtime. The design supports faster maintenance cycles, reducing labor costs during commissioning or upgrades in automation plants. 6000 A frame rating with 85 kA short-circuit capability provides robust protection for high-energy systems, facilitating safe integration with feeders, starters, and bus systems in heavy industry. Fan-cooled construction maintains performance in dense cabinets, and LSIG diagnostics provide visibility into system health for timely replacements. UL Listed, CE Marked, and NEMA compliant certifications support global deployment while enabling integration with Power Xpert Protection Manager for advanced monitoring and maintenance planning. Overall, the Magnum MPS86A4WEAXX2C reduces downtime, improves reliability, and lowers lifecycle costs by simplifying maintenance and improving fault isolation.

Get a Quick Quote for a Eaton MPS86A4WEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS86A4WEAXX2C? Enquire Now

FAQs

What to verify before installation includes ensuring proper de-energization, verifying clearance for the drawout mechanism, and confirming vertical mounting compatibility with the existing panel. Use correct wiring for the PXR20 LSIG trip unit and follow Eaton's installation guidance to minimize commissioning time and prevent mis-wiring that could affect coordination and protection.
Key performance specs include a 6000 A frame rating and an 85 kA short‑circuit capability, four-pole construction, and the PXR20 LSIG trip unit. These features deliver precise overload protection, fast fault clearing, and robust safety margins for high-energy industrial feeders in demanding environments.
Yes. The PXR20 LSIG trip unit supports selective coordination with a four-pole design, enabling precise fault isolation and minimizing the impact of faults on upstream equipment. For motor control centers, this enhances reliability and safety while reducing unnecessary outages during startup and fault events.
This model carries UL Listed, CE Marked, and NEMA compliance, along with CCC marking and several third‑party certifications (CSA, Lloyd's Register, ANSI, KEMA, ABS, DNV GL). These certifications support global deployment, regulatory adherence, and safer operation across diverse regional markets.
ROI benefits come from reduced downtime due to improved selective coordination and quicker fault isolation, easier maintenance with drawout mounting, and enhanced monitoring through Power Xpert Protection Manager. The result is higher equipment availability, lower maintenance labor costs, and longer lifecycle protection for critical manufacturing assets.